METHODS: This was a cross-sectional study on medical students from the University of Malaya. Diagnosis of NAFLD was by transabdominal ultrasonography and following exclusion of significant alcohol intake and other causes of chronic liver disease.
RESULTS: Data of 469 subjects were analyzed (mean age 23.2 ± 2.4 years, 40.3 % male). The racial distribution was: Chinese 53.9 %, Malay 30.5 % and Indian 15.6 %. The overall prevalence of NAFLD was 7.9 %. Subjects with NAFLD were older, had greater BMI and WC, higher SBP and DBP, higher FBS, serum TG and LDL levels, and lower serum HDL level. The prevalence of NAFLD was higher among males compared to females (17.9 % vs. 3.3 %, p
METHODS: Consecutive NAFLD patients who underwent liver biopsy were enrolled in this study and had two sets each of pSWE and TE examinations by a nurse and a doctor on the same day of liver biopsy procedure. The medians of the four sets of pSWE and TE were used for evaluation of diagnostic accuracy using area under receiver operating characteristic curve (AUROC). Intra-observer and inter-observer variability was analyzed using intraclass correlation coefficients.
RESULTS: Data for 100 NAFLD patients (mean age 57.1 ± 10.2 years; male 46.0%) were analyzed. The AUROC of TE for diagnosis of fibrosis stage ≥ F1, ≥ F2, ≥ F3, and F4 was 0.89, 0.83, 0.83, and 0.89, respectively. The corresponding AUROC of pSWE was 0.80, 0.72, 0.69, and 0.79, respectively. TE was significantly better than pSWE for the diagnosis of fibrosis stages ≥ F2 and ≥ F3. The intra-observer and inter-observer variability of TE and pSWE measurements by the nurse and doctor was excellent with intraclass correlation coefficient > 0.96.
CONCLUSION: Transient elastography was significantly better than pSWE for the diagnosis of fibrosis stage ≥ F2 and ≥ F3. Both TE and pSWE had excellent intra-observer and inter-observer variability when performed by healthcare personnel of different backgrounds.
METHODS: A Total of 51 patients with 105 carotid artery plaques were screened using 3D and 2D US probes attached to the same US scanner. Two independent observers characterized the plaques based on the morphological features namely echotexture, echogenicity and surface characteristics. The scores assigned to each morphological feature were used to determine intra- and inter-observer performance. The level of agreement was measured using Kappa coefficient.
RESULTS: The first observer with 2D US showed fair (k=0.4-0.59) and very strong (k>0.8) with 3D US intra-observer agreements using three morphological features. The second observer indicated moderate strong (k=0.6-0.79) with 2D US and very strong with 3D US (k>0.8) intra-observer performances. Moderate strong (k=0.6-0.79) and very strong (k>0.8) inter-observer agreements were reported with 2D US and 3D US respectively. The results with 2D and 3D US were correlated 62% using only echotexture and 56% using surface morphology coupled with echogenicity. 3D US gave a lower score than 2D 71% of the time (p=0.005) in disagreement cases.
CONCLUSION: High reproducibility in carotid plaque characterization was obtained using 3D US rather than 2D US. Hence, it can be a preferred imaging modality in routine or follow up plaque screening of patients with carotid artery disease.
METHODS: The study comprised 106 chronic kidney disease (CKD) patients and 203 control subjects. Conventional ultrasound was performed to measure the kidney length and cortical thickness. SWE imaging was performed to measure renal parenchymal stiffness. Diagnostic performance of SWE and conventional ultrasound were correlated with serum creatinine, urea levels and eGFR.
RESULTS: Pearson's correlation coefficient revealed a negative correlation between YM measurements and eGFR (r = -0.576, p < 0.0001). Positive correlations between YM measurements and age (r = 0.321, p < 0.05), serum creatinine (r = 0.375, p < 0.0001) and urea (r = 0.287, p < 0.0001) were also observed. The area under the receiver operating characteristic curve for SWE (0.87) was superior to conventional ultrasound alone (0.35-0.37). The cut-off value of less or equal to 4.31 kPa suggested a non-diseased kidney (80.3% sensitivity, 79.5% specificity).
CONCLUSION: SWE was superior to renal length and cortical thickness in detecting CKD. A value of 4.31 kPa or less showed good accuracy in determining whether a kidney was diseased or not. Advances in knowledge: On SWE, CKD patients show greater renal parenchymal stiffness than non-CKD patients. Determining a cut-off value between normal and diseased renal parenchyma may help in early non-invasive detection and management of CKD.
METHODS: 85 participants (43 fallers, 42 non-fallers) were evaluated with conventional MRI and diffusion tensor imaging (DTI) sequences of the brain. DTI metrics were obtained from selected WMT using tract-based spatial statistics (TBSS) method. This was followed by binary logistic regression to investigate the clinical variables that could act as confounding elements on the outcomes. The TBSS analysis was then repeated, but this time including all significant predictor variables from the regression analysis as TBSS covariates.
RESULTS: The mean diffusivity (MD) and axial diffusivity (AD) and to a lesser extent radial diffusivity (RD) values of the projection fibers and commissural bundles were significantly different in fallers (p < 0.05) compared to non-fallers. However, the final logistic regression model obtained showed that only functional reach, white matter lesion volume, hypertension and orthostatic hypotension demonstrated statistical significant differences between fallers and non-fallers. No significant differences were found in the DTI metrics when taking into account age and the four variables as covariates in the repeated analysis.
CONCLUSION: This DTI study of 85 subjects, do not support DTI metrics as a singular factor that contributes independently to the fall outcomes. Other clinical and imaging factors have to be taken into account.
MATERIALS AND METHODS: Breast lesions and axillae of 107 patients were assessed using B-mode ultrasound and SWE. Histopathology was the diagnostic gold standard.
RESULTS: In metastatic axillary lymph nodes, qualitative SWE using color patterns had the highest area under curve (AUC) value, followed by B-mode Ultrasound (cortical thickening >3 mm) and quantitative SWE using Emax of 15.2 kPa (AUC of 81.3%, 70.1%, and 61.2%, respectively). Qualitative SWE exhibited better diagnostic performance than the other two parameters, with sensitivity of 96.0% and specificity of 56.1%. Combination of B-mode Ultrasound (using cortical thickness of >3 mm as cut-off point) and qualitative SWE (Color patterns of 2 to 4) showed sensitivity of 71.6%, specificity of 95%, PPV of 96%, NPV of 66.7%, and accuracy of 80.4%.
CONCLUSION: Qualitative SWE assessment exhibited higher accuracy compared to quantitative values. Qualitative SWE as an adjunct to B-mode ultrasound can further improve the diagnostic accuracy of metastatic ALN in breast cancer.
METHODS: The review was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Literature search was conducted in Pubmed, Web of Science and Scopus database up to 23 October 2021. To evaluate risk and bias applicability, the Cochrane risk-of bias tool and GRADE was used. The review was registered under PROSPERO CRD42021265303.
RESULTS: A total of 2921 articles were identified. 104 full texts were examined and 26 studies included in systematic review. 11 studies performed on native kidneys and 15 studies on transplanted kidney. A wide range of impact factors was found that affect the accuracy of SWE of renal fibrosis in adult patients.
CONCLUSIONS: Compared to point SWE, two-dimensional SWE with elastogram could enable better selection of the region of interest in kidneys, leading to reproducible results. Tracking waves were attenuated as the depth from skin to region of interest increased, therefore, SWE is not recommended for overweight or obese patients. Variable transducer forces might also affect SWE reproducibility, thus, training of operators to ensure consistent operator-dependent transducer forces may be helpful.
ADVANCES IN KNOWLEDGE: This review provides a holistic insight on the efficiency of using SWE in evaluating pathological changes in native and transplanted kidneys, thereby contributing to the knowledge of its utilisation in clinical practice.
METHODS: Data for this study were obtained from final year medical students' exit examination (n=185). Retrospective analysis of data was conducted using SPSS. Means for the six CSs assessed across the 16 stations were computed and compared.
RESULTS: Means for history taking, physical examination, communication skills, clinical reasoning skills (CRSs), procedural skills (PSs), and professionalism were 6.25±1.29, 6.39±1.36, 6.34±0.98, 5.86±0.99, 6.59±1.08, and 6.28±1.02, respectively. Repeated measures ANOVA showed there was a significant difference in the means of the six CSs assessed [F(2.980, 548.332)=20.253, p<0.001]. Pairwise multiple comparisons revealed significant differences between the means of the eight pairs of CSs assessed, at p<0.05.
CONCLUSIONS: CRSs appeared to be the weakest while PSs were the strongest, among the six CSs assessed. Students' unsatisfactory performance in CRS needs to be addressed as CRS is one of the core competencies in medical education and a critical skill to be acquired by medical students before entering the workplace. Despite its challenges, students must learn the skills of clinical reasoning, while clinical teachers should facilitate the clinical reasoning process and guide students' clinical reasoning development.