  1. Zucchelli G, Chun KRJ, Khelae SK, Földesi C, Kueffer FJ, van Bragt KA, et al.
    J Interv Card Electrophysiol, 2023 Apr;66(3):711-722.
    PMID: 36331681 DOI: 10.1007/s10840-022-01388-6
    BACKGROUND: Cryoballoon ablation (CBA) is an effective first-line treatment for symptomatic atrial fibrillation (AF), as recently demonstrated by three randomized trials. This sub-analysis of the Cryo Global Registry aims to examine current clinical practices of first-line CBA.

    METHODS: AF patients treated with first-line CBA were compared to CBA in antiarrhythmic drug (AAD)-refractory patients at 12 months. Efficacy was examined using time-to-first atrial arrhythmia recurrence following a 90-day blanking period. Healthcare utilization was evaluated by repeat ablations and hospitalizations. Disease burden was examined by assessing quality of life (QOL) and patients' reporting of symptoms.

    RESULTS: Of 1394 patients, 433 (31.1%) were treated with first-line CBA, which was more frequent in high-volume centers. Serious procedure-related adverse event rates were similar. Efficacy at 12 months was higher in the first-line group (87.8 vs. 81.6%, HRunadj 0.64 (95% CI 0.47-0.88); p 

  2. Scazzuso F, Ptaszyński P, Kaczmarek K, Chun KRJ, Khelae SK, Földesi C, et al.
    J Interv Card Electrophysiol, 2024 Apr;67(3):493-501.
    PMID: 37505337 DOI: 10.1007/s10840-023-01582-0
    BACKGROUND: Cryoballoon ablation is a well-established anatomical approach for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Although widely adopted, regional variations in standards of care have not been well characterized.

    METHODS: Patients with AF were enrolled in the Cryo Global Registry (NCT02752737) from May 2016 to Sept 2021 at 128 sites in 37 countries and treated with cryoballoon ablation according to local clinical practice. Baseline patient and procedural characteristics were summarized for 8 regions (Central Asia & Russia, East Asia, Europe, Middle East, North America, South Africa, South America, and Southeast Asia). Serious procedure-related adverse events (SAEs) were evaluated in a subset of patients with ≥ 7 days of follow-up.

    RESULTS: A total of 3,680 patients undergoing initial PVI for AF were included. Cryoballoon ablation was commonly performed in patients with paroxysmal AF. Mean age ranged from 47 ± 12 years in the Middle East to 64 ± 11 years in East Asia. Mean procedure time was ≤ 95 min in all regions. Average freeze duration ranged from 153 ± 41 s in Southeast Asia to 230 ± 29 s in Central Asia & Russia. Acute procedural success was ≥ 94.7% in all geographies. In 3,126 subjects with ≥ 7 days of follow-up, 122 procedure-related SAEs were reported in 111 patients (3.6%) and remained low in all regions. One procedure-related death was reported during data collection.

    CONCLUSIONS: Despite regional variations in patient selection and procedural characteristics, PVI using cryoballoon ablation was performed with high acute success and short procedural times around the world.

    CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT02752737.