Displaying all 7 publications

Abstract:
Sort:
  1. Abubakar A, Zin HM
    Biomed Phys Eng Express, 2020 Nov 09;6(6).
    PMID: 35102003 DOI: 10.1088/2057-1976/abc635
    The purpose of this study is to develop a method for characterisation of time-of-flight (ToF) imaging system for application in deep inspiration breath-hold radiotherapy (DIBH-RT). The performance of an Argos 3D P330 ToF camera (Bluetechnix, Austria) was studied for patient surface monitoring during DIBH-RT using a phantom to simulate the intra-patient and inter-patient stability of the camera. Patient setup error was also simulated by positioning the phantom at predefined shift positions (2, 5 and 10 mm) from the isocentre. The localisation accuracy of the phantom was measured using ToF imaging system and repeated using CBCT imaging alone (CBCT) and simultaneously using ToF imaging during CBCT imaging (ToF-CBCT). The mean and SD of the setup errors obtained from each of the imaging methods were calculated. Student t-test was used to compare the mean setup errors. Correlation and Bland-Altman analysis were also performed. The intra-and inter-patient stability of the camera were within 0.31 mm and 0.74 mm, respectively. The localisation accuracy in terms of the mean ±SD of the measured setup errors were 0.34 ± 0.98 mm, 0.12 ± 0.34 mm, and -0.24 ± 1.42 mm for ToF, CBCT and ToF-CBCT imaging, respectively. A strong correlation was seen between the phantom position and the measured position using ToF (r = 0.96), CBCT (r = 0.99) as well as ToF-CBCT (r = 0.92) imaging. The limits of agreement from Bland Altman analysis between the phantom position and ToF, CBCT and ToF-CBCT measured positions were -1.52, 2.31 mm, -0.55, 0.78 mm; and -3.03, 2.55 mm, respectively. The sensor shows good stability and high accuracy comparable to similar sensors in the market. The method developed is useful for characterisation of an optical surface imaging system for application in monitoring DIBH-RT.
  2. Wong JHD, Zin HM, Pawanchek M, Ng KH
    Phys Med, 2019 Nov;67:40-49.
    PMID: 31669669 DOI: 10.1016/j.ejmp.2019.10.019
    OBJECTIVE: Medical physics in Malaysia is still considered a young profession. This workforce survey aims to understand the status, aspirations, motivation and experiences of medical physicists (MPs) in the country. A subsection of this survey also aims to understand the role of women.

    METHOD: A survey was carried out between April 20 and May 30, 2018 by a working group under the Medical Physics Division of the Malaysian Institute of Physics (IFM). The survey form was designed using Google Form and sent to various public and private institutions nationwide that employed MPs registered with IFM.

    RESULTS: A total of 106 responses (28% men and 72% women) were analysed. This represented 30% of the medical physics workforce. Majority of them had postgraduate degrees, but their clinical training is mostly obtained on the job with no certification. The number of low-ranking female MPs was disproportionately high. MPs worked long hours and achieving work-life balance (WLB) was a challenge. Factors that improved their WLB included working close to home, having a supportive manager and flexible working hours. Most MPs aspired to become professional and mentor younger compatriots, besides contributing to patient care and research. Gender discrimination was reportedly low.

    CONCLUSION: Medical physics in Malaysia is growing and has a strong representation of women. In future, they would probably take over the top management from their male counterparts, whose number had stagnated. A united effort was essential to set up a proper clinical training system to train clinically qualified MPs.

  3. Mohyedin MZ, Zin HM, Abubakar A, Rahman ATA
    Phys Eng Sci Med, 2024 Apr 18.
    PMID: 38634981 DOI: 10.1007/s13246-024-01418-9
    Modern radiotherapy techniques have advanced and become more sophisticated. End-to-end 3D verification of the complex radiotherapy dose distribution in an anthropomorphic phantom can ensure the accuracy of the treatment delivery. The phantoms commonly used for dosimetry are homogeneous solid water phantom which lacks the capability to measure the 3D dose distribution for heterogeneous tissues necessary for advanced radiotherapy techniques. Therefore, we developed an end-to-end 3D radiotherapy dose verification system based on MAX-HD anthropomorphic phantom (Integrated Medical Technologies Inc., Troy, New York) with bespoke intracranial insert for PRESAGE® dosimeter. In this study, several advanced radiotherapy treatment techniques of various levels of complexity; 3D-CRT, IMRT and VMAT treatment, were planned for a 20 mm diameter of a spherical target in the brain region and delivered to the phantom. The dosimeters were read out using an in-house developed optical computed tomography (OCT) imaging system known as 3DmicroHD-OCT. It was found that the measured dose distribution of the PRESAGE® when compared with the measured dose distribution of EBT film and Monaco TPS has a maximum difference of less than 3% for 3D-CRT, IMRT and VMAT treatment plans. The gamma analysis results of PRESAGE® in comparison to EBT film and Monaco TPS show pass rates of more than 95% for the criteria of 3% dose difference and 3 mm distance-to-agreement. This study proves the capability of PRESAGE® and bespoke MAX-HD phantom in conjunction with the 3DmicroHD-OCT system to measure 3D dose distribution for end-to-end dosimetry verification.
  4. Hizam DA, Jong WL, Zin HM, Ng KH, Ung NM
    Med Dosim, 2021 04 08;46(3):310-317.
    PMID: 33838998 DOI: 10.1016/j.meddos.2021.03.003
    Intensity-modulated radiotherapy (IMRT) treatment planning for head and neck cancer is challenging and complex due to many organs at risk (OAR) in this region. The experience and skills of planners may result in substantial variability of treatment plan quality. This study assessed the performance of IMRT planning in Malaysia and observed plan quality variation among participating centers. The computed tomography dataset containing contoured target volumes and OAR was provided to participating centers. This is to control variations in contouring the target volumes and OARs by oncologists. The planner at each center was instructed to complete the treatment plan based on clinical practice with a given prescription, and the plan was analyzed against the planning goals provided. The quality of completed treatment plans was analyzed using the plan quality index (PQI), in which a score of 0 indicated that all dose objectives and constraints were achieved. A total of 23 plans were received from all participating centers comprising 14 VMAT, 7 IMRT, and 2 tomotherapy plans. The PQI indexes of these plans ranged from 0 to 0.65, indicating a wide variation of plan quality nationwide. Results also reported 5 out of 21 plans achieved all dose objectives and constraints showing more professional training is needed for planners in Malaysia. Understanding of treatment planning system and computational physics could also help in improving the quality of treatment plans for IMRT delivery.
  5. Abdullah R, Appalanaido GK, Shukor SA, Zin HM, Abd Aziz MZ, Ishak N
    Rep Pract Oncol Radiother, 2021;26(6):892-898.
    PMID: 34992860 DOI: 10.5603/RPOR.a2021.0105
    Background: This dosimetric study compared lateral wedge with medial only cardiac shielding (LEMONADE) technique, for left chest wall (LCW) irradiation against three other commonly used techniques.

    Materials and methods: Dosimetric parameters of 22 consecutive LBC patients treated using the P1 (LEMONADE technique) were compared with 3 other virtually reconstructed plans : no cardiac shielding with paired wedges; P2 (paired wedges and medial only Y-direction shielding) and P3 (paired wedges and bilateral Y-direction shielding).

    Results: P1 showed better target volume (TV) coverage with the mean 90% isodose coverage of 85.59% ± 5.44 compared to 78.90% ± 8.59 and 74.22% ± 9.50 for P2 and P3, respectively. Compared to no cardiac shielding, for a 4.65% drop in TV coverage the V26Gy of heart dropped from 6.68% to a negligible 0.85% for P1. TV receiving < 30Gy is also significantly lesser for P1 compared to P2 and P3 (5.42% vs 10.64% and 15.8%), whilst there is a small difference of 2.75% between no cardiac shielding and P1.

    Conclusion: With the improvement in BC survival rate, cardiac toxicity associated with adjuvant irradiation for LBC is a major concern. P1 (LEMONADE) technique has a good compromise between cardiac sparing and target coverage and should suffice for most LCW irradiations. Furthermore, the LEMONADE technique is a simple, reproducible and involves fast planning for cardiac sparing, which is ideal for under-resourced departments with heavy workload.

  6. Abubakar A, Shaukat SI, Karim NKA, Kassim MZ, Lim SY, Appalanaido GK, et al.
    Phys Eng Sci Med, 2023 Mar;46(1):339-352.
    PMID: 36847965 DOI: 10.1007/s13246-023-01227-6
    Deep inspiration breath-hold radiotherapy (DIBH-RT) reduces cardiac dose by over 50%. However, poor breath-hold reproducibility could result in target miss which compromises the treatment success. This study aimed to benchmark the accuracy of a Time-of-Flight (ToF) imaging system for monitoring breath-hold during DIBH-RT. The accuracy of an Argos P330 3D ToF camera (Bluetechnix, Austria) was evaluated for patient setup verification and intra-fraction monitoring among 13 DIBH-RT left breast cancer patients. The ToF imaging was performed simultaneously with in-room cone beam computed tomography (CBCT) and electronic portal imaging device (EPID) imaging systems during patient setup and treatment delivery, respectively. Patient surface depths (PSD) during setup were extracted from the ToF and the CBCT images during free breathing and DIBH using MATLAB (MathWorks, Natick, MA) and the chest surface displacement were compared. The mean difference ± standard deviation, correlation coefficient, and limit of agreement between the CBCT and ToF were 2.88 ± 5.89 mm, 0.92, and - 7.36, 1.60 mm, respectively. The breath-hold stability and reproducibility were estimated using the central lung depth extracted from the EPID images during treatment and compared with the PSD from the ToF. The average correlation between ToF and EPID was - 0.84. The average intra-field reproducibility for all the fields was within 2.70 mm. The average intra-fraction reproducibility and stability were 3.74 mm, and 0.80 mm, respectively. The study demonstrated the feasibility of using ToF camera for monitoring breath-hold during DIBH-RT and shows good breath-hold reproducibility and stability during the treatment delivery.
  7. Hizam NDA, Ung NM, Jong WL, Zin HM, Rahman ATA, Loh JPY, et al.
    Phys Med, 2019 Nov;67:34-39.
    PMID: 31655398 DOI: 10.1016/j.ejmp.2019.10.023
    PURPOSE: Intensity Modulated Radiotherapy (IMRT) has changed the practice of radiotherapy since its implementation in the 1990s. The purpose of this study is to review current practice of IMRT in Malaysia.

    METHODS: A survey on medical physics aspects of IMRT is conducted on radiotherapy departments across Malaysia to assess the usage, experience and QA in IMRT, which is done for the first time in this country. A set of questionnaires was designed and sent to the physicist in charge for their responses. The questionnaire consisted of four sections; (i) Experience and qualification of medical physicists, (ii) CT simulation techniques (iii) Treatment planning and treatment unit, (iv) IMRT process, delivery and QA procedure.

    RESULTS: A total of 26 responses were collected, representing 26 departments out of 33 radiotherapy departments in operation across Malaysia (79% response rate). Results showed that the medical physics aspects of IMRT practice in Malaysia are homogenous, with some variations in certain areas of practices. Thirteen centres (52%) performed measurement-based QA using 2D array detector and analysed using gamma index criteria of 3%, 3 mm with variation confidence range. In relation to the IMRT delivery, 44% of Malaysia's physicist takes more than 8 h to plan a head and neck case compared to the UK study possibly due to the lack of professional training.

    CONCLUSIONS: This survey provides a picture of medical physics aspects of IMRT in Malaysia where the results/data can be used by radiotherapy departments to benchmark their local policies and practice.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links