Displaying all 3 publications

Abstract:
Sort:
  1. Saw HS, Grieve AW, Singham KT, Delilkan AE
    Med J Malaysia, 1977 Sep;32(1):63-6.
    PMID: 609348
    Matched MeSH terms: Aortic Coarctation/surgery
  2. Adeeb SMSJ, Leman H, Sallehuddin A, Yakub A, Awang Y, Alwi M
    Med J Malaysia, 2004 Mar;59(1):11-4.
    PMID: 15535329
    This retrospective study illustrates our approach to this problem over the years, from performing subclavian flap aortoplasty initially to the more accepted procedure now, which is resection and end-to-end anastomosis. Coarctation of aorta in our population is seen in a varying age groups and are also associated with other cardiac anomalies including both acyanotic and cyanotic congenital cardiac defects. Therefore a wide variety of surgical procedures were performed including resection of the coarcted segment and end-to-end anastomosis, subclavian flap aortoplasty, patch aortoplasty and synthetic tube graft interposition. Subclavian flap aortoplasty is not widely practised anymore in favour of resection with end-to-end anastomosis. Fifty four point four percent of patients had isolated coarctation, 10.5% had associated valvular defects, 28.1% had other simple congenital defects and 7.0% had associated complex cyanotic congenital defects. Perioperative mortality was 5.26% and is correlated with the younger age of patients at time of surgery and severity of cardiac failure at time of presentation. We did not see any difference in mortality for patients with complex congenital disease or between the different surgical procedures. However, we did find that in the early period when resection with end-to-end anastomosis was performed, there was a significantly higher incidence of morbidities.
    Matched MeSH terms: Aortic Coarctation/surgery*
  3. Promphan W, Han Siang K, Prachasilchai P, Jarutach J, Makonkawkeyoon K, Siwaprapakorn W, et al.
    Catheter Cardiovasc Interv, 2020 09 01;96(3):E310-E316.
    PMID: 32299151 DOI: 10.1002/ccd.28892
    OBJECTIVES: To assess feasibility and early outcomes of using BeGraft Aortic stent in the treatment of aortic coarctation (CoA).

    BACKGROUND: BeGraft Aortic stent (Bentley InnoMed, Hechingen, Germany) allows large postdilation diameter up to 30 mm. With availability of lengths of 19-59 mm and lower stent profile, they can be used in native and recurrent CoA in adults and in pediatric patients.

    MATERIALS AND METHODS: This is a multicentre retrospective analysis of 12 implanted BeGraft Aortic stents in CoA between May 2017 and April 2019.

    RESULTS: Twelve patients aged 7.7-38 years (median 18.3 years) with body weight of 19.9-56 kg (median 45.5 kg). Eight patients (66%) had native juxtaductal CoA while four had recurrent CoA after previous surgical or transcatheter treatments. The stents were implanted successfully in all the patients with no serious adverse events. The length of the stents ranged from 27 to 59 mm and the implanted stent diameter varied from 12 to 18 mm. The median intraprocedural CoA pressure gradient decreased from 25 mmHg (range 16-66 mmHg) to 2 mmHg (range 0-13 mmHg). The mean follow-up duration was 10.2 months. Two patient (16.6%) had residual stent narrowing requiring staged redilation. One patient (8%) had pseudoaneurysm formation at 1 year cardiac CT follow-up.

    CONCLUSIONS: The BeGraft Aortic stent may be considered to be safe and effective in the short term in treatment of CoA from childhood to adulthood. Long-term follow-up is needed.

    Matched MeSH terms: Aortic Coarctation/surgery*
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links