METHODS: Twenty patients with two adjacent missing posterior teeth were recruited. Patients were assigned equally and randomly into two groups; Bicon(®) (6 or 8 mm) and Ankylos(®) (8 mm) implants. A two-stage surgical approach and single crowns were used for implant placement and loading. Outcomes included peri-implant clinical parameters, implant stability (Periotest values; PTVs) and peri-implant bone changes, which were assessed at baseline, 2, 6 and 12 months post-loading.
RESULTS: No implant loss was encountered up to 12 months post-loading. No significant difference in the clinical or radiographic parameters was observed except for PTVs (p < 0.05) that was lower in Ankylos(®) implants.
CONCLUSIONS: The use of short dental implants was associated with excellent 12 months clinical and radiographic outcomes. Ankylos(®) and Bicon(®) implants demonstrated similar peri-implant soft tissue and alveolar bone changes. However, Ankylos(®) implants demonstrated better implant stability at all evaluation intervals.
METHODS: Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05.
RESULTS: The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05).
CONCLUSIONS: The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions.
MATERIAL AND METHODS: Thirty-four patients (mean age 60.70 ± 8.7 years) received telescopic crown or locator attachments for ISOD and completed OHIP-14 (Malaysian version) and DS questionnaires, at baseline (T0 ) with new conventional complete dentures (CCD) and 3 months (T1 ) and 3 years (T2 ) after ISOD conversion. Mandibular bone volume was calculated from cone beam computed tomography (CBCT) datasets using Mimics software. Mean changes (MC) in OHIP-14 and DS at intervals were analyzed using the Wilcoxon signed-rank test and effect size (ES). The association of bone volume, implant attachment type, and other patient variables with the change in OHIP-14 and DS were determined using multivariate linear regression analysis.
RESULTS: The MC in OHIP-14 and DS scores from T0 to T1 and T2 showed significant improvement with moderate and large ES, respectively. Regression analyses for the change in OHIP-14 score from T0 to T2 showed significant association with implant attachment type (P = 0.043), bone volume (P = 0.004), and baseline OHIP-14 (P = 0.001), while for DS, the association was only significant with baseline DS score (P = 0.001).
CONCLUSION: Improvement in patients' OHRQoL and satisfaction with ISOD was associated with their baseline ratings. Mandibular bone volume had a stronger association for improvement in OHRQoL compared to type of attachment.