Toggle navigation
MyMedR
Browse
Help
Login
Advanced
Displaying
1
publication
Export
Selected (RIS file)
Selected (Vancouver citation text file)
Abstract:
show
hide
Sort:
Relevance
Relevance
Recent
Title
Journal
First author
Last author
Multifocus watermarking approach based on discrete cosine transform
Waheed SR
, Alkawaz MH, Rehman A, Almazyad AS, Saba T
Microsc Res Tech
, 2016 May;79(5):431-7.
PMID: 26918523
DOI:
10.1002/jemt.22646
Abstract
Image fusion process consolidates data and information from various images of same sight into a solitary image. Each of the source images might speak to a fractional perspective of the scene, and contains both "pertinent" and "immaterial" information. In this study, a new image fusion method is proposed utilizing the Discrete Cosine Transform (DCT) to join the source image into a solitary minimized image containing more exact depiction of the sight than any of the individual source images. In addition, the fused image comes out with most ideal quality image without bending appearance or loss of data. DCT algorithm is considered efficient in image fusion. The proposed scheme is performed in five steps: (1) RGB colour image (input image) is split into three channels R, G, and B for source images. (2) DCT algorithm is applied to each channel (R, G, and B). (3) The variance values are computed for the corresponding 8 × 8 blocks of each channel. (4) Each block of R of source images is compared with each other based on the variance value and then the block with maximum variance value is selected to be the block in the new image. This process is repeated for all channels of source images. (5) Inverse discrete cosine transform is applied on each fused channel to convert coefficient values to pixel values, and then combined all the channels to generate the fused image. The proposed technique can potentially solve the problem of unwanted side effects such as blurring or blocking artifacts by reducing the quality of the subsequent image in image fusion process. The proposed approach is evaluated using three measurement units: the average of Q(abf) , standard deviation, and peak Signal Noise Rate. The experimental results of this proposed technique have shown good results as compared with older techniques. Microsc. Res. Tech. 79:431-437, 2016. © 2016 Wiley Periodicals, Inc.
Related Terms
Try searching for something
Search History
Clear
Filters
Free full-text
PubMed
PubMed-only
MyJurnal
MyJurnal-only
Malaysian-only
Filter
Contact Us
Please provide feedback to Administrator (
[email protected]
)
External Links
PubMed
MeSH browser
MyJurnal