Displaying all 3 publications

Abstract:
Sort:
  1. Lee J, Kim YE, Kim HY, Sinniah M, Chong CK, Song HO
    Sci Rep, 2015;5:18077.
    PMID: 26655854 DOI: 10.1038/srep18077
    High levels of anti-dengue IgM or IgG can be detected using numerous rapid diagnostic tests (RDTs). However, the sensitivity and specificity of these tests are reduced by changes in envelope glycoprotein antigenicity that inevitably occur in limited expression systems. A novel RDT was designed to enhance diagnostic sensitivity. Dengue viruses cultured in animal cells were used as antigens to retain the native viral coat protein. Monoclonal antibodies (mAbs) were then developed, for the first time, against domain I of envelope glycoprotein (EDI). The anti-dengue EDI mAb was employed as a capturer, and EDII and EDIII, which are mainly involved in the induction of neutralizing antibodies in patients, were fully available to bind to anti-dengue IgM or IgG in patients. A one-way automatic blood separation device prevented reverse migration of plasma and maximize the capture of anti-dengue antibodies at the test lines. A clinical evaluation in the field proved that the novel RDT (sensitivities of 96.5% and 96.7% for anti-dengue IgM and IgG) is more effective in detecting anti-dengue antibodies than two major commercial tests (sensitivities of 54.8% and 82% for SD BIOLINE; 50.4% and 75.3% for PanBio). The innovative format of RDT can be applied to other infectious viral diseases.
  2. Kim JH, Chong CK, Sinniah M, Sinnadurai J, Song HO, Park H
    J Clin Virol, 2015 Apr;65:11-9.
    PMID: 25766980 DOI: 10.1016/j.jcv.2015.01.018
    BACKGROUND: Dengue is a mosquito-borne disease that causes a public health problem in tropical and subtropical countries. Current immunological diagnostics based on IgM and/or nonstructural protein 1 (NS1) antigen are limited for acute dengue infection due to low sensitivity and accuracy.
    OBJECTIVES: This study aimed to develop a one-step multiplex real-time RT-PCR assay showing higher sensitivity and accuracy than previous approaches.
    STUDY DESIGN: Serotype-specific primers and probes were designed through the multiple alignment of NS1 gene. The linearity and limit of detection (LOD) of the assay were determined. The assay was clinically validated with an evaluation panel that was immunologically tested by WHO and Malaysian specimens.
    RESULTS: The LOD of the assay was 3.0 log10 RNA copies for DENV-1, 2.0 for DENV-3, and 1.0 for DENV-2 and DENV-4. The assay showed 95.2% sensitivity (20/21) in an evaluation panel, whereas NS1 antigen- and anti-dengue IgM-based immunological assays exhibited 0% and 23.8-47.6% sensitivities, respectively. The assay showed 100% sensitivity both in NS1 antigen- and anti-dengue IgM-positive Malaysian specimens (26/26). The assay provided the information of viral loads and serotype with discrimination of heterotypic mixed infection.
    CONCLUSIONS: The assay could be clinically applied to early dengue diagnosis, especially during the first 5 days of illness and approximately 14 days after infection showing an anti-dengue IgM-positive response.
  3. Cho SJ, Lee J, Lee HJ, Jo HY, Sinniah M, Kim HY, et al.
    Int J Biol Sci, 2016;12(7):824-35.
    PMID: 27313496 DOI: 10.7150/ijbs.14408
    Rapid diagnostic tests (RDTs) can detect anti-malaria antibodies in human blood. As they can detect parasite infection at the low parasite density, they are useful in endemic areas where light infection and/or re-infection of parasites are common. Thus, malaria antibody tests can be used for screening bloods in blood banks to prevent transfusion-transmitted malaria (TTM), an emerging problem in malaria endemic areas. However, only a few malaria antibody tests are available in the microwell-based assay format and these are not suitable for field application. A novel malaria antibody (Ab)-based RDT using a differential diagnostic marker for falciparum and vivax malaria was developed as a suitable high-throughput assay that is sensitive and practical for blood screening. The marker, merozoite surface protein 1 (MSP1) was discovered by generation of a Plasmodium-specific network and the hierarchical organization of modularity in the network. Clinical evaluation revealed that the novel Malaria Pf/Pv Ab RDT shows improved sensitivity (98%) and specificity (99.7%) compared with the performance of a commercial kit, SD BioLine Malaria P.f/P.v (95.1% sensitivity and 99.1% specificity). The novel Malaria Pf/Pv Ab RDT has potential for use as a cost-effective blood-screening tool for malaria and in turn, reduces TTM risk in endemic areas.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links