Displaying publications 1 - 20 of 140 in total

Abstract:
Sort:
  1. Ong T, Vindlacheruvu M
    Age Ageing, 2023 Jun 01;52(6).
    PMID: 37389557 DOI: 10.1093/ageing/afad110
    The National Institute for Health and Care Excellence released its second update on hip fracture management in early 2023. First published in 2011, the last update was in 2017. The scope of this recent update focussed on surgical implants for hip fracture. This included recommendation to offer total hip replacements instead of hemiarthroplasty for displaced intracapsular hip fractures, and a move away from Orthopaedic Device Evaluation Panel rated implants to a more standardised consistent choice. Other recommendations such as the importance of multidisciplinary orthogeriatric care, early surgery and prompt mobilisation remain. As the literature surrounding hip fracture management continue to grow, guidance such as this needs to continue updating itself to ensure patients with hip fracture receive the best possible care.
    Matched MeSH terms: Arthroplasty, Replacement, Hip*
  2. Ardilla Hanim Abdul Razak, Ahmad Hafiz Zulkifly, Ramli Musa, Mohd Shukrimi Awang, Goh, Kian Liang
    MyJurnal
    Total knee arthroplasty represents a major advance in the treatment of
    degenerative joint disease. It provides excellent restoration of joint function and pain
    relief. The primary indication for total knee arthroplasty is to relieve pain caused by
    severe arthritis, with or without significant deformity. This study is to assess
    psychological impact pre and post arthroplasty. (Copied from article).
    Matched MeSH terms: Arthroplasty, Replacement, Knee
  3. Munjal A
    Malays Orthop J, 2018 Jul;12(2):62-64.
    PMID: 30112133 DOI: 10.5704/MOJ.1807.013
    Dislocation of meniscal bearing insert is a rare but well-recognised complication in meniscal bearing unicompartmental knee arthroplasty (UKA). On the other hand, fracture of meniscal bearing insert of phase III Oxford UKA has only been reported once in the current literature. The authors report a case of fracture and posterior dislocation of one of the fragments of the meniscal bearing insert in a mobile bearing medial UKA. The fracture was only diagnosed during the revision surgery. The posteriorly dislodged fragment was subsequently retrieved through the same skin incision and a new polyethylene insert of the same size was implanted.
    Matched MeSH terms: Arthroplasty, Replacement, Knee
  4. Harwant S
    Med J Malaysia, 2004 Dec;59 Suppl F:2.
    PMID: 15941152
    Matched MeSH terms: Arthroplasty, Replacement, Hip/instrumentation*
  5. Deshmukh RG, Thevarajan K, Kok CS, Sivapathasundaram N, George SV
    J Arthroplasty, 1998 Feb;13(2):197-9.
    PMID: 9526214
    Revision arthroplasty of the hip is often complicated by infection, bone loss, and perioperative fracture of the femur. A simple, inexpensive spacer that keeps tissue planes intact and prevents soft tissue contracture during the interoperative period of a 2-stage revision is described. This can provide intramedullary support to a fractured or weak femur and enable local antibiotic delivery, as well as permit limited mobilization of the patient. It can be easily fabricated during surgery using universally available materials and can be tailored for specific requirements. Such a spacer was used in 5 cases. The experience is presented, and the technique and pitfalls are discussed.
    Matched MeSH terms: Arthroplasty, Replacement, Hip/instrumentation*
  6. Aris A, Sulaiman S, Che Hasan MK
    Enferm Clin, 2021 04;31 Suppl 2:S10-S15.
    PMID: 33849138 DOI: 10.1016/j.enfcli.2020.10.006
    This study aimed to investigate the effects of music on physiological outcomes for post-operative TKA patients in the recovery unit. Fifty-six patients from Hospital Melaka were randomized equally into intervention (IG) and control groups (CG). IG received the usual care and listened to selected music for 60min, while the CG received only the usual care. Systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), respiration rate (RR) and oxygen saturation (SpO2) were measured on arrival and after 10, 20, 30, and 60min in the recovery unit. A significant difference between groups was observed in RR upon arrival (U=276.5, p=0.029) and after 10min (U=291, p=0.45). Meanwhile, there were significant differences in DBP (F=3.158, p=0.032), RR (χ2=15.956, p=0.003) and SpO2 (χ2=14.084, p=0.007) over time in the IG. Overall, listening to music immediately after TKA has an effect on DBP, RR, and SpO2.
    Matched MeSH terms: Arthroplasty, Replacement, Knee*
  7. Lee M, Ho JPY, Chen JY, Ng CK, Yeo SJ, Merican AM
    J Knee Surg, 2022 Feb;35(3):280-287.
    PMID: 32629512 DOI: 10.1055/s-0040-1713733
    BACKGROUND:  Restoration of the anatomical joint line, while important for clinical outcomes, is difficult to achieve in revision total knee arthroplasty (rTKA) due to distal femoral bone loss. The objective of this study was to determine a reliable method of restoring the anatomical joint line and posterior condylar offset in the setting of rTKA based on three-dimensional (3D) reconstruction of computed tomography (CT) images of the distal femur.

    METHODS:  CT scans of 50 lower limbs were analyzed. Key anatomical landmarks such as the medial epicondyle (ME), lateral epicondyle, and transepicondylar width (TEW) were determined on 3D models constructed from the CT images. Best-fit planes placed on the most distal and posterior loci of points on the femoral condyles were used to define the distal and posterior joint lines, respectively. Statistical analysis was performed to determine the relationships between the anatomical landmarks and the distal and posterior joint lines.

    RESULTS:  There was a strong correlation between the distance from the ME to the distal joint line of the medial condyle (MEDC) and the distance from the ME to the posterior joint line of the medial condyle (MEPC) (p 

    Matched MeSH terms: Arthroplasty, Replacement, Knee*
  8. Yeap SS, Abu Amin SR, Baharuddin H, Koh KC, Lee JK, Lee VKM, et al.
    BMC Musculoskelet Disord, 2021 Jun 04;22(1):514.
    PMID: 34088302 DOI: 10.1186/s12891-021-04381-8
    BACKGROUND: The 2013 Malaysian Clinical Practice Guidelines on the Management of Osteoarthritis (OA) recommend a linear step-up approach to manage knee OA. However, patients with knee OA often require a multimodal approach to address OA-related pain symptoms and functional limitations. This consensus aimed to provide doctors with an updated set of evidence-based, clinical experience-guided recommendations to manage knee OA.

    METHODS: A multi-speciality expert panel consisting of nine Malaysian physicians from different healthcare settings who manage a diverse OA patient population was convened. Using a combination of the ADAPTE process and modified Delphi method, the panel reviewed current evidence on the management of knee OA and synthesised a set of nine recommendations on the management of knee OA, supported by an algorithm that summarises the consensus' core messages.

    RESULTS: A multimodal intervention strategy is the mainstay of OA management and the choice of any single or multimodal intervention may vary over the course of the disease. Overall, a non-pharmacological core treatment set of patient education, weight loss and exercise is recommended for all patients. When pharmacotherapy is indicated, symptomatic slow-acting drugs for osteoarthritis are recommended at the early stage of disease, and they can be paired with physical therapy as background treatment. Concurrent advanced pharmacotherapy that includes non-steroidal anti-inflammatory drugs, intraarticular injections and short-term weak opioids can be considered if patients do not respond sufficiently to background treatment. Patients with severe symptomatic knee OA should be considered for knee replacement surgery. Management should begin with specific treatments with the least systemic exposure or toxicity, and the choice of treatment should be determined as a shared decision between patients and their team of healthcare providers.

    CONCLUSIONS: This consensus presents nine recommendations that advocate an algorithmic approach in the management of patients living with knee OA. They are applicable to patients receiving treatment from primary to tertiary care providers in Malaysia as well as other countries.

    Matched MeSH terms: Arthroplasty, Replacement, Knee*
  9. Ling HT, Kwan MK, Saw A, Choon DS
    Med J Malaysia, 2006 Aug;61(3):380-2.
    PMID: 17240598 MyJurnal
    The incidence of wound related complication following total knee arthroplasty is as high as 10%-20%. To perform total knee arthroplasty in a knee with extensive scarring around the knee can be a challenging task. We report a case of 55-year-old diabetic woman, who had total knee arthroplasty, performed two years after she had recovered from necrotizing fasciitis around the right knee. Understanding the vascular anatomy around the knee is of paramount importance in the planning of skin incision to ensure fewer wound related complications.
    Matched MeSH terms: Arthroplasty, Replacement, Knee*
  10. Siong FT, Kim TW, Kim SC, Lee ES, Jaffar MSA, Lee YS
    J Arthroplasty, 2020 02;35(2):380-387.
    PMID: 31587980 DOI: 10.1016/j.arth.2019.09.005
    BACKGROUND: The aims of this study were to (1) describe our functional stepwise multiple needle puncturing (MNP) technique as the final step in medial ligament balancing during total knee arthroplasty (TKA) and (2) evaluate whether this technique can provide sufficient medial release with safety.

    METHODS: A total of 137 patients with 212 consecutive knees who underwent TKAs with or without functional stepwise MNP of superficial medial collateral ligament was recruited in this prospective cohort. Eighty-one patients with 129 knees who performed serial stress radiographs were enrolled in the final assessment. Superficial medial collateral ligament was punctured selectively (anteriorly or posteriorly or both) and sequentially depending on the site and degree of tightness. Mediolateral stability was assessed using serial stress radiographs and comparison was performed between the MNP and the non-MNP groups at postoperative 6 months and 1 year. Clinical outcomes were also evaluated between 2 groups.

    RESULTS: Fifty-five TKAs required additional stepwise MNP (anterior needling 19, posterior needling 3, both anterior and posterior needling 33). Preoperative hip-knee-ankle angle and the difference in varus-valgus stress angle showed significant difference between the MNP and the non-MNP groups, respectively (P = .009, P = .037). However, there was no significant difference when comparing the varus-valgus stress angle between the MNP and the non-MNP groups during serial assessment. Clinical outcomes including range of motion also showed no significant differences between the 2 groups.

    CONCLUSION: Functional medial ligament balancing with stepwise MNP can provide sufficient medial release with safety in TKA with varus aligned knee without clinical deterioration or complication such as instability.

    LEVEL OF EVIDENCE: Level II, Prospective cohort study.

    Matched MeSH terms: Arthroplasty, Replacement, Knee*
  11. Norhamdan, M.Y., Damrudi, M., Santhna, L.P.
    Medicine & Health, 2015;10(1):66-79.
    MyJurnal
    Pain is an unpleasant sensation that can cause physical and psychological problems for the patient. Despite the pharmacological intervention for reducing pain, it remains as an issue after surgery. Music therapy as non-pharmacological intervention can effect post-operative pain and patients’ requirement of analgesics. The purpose of this study was to determine effect of music therapy on pain after elective total knee replacement (TKR) surgery. This study compared analgesics consumption by patients post-operatively for five days. A Quasi-experimental design with convenience sample of patient with a mean of 64.35 (49-76) who underwent TKR in UKM Medical Centre from May to December 2012 was used. Forty patients were randomly assigned in one of the two groups using a sealed-envelope technique. The experimental group listened to music for five days post-operatively and were on analgesics and control group were treated with pharmacological intervention only. Pain was measured by McGill Pain Questionnaire-Short Form (MPQ-SF) for patient on bed rest on day one, day three and day five post-operatively. Statistical (Mann- Whitney) findings between groups showed the experimental group significantly had less pain on day one and day five rather than the control group at 0.05 level using Pain Rating Intensity (PRI), Visual Analogue Scale (VAS) and Present Pain Intensity (PPI). Statistical (Friedman) tests within group showed that the patient had significantly decreased pain over time at level 0.05 using PRI, VAS and PPI. Statistical (Mann- Whitney) tests revealed that there was no significant difference when using analgesics between the two groups in five days post-operatively at milligram but comparing median showed experimental group used less analgesic than control group. Music therapy is simple, available, save and cheap effective intervention for pain management post-operatively. Pain management is one of the key roles of nursing and nurses can use music therapy as a simple intervention to reduce pain.
    Matched MeSH terms: Arthroplasty, Replacement, Knee*
  12. Hafizh M, Soliman MM, Qiblawey Y, Chowdhury MEH, Islam MT, Musharavati F, et al.
    Biosensors (Basel), 2023 Jan 02;13(1).
    PMID: 36671914 DOI: 10.3390/bios13010079
    In this paper, a surface acoustic wave (SAW) sensor for hip implant geometry was proposed for the application of total hip replacement. A two-port SAW device was numerically investigated for implementation with an operating frequency of 872 MHz that can be used in more common radio frequency interrogator units. A finite element analysis of the device was developed for a lithium niobate (LiNBO3) substrate with a Rayleigh velocity of 3488 m/s on COMSOL Multiphysics. The Multiphysics loading and frequency results highlighted a good uniformity with numerical results. Afterwards, a hip implant geometry was developed. The SAW sensor was mounted at two locations on the implant corresponding to two regions along the shaft of the femur bone. Three discrete conditions were studied for the feasibility of the implant with upper- and lower-body loading. The loading simulations highlighted that the stresses experienced do not exceed the yield strengths. The voltage output results indicated that the SAW sensor can be implanted in the hip implant for hip implant-loosening detection applications.
    Matched MeSH terms: Arthroplasty, Replacement, Hip*
  13. Chee, E.K., Ewe, T.W.
    Malays Orthop J, 2010;4(2):0-0.
    MyJurnal
    In total knee arthroplasty, mechanical alignment guides have improved the accuracy of implant alignment, but errors are not uncommon. In the present study, an image-free computer-assisted navigation system was used to analyse the accuracy of an extramedullary (tibial) alignment system, which is based on predetermined, fixed anatomical landmarks. Comparisons were made between two surgeons, with different levels of competency in order to determine if experience affected the accuracy of extramedullary tibial jig placement, in either the coronal and sagittal planes or both planes. The results showed that the accuracy of the extramedullary tibial alignment system, in the coronal plane (in up to 80-87% of cases) was much better than for posterior slope, and sagittal plane. Surgeon experience was not a significant factor.
    Matched MeSH terms: Arthroplasty, Replacement, Knee
  14. Sivananthan, K., Drabu, K.J.
    Malays Orthop J, 2009;3(1):42-45.
    MyJurnal
    The number of hip replacement procedures in the United States is expected to increase four-fold by 2030. Younger patients, those under 65 years old, are expected to account for 53% of hip replacements in 2030, compared to 44% in 2005. As midterm review results are becoming available worldwide now, the problem that perplexes surgeons is the alteration of limb length which has been an ancillary goal of Total Hip Replacements. The lack of modularity in neck lengths and offsets in resurfacing arthroplasty clearly limits the change in limb lengths achievable for the hip. The goal of this study is to scrutinize the various parameters that affect implant seating in resurfacing arthroplasty and to determine the alteration of limb length achievable during surgery.
    Matched MeSH terms: Arthroplasty, Replacement, Hip
  15. Ewe, T.W., Ang, H.L., Chee, E.K., Ng, W.M.
    Malays Orthop J, 2009;3(2):24-28.
    MyJurnal
    Current available implants for total knee replacement are based on the mormphometry of the Caucasian knee. We believe there are significant morphometric differences in the Asian knee that will be relevant in future implant designs. Sixty-nine consecutive patients (80 knees) underwent computer navigated primary total knee arthroplasty. The anterior-posterior (AP) length, and the medial-lateral (ML) width of the distal femur, were analyzed, with respect to the final sizing details of four implants (femoral component) commonly used locally. The mean AP length was 59.9 (SD4.8) mm, and the mean ML width was 65.0 (SD 5.0) mm. The overall mean aspect ratio (ML/AP) was 1.09 (SD 0.07). The mean aspect ratio for females was 1.08 (SD 0.07). Both were smaller than the aspect ratio of the implants - which ranged from 1.11 to 1.13. All four implants tend to overhang at the medial-lateral width of the distal femur. This is more obvious in females. Future implant designs should provide more ML wdth sizes for a given AP length, in addition to gender differences, for this population.
    Matched MeSH terms: Arthroplasty, Replacement, Knee
  16. Lim, Chia Hua, Jacob, V.A., Premchandran, N.
    MyJurnal
    The present concepts in Total Hip Arthroplasty advocate mechanical cement interlock
    with trabecular bone utilising the third-generation cementing technique. However, the
    force generated can easily reach peak pressure of 122 kPa to 1500 kPa, leading to
    extrusion of cement through nutrient foramina into femoral cortex into nutrient vessels,
    henceforth the retrograde arteriovenogram. (Copied from article).
    Matched MeSH terms: Arthroplasty, Replacement, Hip
  17. Kamaruzaman H, Kinghorn P, Oppong R
    BMC Musculoskelet Disord, 2017 05 10;18(1):183.
    PMID: 28486957 DOI: 10.1186/s12891-017-1540-2
    BACKGROUND: The primary purpose of this study is to assess the existing evidence on the cost-effectiveness of surgical interventions for the management of knee and hip osteoarthritis by systematically reviewing published economic evaluation studies.

    METHODS: A systematic review was conducted for the period 2004 to 2016. Electronic databases were searched to identify both trial and model based economic evaluation studies that evaluated surgical interventions for knee and hip osteoarthritis.

    RESULTS: A total of 23 studies met the inclusion criteria and an assessment of these studies showed that total knee arthroplasty (TKA), and total hip arthroplasty (THA) showed evidence of cost-effectiveness and improvement in quality of life of the patients when compared to non-operative and non-surgical procedures. On the other hand, even though delaying TKA and THA may lead to some cost savings in the short-run, the results from the study showed that this was not a cost-effective option.

    CONCLUSIONS: TKA and THA are cost-effective and should be recommended for the management of patients with end stage/severe knee and hip OA. However, there needs to be additional studies to assess the cost-effectiveness of other surgical interventions in order for definite conclusions to be reached.
    Matched MeSH terms: Arthroplasty, Replacement, Hip/economics*; Arthroplasty, Replacement, Knee/economics*
  18. Surinder S, George P
    Med J Malaysia, 2017 02;72(1):71-72.
    PMID: 28255148 MyJurnal
    Fracture of hip prostheses is a rare occurrence. A case of bilateral hip prostheses fracture is described here. The need to follow-up and remain vigilant post hip replacement is highlighted.
    Matched MeSH terms: Arthroplasty, Replacement, Hip
  19. Sa-Ngasoongsong P, Chulsomlee K, Wongsak S, Suphachatwong C, Kawinwonggowit V
    Malays Orthop J, 2016 Nov;10(3):52-55.
    PMID: 28553451 DOI: 10.5704/MOJ.1611.012
    Patellar fracture after total knee replacement (TKR) is one of the challenging problems in periprosthetic fracture. Open reduction with internal fixation (ORIF), as tension band wiring (TBW), usually required in cases with extensor mechanism disruption. However, many studies reported a high failure rate after using this technique. In this report, we presented an interesting case of periprosthetic patellar fracture after TKR with TBW failure that was successfully treated with double non-locking reconstruction plates fixation and TBW augmentation.
    Matched MeSH terms: Arthroplasty, Replacement, Knee
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links