Displaying all 2 publications

Abstract:
Sort:
  1. Ng CT, Tan MP
    Age Ageing, 2013 Sep;42(5):561-6.
    PMID: 23864423 DOI: 10.1093/ageing/aft070
    Osteoarthritis and falls are common conditions affecting older individuals which are associated with disability and escalating health expenditure. It has been widely assumed that osteoarthritis is an established risk factor for falls in older people. The relationship between osteoarthritis and falls has, quite surprisingly, not been adequately elucidated, and published reports have been conflicting. Our review of the existing literature has found limited evidence supporting the current assumption that the presence of osteoarthritis is associated with increased risk of falls with suggestions that osteoarthritis may actually be protective against falls related fractures. In addition, joint arthroplasty appears to increase the risk of falls in individuals with osteoarthritis.
    Matched MeSH terms: Arthroplasty, Replacement/adverse effects
  2. Ruzaimi MY, Shahril Y, Masbah O, Salasawati H
    Med J Malaysia, 2006 Feb;61 Suppl A:21-6.
    PMID: 17042224
    Deep surgical site infection is a devastating consequence of total joint arthroplasty. The use of antibiotic impregnated bone cement is a well-accepted adjunct for treatment of established infection and prevention of deep orthopaedic infection. It allows local delivery of the antibiotic at the cement-bone interface and sustained release of antibiotic provides adequate antibiotic coverage after the wound closure. Preclinical testing, randomised and clinical trials indicate that the use of antibiotic-impregnated bone cement is a potentially effective strategy in reducing the risk of deep surgical site infection following total joint arthroplasty. The purpose of this study was to assess antibacterial activity of erythromycin and colistin impregnated bone cement against strains of organisms' representative of orthopaedic infections including Gram-positive and Gram-negative aerobic organisms: Staphylococcus aureus, coagulase-negative Staphylococci, Enterococcus sp., Proteus sp., Klebsiella sp., Pseudomonas sp., and Escherichia coli. Pre-blended Simplex P bone cement with the addition of erythromycin and colistin (Howemedica Inc) was mixed thoroughly with 20ml liquid under sterile conditions to produce uniform cylindrical discs with a diameter of 14mm and thickness of 2mm. 24-48 hour agar cultures of Staphylococcus aureus, coagulase-negative Staphylococci, Enterococcus sp.,Proteus sp., Klebsiella sp.,Pseudomonas sp., and Escherichia coli were used for the agar diffusion tests. The agar plates were streaked for confluent growth followed by application of erythromycin and colistin impregnated bone cement disc to each agar plate. The plates were incubated at 30 degrees C and examined at 24, 48, 72 hours, and four and five days after the preparation of the impregnated cement. The susceptibility of Staphylococcus aureus to the control discs was most clearly demonstrated showing a distinct zone of inhibition. The zone observed around coagulase-negative Staphylococci, Klebsiella sp., Pseudomonas sp., and Escherichia coli were also significant. However, there was no zone of inhibition or signs of antibacterial activity at the cemented surface were detected around discs with Enterococcus sp. and Proteus sp. The results showed that Simplex P bone cement with the addition of erythromycin and colistin was effective against most of the broad spectrum organisms encountered during total joint arthroplasty. The activity of Simplex P bone cement impregnated with erythromycin and colistin is mainly during the first 72 hours.
    Matched MeSH terms: Arthroplasty, Replacement/adverse effects
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links