Displaying all 4 publications

Abstract:
Sort:
  1. Crum EM, Che Muhamed AM, Barnes M, Stannard SR
    PMID: 28572749 DOI: 10.1186/s12970-017-0172-0
    BACKGROUND: Recent research has indicated that pomegranate extract (POMx) may improve performance during aerobic exercise by enhancing the matching of vascular oxygen (O2) provision to muscular requirements. POMx is rich in ellagitannin polyphenols and nitrates (NO3-), which are both associated with improvements in blood flow and O2 delivery. Primarily, this study aimed to determine whether POMx improves performance in a cycling time trial to exhaustion at 100%VO2max (TTE100%) in highly-trained cyclists. In addition, we investigated if the O2 cost (VO2) of submaximal exercise was lower with POMx, and whether any changes were greater at high altitude where O2 delivery is impaired.

    METHODS: Eight cyclists exercised at three submaximal intensities before completing a TTE100% at sea-level (SEA) and at 1657 m of altitude (ALT), with pre-exercise consumption of 1000 mg of POMx or a placebo (PLAC) in a randomized, double-blind, crossover design. Data were analysed using a three way (treatment x altitude x intensity) or two-way (treatment x altitude) repeated measures ANOVA with a Fisher's LSD post-hoc analysis. Significance was set at p ≤ 0.05. The effect size of significant interactions was calculated using Cohen's d.

    RESULTS: TTE100% performance was reduced in ALT but was not influenced by POMx (p > 0.05). Plasma NO3- were 10.3 μmol greater with POMx vs. PLAC (95% CI, 0.8, 19.7,F1,7 = 7.83, p  0.05). Submaximal VO2 values were not affected by POMx (p ≥ 0.05).

    CONCLUSIONS: The restoration of SEA VO2 values at ALT is likely driven by the high polyphenol content of POMx, which is proposed to improve nitric oxide bioavailability. Despite an increase in VO2, no change in exercise performance occurred and therefore this study does not support the use of POMx as an ergogenic supplement.

  2. Che Muhamed AM, Atkins K, Stannard SR, Mündel T, Thompson MW
    Temperature (Austin), 2016;3(3):455-464.
    PMID: 28349085 DOI: 10.1080/23328940.2016.1182669
    This study examined the thermoregulatory and circulatory responses, and exercise performance of trained distance runners during exercise in the heat (31°C) at varying relative humidity (RH). In a randomized order, 11 trained male distance runners performed 5 60 min steady-state runs at a speed eliciting 70% of VO2max in RH of 23, 43, 52, 61 and 71%. This was followed immediately with an incremental exercise test to volitional exhaustion. Core (Tre) and mean skin temperature (T¯sk), cardiac output (Q), heart rate (HR), and stroke volume (SV) were recorded at regular intervals. A significant (P = 0.003) main effect was detected for RH on mean body temperature (Tb), with a significantly higher Tb detected during steady-state exercise in the 61 and 71% RH compared to that in the 23% RH. During the steady-state exercise, no differences were detected in whole body sweat loss (P = 0.183). However, a significant main effect of RH was observed for HR and SV (P = 0.001 and 0.006, respectively) but not Q (P = 0.156). The time to exhaustion of the incremental exercise test was significantly reduced at 61 and 71% RH compared with 23% RH (P = 0.045 and 0.005, respectively). Despite an increase in dry heat loss, a greater thermoregulatory and circulatory stress was evident during steady-state exercise at 61 and 71% RH. This ultimately limits the capacity to perform the subsequent incremental exercise to exhaustion. This study highlighted that in a warm environment, the range of the prescriptive zone progressively narrows as RH increases.
  3. Che Muhamed AM, Yusof HA, Stannard SR, Mündel T, Thompson MW
    Front Physiol, 2019;10:507.
    PMID: 31133869 DOI: 10.3389/fphys.2019.00507
    The understanding that fluid ingestion attenuates thermoregulatory and circulatory stress during exercise in the heat was based on studies conducted in relatively dry (∼50% RH) environments. It remains undetermined whether similar effects occur during exercise in a warm and more humid environment, where evaporative capacity is reduced. Nine well-trained, unacclimatised male runners were randomly assigned to perform four experimental trials where they ran for 60 min at an intensity of 70% VO2max followed by an incremental exercise test until volitional exhaustion. The four trials consisted of non-fluid ingestion (NF) and fluid ingestion (FI) in a warm-dry (WD) and warm-humid condition (WH). Time to exhaustion (TTE), body temperature (Tb), whole body sweat rate, partitional calorimetry measures, heart rate and plasma volume were recorded during exercise. There was no significant difference in Tb following 60 min of exercise in FI and NF trial within both WD (37.3°C ± 0.4 vs. 37.4°C ± 0.3; p > 0.05) and WH conditions (38.0°C ± 0.4 vs. 38.1°C ± 0.4; p > 0.05). The TTE was similar between FI and NF trials in both WH and WD, whereas exercise capacity was significantly shorter in WH than WD (9.1 ± 2.8 min vs. 12.7 ± 2.4 min, respectively; p = 0.01). Fluid ingestion failed to provide any ergogenic benefit in attenuating thermoregulatory and circulatory stress during exercise in the WH and WD conditions. Consequently, exercise performance was not enhanced with fluid ingestion in the warm-humid condition, although the humid environment detrimentally affected exercise endurance.
  4. Lei TH, Schlader ZJ, Che Muhamed AM, Zheng H, Stannard SR, Kondo N, et al.
    Eur J Appl Physiol, 2020 Apr;120(4):841-852.
    PMID: 32072226 DOI: 10.1007/s00421-020-04322-8
    PURPOSE: Recent studies have determined that ambient humidity plays a more important role in aerobic performance than dry-bulb temperature does in warm environments; however, no studies have kept humidity constant and independently manipulated temperature. Therefore, the purpose of this study was to determine the contribution of dry-bulb temperature, when vapor pressure was matched, on the thermoregulatory, perceptual and performance responses to a 30-min cycling work trial.

    METHODS: Fourteen trained male cyclists (age: 32 ± 12 year; height: 178 ± 6 cm; mass: 76 ± 9 kg; [Formula: see text]: 59 ± 9 mL kg-1 min-1; body surface area: 1.93 ± 0.12 m2; peak power output: 393 ± 53 W) volunteered, and underwent 1 exercise bout in moderate heat (MOD: 34.9 ± 0.2 °C, 50.1 ± 1.1% relative humidity) and 1 in mild heat (MILD: 29.2 ± 0.2 °C, 69.4 ± 0.9% relative humidity) matched for vapor pressure (2.8 ± 0.1 kPa), with trials counterbalanced.

    RESULTS: Despite a higher weighted mean skin temperature during MOD (36.3 ± 0.5 vs. 34.5 ± 0.6 °C, p 

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links