Displaying all 2 publications

Abstract:
Sort:
  1. Müller AM, Chen B, Wang NX, Whitton C, Direito A, Petrunoff N, et al.
    Obes Rev, 2020 04;21(4):e12976.
    PMID: 31919972 DOI: 10.1111/obr.12976
    The objective of this study is to systematically review the evidence on correlates of sedentary behaviour (SB) among Asian adults. We searched for studies that examined individual, environmental, and political/cultural correlates of total and domain-specific SB (transport, occupation, leisure, and screen time) in Asian adults published from 2000 onwards in nine scientific databases. Two reviewers independently screened identified references. Following quality assessment of included studies, we performed narrative synthesis that considered differences based on SB measurements, regions, and population characteristics (PROSPERO: CRD42018095268). We identified 13 249 papers of which we included 49, from four regions and 12 countries. Researchers conducted cross-sectional analyses and most relied on SB self-report for SB measurement. Of the 118 correlates studied, the following associations were consistent: higher age, living in an urban area (East Asia), and lower mental health with higher total SB; higher education with higher total and occupational SB; higher income with higher leisure-time SB; higher transit density with higher total SB in older East Asians; and being an unmarried women with higher SB in the Middle East. We encourage more research in non-high-income countries across regions, further exploration of important but neglected correlates using longitudinal designs and qualitative research, and the use of objective instruments to collect SB data.
  2. Müller AM, Wang NX, Yao J, Tan CS, Low ICC, Lim N, et al.
    JMIR Mhealth Uhealth, 2019 10 02;7(10):e14120.
    PMID: 31579026 DOI: 10.2196/14120
    BACKGROUND: Wrist-worn activity trackers are popular, and an increasing number of these devices are equipped with heart rate (HR) measurement capabilities. However, the validity of HR data obtained from such trackers has not been thoroughly assessed outside the laboratory setting.

    OBJECTIVE: This study aimed to investigate the validity of HR measures of a high-cost consumer-based tracker (Polar A370) and a low-cost tracker (Tempo HR) in the laboratory and free-living settings.

    METHODS: Participants underwent a laboratory-based cycling protocol while wearing the two trackers and the chest-strapped Polar H10, which acted as criterion. Participants also wore the devices throughout the waking hours of the following day during which they were required to conduct at least one 10-min bout of moderate-to-vigorous physical activity (MVPA) to ensure variability in the HR signal. We extracted 10-second values from all devices and time-matched HR data from the trackers with those from the Polar H10. We calculated intraclass correlation coefficients (ICCs), mean absolute errors, and mean absolute percentage errors (MAPEs) between the criterion and the trackers. We constructed decile plots that compared HR data from Tempo HR and Polar A370 with criterion measures across intensity deciles. We investigated how many HR data points within the MVPA zone (≥64% of maximum HR) were detected by the trackers.

    RESULTS: Of the 57 people screened, 55 joined the study (mean age 30.5 [SD 9.8] years). Tempo HR showed moderate agreement and large errors (laboratory: ICC 0.51 and MAPE 13.00%; free-living: ICC 0.71 and MAPE 10.20%). Polar A370 showed moderate-to-strong agreement and small errors (laboratory: ICC 0.73 and MAPE 6.40%; free-living: ICC 0.83 and MAPE 7.10%). Decile plots indicated increasing differences between Tempo HR and the criterion as HRs increased. Such trend was less pronounced when considering the Polar A370 HR data. Tempo HR identified 62.13% (1872/3013) and 54.27% (5717/10,535) of all MVPA time points in the laboratory phase and free-living phase, respectively. Polar A370 detected 81.09% (2273/2803) and 83.55% (9323/11,158) of all MVPA time points in the laboratory phase and free-living phase, respectively.

    CONCLUSIONS: HR data from the examined wrist-worn trackers were reasonably accurate in both the settings, with the Polar A370 showing stronger agreement with the Polar H10 and smaller errors. Inaccuracies increased with increasing HRs; this was pronounced for Tempo HR.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links