  1. Shariffuddin II, Wang CY
    Anaesthesia, 2008 Jan;63(1):82-5.
    PMID: 18086075
    We compared the performance of the Ambu AuraOnce Laryngeal Mask with that of the LMA Classic laryngeal mask airway during controlled anaesthesia. Forty patients requiring intermittent positive pressure ventilation were studied using a randomised crossover design. The mean (SD) oropharyngeal leak pressure for the Ambu device (19 (7.5) cmH2O) was significantly greater than for the LMA Classic (15 (5.2) cmH2O; p = 0.004), and the number of attempts for successful insertions was significantly less (39 (50%) vs 45 (56%), respectively; p = 0.02). There was one failure to obtain a patent airway with the Ambu Laryngeal Mask and none with the LMA Classic. Insertion of the Ambu Laryngeal Mask required more manipulations to achieve a patent airway than did the LMA Classic (6 (15%) vs 1 (2.5%), respectively; p = 0.045), but the time taken for insertion was similar between the two groups. The incidence of trauma, grade of fibreoptic view, peak airway pressure and quality of ventilation during maintenance of anaesthesia were similar in both groups.
  2. Shariffuddin II, Rai V, Chan YK, Muniandy RK
    BMJ Case Rep, 2014;2014.
    PMID: 24862427 DOI: 10.1136/bcr-2014-205135
    Care of an acutely ill parturient is particularly difficult when we have to balance the needs of both mother and the fetus to survive. The literature suggests there should be emphasis on stabilising the mother's condition. In dealing with metabolic acidosis, however, we believe delivering the baby early might not only relieve the threat of the acidosis on the mother, it may be the only way to deliver a live baby. We report two parturient women with severe metabolic acidosis which was considerably reduced very soon after the delivery and how our timely delivery resulted in the birth of two neurologically intact babies.
  3. Tham LY, Beh ZY, Shariffuddin II, Wang CY
    Korean J Anesthesiol, 2019 12;72(6):606-609.
    PMID: 31304693 DOI: 10.4097/kja.d.18.00354
    BACKGROUND: The laryngeal mask airway (LMAⓇ) ProtectorTM (Teleflex Medical Co., Ireland) is the latest innovation in the second generation of LMA devices. One distinguishing feature of this device is its integrated, color-coded cuff pressure indicator (Cuff PilotTM technology) which enables continuous cuff pressure monitoring and allows adjustments when necessary; this ensures patient safety due to better monitoring.

    CASE: We report a case of postoperative unilateral hypoglossal nerve palsy after uncomplicated use of the LMA Protector. To the best of our knowledge, this could be the second reported case.

    CONCLUSIONS: This case demonstrates that anesthetists need to routinely measure cuff pressure and that the Cuff PilotTM technology is not a panacea for potential cranial nerve injury after airway manipulation.

  4. Loh PS, Shariffuddin II, Chaw SH, Mansor M
    Med J Malaysia, 2021 01;76(1):98-100.
    PMID: 33510117
    Around June 2020, many institutions restarted full operating schedules to clear the backlog of postponed surgeries because of the first wave in the COVID-19 pandemic. In an online survey distributed among anaesthestists in Asian countries at that time, most of them described their safety concerns and recommendations related to the supply of personal protective equipment and its usage. The second concern was related to pre-operative screening for all elective surgical cases and its related issues. The new norm in practice was found to be non-standardized and involved untested devices or workflow that have since been phased out with growing evidence. Subsequent months after reinstating full elective surgeries tested the ability of many hospitals in handling the workload of non-COVID surgical cases together with rising COVID-19 positive cases in the second and third waves when stay-at-home orders eased.
  5. Shariffuddin II, Teoh WH, Wahab S, Wang CY
    BMC Anesthesiol, 2018 01 05;18(1):3.
    PMID: 29304735 DOI: 10.1186/s12871-017-0464-6
    BACKGROUND: Ambulatory surgery has recently gain popularity, as it is a good method of optimizinghospital resources utilization. To support ambulatory surgery, anaesthetic goals nowrevolve around patients' early recovery with minimal pain and nausea, expedientdischarge home and prompt resumption of activities of daily living. In this study, weevaluated the effect of a single pre-induction dose of dexmedetomidine on anaestheticrequirements, postoperative pain and clinical recovery after ambulatory ureteroscopy andureteric stenting under general anaesthesia.

    METHODS: Sixty patients were randomised to receive IV dexmedetomidine 0.5 μg.kg-1 (Group DEX, n = 30) or IV saline (Group P, n = 30). General anaesthesia was maintained with Sevoflurane: oxygen: air, titrated to BIS 40-60. Pain intensity, sedation, rescue analgesics, nausea/vomiting and resumption of daily activities were recorded at 1 h, and postoperative day (POD) 1-5.

    RESULTS: Group DEX patients had significant reduction in sevoflurane minimum alveolar concentration (MAC), mean (SD) DEX vs. Placebo 0.6 (0.2) vs. 0.9 (0.1), p = 0.037; reduced postoperative resting pain at 1 h (VAS 0-10) (mean (SD) 1.00 (1.84) vs. 2.63 (2.78), p = 0.004), POD 1 (mean (SD) 1.50 (1.48) vs. 2.87 (2.72), p = 0.002), POD 2 (0.53 (0.97) vs. 1.73 (1.96), p = 0.001) and POD 3 (0.30 (0.75) vs. 0.89 (1.49), p = 0.001). DEX patients also had less pain on movement POD 1 (3.00 (2.12) vs. 4.30 (3.10), p = 0.043) and POD 2 (2.10 (1.98) vs. 3.10 (2.46), p = 0.040), with higher resumption of daily activities by 48 h compared to placebo, 87% vs. 63%, p = 0.04.

    CONCLUSIONS: We conclude that a single dose of dexmedetomidine was a useful adjuvant in reducing MAC and postoperative pain (at 1 h and POD 1-3), facilitating faster return to daily activities by 48 h.

    TRIAL REGISTRATION: The Australian New Zealand Clinical Trials Registry (ANZCTR), ACTRN12617001120369 , 31st July 2017, retrospectively registered.

  6. Shariffuddin II, Teoh WH, Tang E, Hashim N, Loh PS
    Anaesth Intensive Care, 2017 03;45(2):244-250.
    PMID: 28267947 DOI: 10.1177/0310057X1704500215
    Newer second generation supraglottic airway devices may perform differently in vivo due to material and design modifications. We compared performance characteristics of the Ambu® AuraGain™ and LMA Supreme™ Second Seal™ in 100 spontaneously breathing anaesthetised patients in this randomised controlled study. We studied oropharyngeal leak pressures (OLP) (primary outcome) and secondarily, ease of insertion, success rates, haemodynamic response, time to insertion, and complications of usage. We found no significant difference in OLP between the AuraGain versus the LMA Supreme, mean (standard deviation, SD) 24.1 (7.4) versus 23.6 (6.2) cmH2O, P=0.720. First-attempt placement rates of the AuraGain were comparable to the LMA Supreme, 43/50 (86%) versus 39/50 (78%), P=0.906, with an overall 98% insertion success rate for the AuraGain and 88% for the LMA Supreme after three attempts, P=0.112. However, the AuraGain was deemed subjectively harder to insert, with only 24/50 (48%) versus 37/50 (74%) of AuraGain insertions being scored 1 = easy (on a 5 point scale), P=0.013, and also took longer to insert, 33.4 (SD 10.9) versus 27.3 (SD 11.4) seconds, P=0.010. The AuraGain needed a smaller volume of air (16.4 [SD 6.8] versus 23.0 [SD 7.4] ml, P <0.001) to attain intracuff pressures of 60 cmH2O, facilitated more successful gastric tube insertion (100% versus 90.9%, P=0.046), and had significantly decreased sore throat incidence (10% versus 38%, P=0.020). One AuraGain and six LMA Supremes failed to be placed within the stipulated 120 seconds trial definition of 'success'; these patients had risk factors for failed supraglottic insertion. In conclusion, both devices had similar OLPs and performed satisfactorily. However, the AuraGain resulted in less postoperative sore throat despite being harder to and taking longer to, insert.
  7. Lee ZX, Ng KT, Ang E, Wang CY, Binti Shariffuddin II
    Int J Surg, 2020 Oct;82:192-199.
    PMID: 32871271 DOI: 10.1016/j.ijsu.2020.08.034
    BACKGROUND: Studies have reported that general anesthesia (GA), especially volatile agents were associated with higher cancer recurrence rate after cancer resection surgery. However, the effect of supplementary regional anesthesia (RA) in reducing the use of anesthetic agents on oncological outcomes remains unclear. The primary aim of this meta-analysis was to examine the effect of adjunctive use of RA on the cancer recurrence rate in adults undergoing cancer resection surgery.

    METHODS: MEDLINE, EMBASE and CENTRAL were systematically searched for randomized control trials (RCTs) from its inception until April 2020.

    RESULTS: Six RCTs (n = 3139 patients) were included. In comparison to the GA alone, our meta-analysis demonstrated no significant difference in the cancer recurrence rate in patients who received the adjunctive use of RA in the routine care of GA (3 studies, n = 2380 patients; odds ratio 0.93, 95%CI 0.63-1.39, ρ = 0.73, certainty of evidence = very low). Our review also showed no significant difference in cancer-related mortality (2 studies, n = 545; odds ratio 1.20, 95%CI 0.83-1.74, ρ = 0.33, certainty of evidence = low), all-cause mortality (3 studies, n = 2653; odds ratio 0.98, 95%CI 0.69-1.39, ρ = 0.89, certainty of evidence = low) and duration of cancer-free survival (2 studies, n = 659; mean difference 0.00 years, 95%CI -0.25-0.25, ρ = 1.00, certainty of evidence = high).

    CONCLUSION: This meta-analysis concluded that the adjunctive use of RA in the routine care of GA did not reduce cancer recurrence rate in cancer resection surgery. However, this finding needs to be interpreted with caution due to low level of evidence, substantial heterogeneity and potential risk of bias across the included studies.

    STUDY REGISTRATION NUMBER: CRD42020171368.

  8. Foo LL, Shariffuddin II, Chaw SH, Lee PK, Lee CE, Chen YS, et al.
    Expert Rev Med Devices, 2018 Aug;15(8):597-603.
    PMID: 30095289 DOI: 10.1080/17434440.2018.1506329
    BACKGROUND: The Baska functional endoscopic sinus surgery (FESS) mask is a new supraglottic airway designed for head and neck procedures. This prospective, randomized controlled trial compared the oropharyngeal leak pressure (OLP) of the Baska FESS mask with the laryngeal mask airway (LMA) Supreme in different head and neck positions.

    METHODS: One hundred patients undergoing elective surgery were recruited. OLP was compared in supine position, 45° lateral rotation, 45° neck extension, and 30° neck flexion. Glottic view, insertion time, ease of insertion, number of attempts, ease and time of insertion of gastric tube, and complications were also compared.

    RESULTS: The OLP of the Baska FESS was higher than the LMA Supreme in all head and neck positions studied (p 

  9. Chaw S, Lo Y, Shariffuddin II, Wong J, Lee J, Leong DW, et al.
    Paediatr Anaesth, 2019 01;29(1):68-76.
    PMID: 30381868 DOI: 10.1111/pan.13528
    BACKGROUND: Effective pain management involves a cycle of continual pain assessment, good pain control strategies, and assessment of a standard quality improvement measures. A validated questionnaire that focuses on the quality of postoperative pain management in pediatric surgical patients and parental satisfaction on pain treatment is lacking. We, therefore, modified the revised American Pain Society Patient Outcome Questionnaire to evaluate the quality of postoperative pain management in a pediatric surgical setting. The primary aim of this study was to validate the modified version of revised American Pain Society Patient Outcome Questionnaire.

    METHODS: Parents whose children aged below 12 years and were scheduled for elective surgery in a teaching hospital, were approached to participate in this survey. The reliability of the modified version of revised American Pain Society Patient Outcome Questionnaire was evaluated using Cronbach's alpha test, while the construct validity was assessed with a principal component analysis using a varimax rotation. The parental satisfaction with pain treatment received was measured.

    RESULTS: A total of 108 parents completed the questionnaire. The internal consistency of the questionnaire shows a Cronbach's alpha of 0.798. Principal component analysis revealed a four-factor structure of the 12 items which explained 69.7% of the total variance. The factors are "Interference of sleep and activity," "Pain severity and drowsiness," "Perception of care," and "Adverse effects," respectively. Our study showed that this questionnaire is a valid and reliable measure for "Interference of sleep and activity" and "Pain severity and drowsiness" factors, but not for "Perception of care" and "Adverse effects." The results for "Perception of care" and "Adverse effects," therefore, should be reported as individual items instead of total score. The parental satisfaction with pain treatment given was good (median 8.0; IQR 3.0).

    CONCLUSION: The modified version of revised American Pain Society Patient Outcome Questionnaire is a feasible and easy instrument to administer. The questionnaire can be used to obtain feedback from parents about the outcomes and experiences of pain management and is helpful in continuous quality evaluation and improvement in the postoperative care in a pediatric setting.

  10. Josephine C, Shariffuddin II, Chaw SH, Ng KWS, Ng KT
    Asian J Anesthesiol, 2021 03 01;59(1):7-21.
    PMID: 33504143 DOI: 10.6859/aja.202103_59(1).0002
    Dexmedetomidine is a highly selective α2-adrenoceptor agonist, which is off-labelled use for pediatric sedation. However, the hemodynamic responses of dexmedetomidine remain unclear in the pediatric population. The primary objectives of this systematic review and meta-analysis were to examine the hemodynamic effects of high-dose and low-dose dexmedetomidine in pediatric patients undergoing surgery. EMBASE, MEDLINE, and CENTRAL were systematically searched from its inception until April 2019. All randomized clinical trials comparing high-dose (> 0.5 mcg/kg) and low-dose (≤ 0.5 mcg/ kg) dexmedetomidine in pediatric surgical patients were included, regardless of the types of surgeries. Observational studies, case series, and case reports were excluded. Four trials (n = 473) were included in this review. Our review demonstrated that high-dose dexmedetomidine was associated with lower heart rate than low-dose dexmedetomidine after intravenous bolus of dexmedetomidine (studies, 3; n = 274; mean difference [MD], -5 [-6 to -4]; P < 0.0001) and during surgical stimulant (studies, 2; n = 153; MD, -11 [-13 to -9]; P < 0.0001). In comparison to the low-dose dexmedetomidine, high-dose dexmedetomidine was also associated with a significant longer recovery time (studies, 3; n = 257; MD, 5.90 [1.56 to 10.23]; P = 0.008) but a lower incidence of emergence agitation (studies, 2; n = 153; odds ratio, 0.17 [0.03 to 0.95]; P = 0.040). In this meta-analysis, low-dose dexmedetomidine demonstrated better hemodynamic stability with shorter recovery time than high-dose dexmedetomidine. However, these findings need to be interpreted with caution due to limited published studies, a small sample size, and a high degree of heterogeneity.
  11. Chaw SH, Shariffuddin II, Foo LL, Lee PK, Paran RM, Cheang PC, et al.
    J Clin Monit Comput, 2018 Dec;32(6):1093-1099.
    PMID: 29404890 DOI: 10.1007/s10877-018-0109-4
    To date, most of the studies on safety and efficacy of supraglottic airway devices were done in Caucasian patients, and the results may not be extrapolated to Asian patients due to the different airway anatomy. We conducted this study to compare Supreme™ LMA (SLMA) and Proseal™ LMA (PLMA) size 1.5 in anaesthetized children among an Asian population. This prospective randomized clinical trial was conducted in a tertiary teaching hospital from September 2013 until May 2016. Sixty children, weighing 5-10 kg, who were scheduled for elective surgery under general anaesthesia were recruited and completed the study. Patients were randomly assigned to have either SLMA or PLMA as the airway device for general anaesthesia, and standard anaesthesia protocol was followed. The primary outcome measured was the oropharyngeal leak pressure (OLP). The rate of successful insertion, insertion time, fibreoptic view of larynx and airway complications for each device were also assessed. There were no statistically significant differences between SLMA and PLMA size 1.5 in oropharyngeal leak pressure [19.1 (± 5.5) cmH2O vs. 19.8 (± 4.5) cmH2O, p = 0.68]. Secondary outcomes including time to insertion [20.8 (± 8.3) vs. 22.1 (± 8.3) s, p = 0.57], first attempt success rate for device insertion, fibreoptic view of larynx, and airway complications were also comparable between the two devices. We found that all the patients who had a failed device insertion (either PLMA or SLMA) were of a smaller size (5-6.2 kg). The oropharyngeal leak pressure of the SLMA 1.5 was comparable with the PLMA 1.5, and both devices were able to maintain an airway effectively without significant clinical complications in anaesthetized children from an Asian population.
  12. Chaw SH, Lo YL, Yeap LL, Haron DEBM, Shariffuddin II
    Eur J Drug Metab Pharmacokinet, 2023 Jan;48(1):11-21.
    PMID: 36207565 DOI: 10.1007/s13318-022-00795-4
    BACKGROUND AND OBJECTIVE: Oxycodone, a semisynthetic thebaine derivative µ-opioid (MOP) receptor agonist, is effective for treating moderate and severe pain in different clinical conditions. The pharmacokinetics of intravenous oxycodone in the obese population has not been studied. This study aims to characterize the pharmacokinetic profile of oxycodone after intravenous administration and to simulate an appropriate dosage for analgesic efficacy in obese patients.

    METHODS: We recruited 33 (age range from 21 to 72 years) adult patients with a body mass index of 30 kg/m2 and above, who were scheduled for non-cardiac surgeries. Intravenous oxycodone was administered after induction of general anesthesia and blood samples were collected up to 24 h after oxycodone administration. Plasma concentrations of oxycodone were assayed using liquid chromatography-tandem mass spectrometry and 253 concentration-time points were used for pharmacokinetic analysis using nonlinear mixed-effects modeling.

    RESULTS: Intravenous oxycodone pharmacokinetics were well described by a two-compartment open model. The estimated total clearance and central volume of distribution of oxycodone are 28.5 l/h per 70 kg and 56.4 l per 70 kg, respectively. Total body weight was identified as a significant covariate of the clearance and central volume of distribution. Dosing simulations based on the final model demonstrate that a starting dose of 0.10 mg/kg of intravenous oxycodone is adequate to achieve a target plasma concentration and repeated doses of 0.02 mg/kg may be administered at 1.5-h intervals to maintain a plasma concentration within an effective analgesic range.

    CONCLUSIONS: A population pharmacokinetic model using total body weight as a covariate supports the administration of 0.10 mg/kg of intravenous oxycodone as a starting dose and repeated doses of 0.02 mg/kg at 1.5-h intervals to maintain targeted plasma concentrations for analgesia in the obese adult population.

  13. Chew WZ, Teoh WY, Sivanesan N, Loh PS, Shariffuddin II, Ti LK, et al.
    J Cardiothorac Vasc Anesth, 2022 Dec;36(12):4449-4459.
    PMID: 36038444 DOI: 10.1053/j.jvca.2022.07.004
    OBJECTIVE: To examine the effect of bispectral index (BIS)-guided anesthesia on the incidence of postoperative delirium (POD) in elderly patients undergoing surgery.

    DESIGN: A systematic review, meta-analysis, and trial sequential analysis (TSA).

    SETTING: In the operating room, postoperative anesthesia care units (PACU), and ward.

    PARTICIPANTS: Elderly patients (>60 years old) undergoing surgery.

    INTERVENTIONS: The EMBASE, MEDLINE, and CENTRAL databases were searched systematically from their inception until December 2020 for randomized controlled trials comparing BIS and usual care or blinded BIS.

    MEASUREMENTS AND MAIN RESULTS: Ten trials (N = 3,891) were included for quantitative meta-analysis. In comparison to the control group, there was no significant difference in the incidence of POD in elderly patients randomized to BIS-guided anesthesia (odds ratio [OR] 0.71, 95% CI 0.47-1.08, I2 = 76%, p = 0.11, level of evidence = very low, TSA = inconclusive). The authors' review demonstrated that elderly patients with BIS-guided anesthesia were significantly associated with a lower incidence of postoperative cognitive dysfunction (POCD) (OR 0.64, 95% CI 0.46-0.88, p = 0.006), extubation time (mean difference [MD] -3.38 minutes, 95% CI -4.38 to -2.39, p < 0.00001), time to eye opening (MD -2.17 minutes, 95% CI -4.21 to -0.14, p = 0.04), and time to discharge from the PACU (MD -10.77 minutes, 95% CI -11.31 to - 10.23, p < 0.00001).

    CONCLUSION: The authors' meta-analysis demonstrated that BIS-guided anesthesia was not associated with a reduced incidence of POD, but it was associated with a reduced incidence of POCD and improved recovery parameters.

  14. Loh PS, Chaw SH, Shariffuddin II, Ng CC, Yim CC, Hashim NHM
    Anesth Analg, 2021 Jan;132(1):15-24.
    PMID: 33002931 DOI: 10.1213/ANE.0000000000005264
    BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic affected and overwhelmed many health care systems around the world at an unprecedented speed and magnitude with devastating effects. In developing nations, smaller hospitals were unprepared to face this outbreak nor had strategies in place to do so at the beginning. Here, we describe the preparation in an anesthetic department using simulation-based training over 2 weeks, as the number of cases rose rapidly.

    METHODS: Three areas of priority were identified as follows: staff safety, patient movement, and possible clinical scenarios based on simulation principles in health care education. Staff was rostered and rotated through stations for rapid-cycle deliberate practice to learn donning and doffing of personal protective equipment (PPE) and powered air-purifying respirator (PAPR). For difficult airway management, Peyton's 4 steps for skills training and Harden's Three Circle model formed the structure in teaching the core skills. Several clinical scenarios used system probing to elicit inadequacies followed by formal debriefing to facilitate reflection. Finally, evaluation was both immediate and delayed with an online survey after 1 month to examine 4 levels of reaction, learning, behavior, and impact based on the Kirkpatrick Model. Frequency and thematic analysis were then conducted on the quantitative and qualitative data, respectively.

    RESULTS: A total of 15 of 16 (93%) consultants, 16 (100%) specialists, and 81 (100%) medical officers in the department completed training within 2 consecutive weeks. Reaction and part of the learning were relayed immediately to trainers during training. In total, 42 (39%) trained staff responded to the survey. All were satisfied and agreed on the relevance of training. A total of 41 respondents (98%; 95% confidence interval [CI], 87-99) answered 16 of 20 questions correctly on identifying aerosol-generating procedures (AGP), indications for PPE, planning and preparation for airway management to achieve adequate learning. About 43% (95% CI, 27-59) and 52% (95% CI, 36-68) recalled donning and doffing steps correctly. A total of 92 responses from 33 respondents were analyzed in the thematic analysis. All respondents reported at least 1 behavioral change in intended outcomes for hand hygiene practice (20%), appropriate use of PPE (27%), and airway management (10%). The emerging outcomes were vigilance, physical distancing, planning, and team communication. Finally, the impact of training led to the establishment of institutional guidelines followed by all personnel.

    CONCLUSIONS: Simulation-based training was a useful preparation tool for small institutions with limited time, resources, and manpower in developing nations. These recommendations represent the training experience to address issues of "when" and "how" to initiate urgent "medical education" during an outbreak.

  15. Rai V, Shariffuddin II, Chan YK, Muniandy RK, Wong KK, Singh S
    BMC Anesthesiol, 2014;14:49.
    PMID: 25002831 DOI: 10.1186/1471-2253-14-49
    BACKGROUND: Complete heart block in pregnancy has serious implications particularly during the period of delivery. This is more so if the delivery is an operative one as the presence of heart block may produce haemodynamic instability in the intra operative period. We report a unique case of a pregnant mother with complete heart block undergoing hysterostomy, complicated by placenta accreta and intrauterine death.

    CASE PRESENTATION: A 37 year old Malaysian Chinese parturient was admitted at 25 weeks gestation following a scan which suggested intrauterine death and placenta accreta. She was diagnosed to have congenital complete heart block after her first delivery eight years previously but a pacemaker was never inserted. These medical conditions make her extremely likely to experience massive bleeding and haemodynamic instability. Among the measures taken to optimise her pre-operatively were the insertion of a temporary intravenous pacemaker and embolization of the uterine arteries to minimize peri-operative blood loss. She successfully underwent surgery under general anesthesia, which was relatively uneventful and was discharged well on the fourth post-operative day.

    CONCLUSION: Congenital heart block in pregnancies in the presence of potential massive bleeding is best managed by a team, with meticulous pre-operative optimization. Suggested strategies would include insertion of a temporary pacemaker and embolization of the uterine arteries to reduce the risk of the patient getting into life threatening situations.

  16. Ng KT, Lim WE, Teoh WY, Shariffuddin II, Ti LK, Abidin MFBZ
    J Anesth, 2024 Feb;38(1):65-76.
    PMID: 38019351 DOI: 10.1007/s00540-023-03281-6
    PURPOSE: Midline approach of spinal anesthesia has been widely used for patients undergoing surgical procedures. However, it might not be effective for obstetric patients and elderly with degenerative spine changes. Primary objective was to examine the success rate at the first attempt between the paramedian and midline spinal anesthesia in adults undergoing surgery.

    METHODS: Databases of MEDLINE, EMBASE, and CENTRAL were searched from their starting date until February 2023. Randomized clinical trials (RCTs) comparing the paramedian versus midline approach of spinal anesthesia were included. The primary outcome was the success rate at the first attempt of spinal anesthesia.

    RESULTS: Our review included 36 RCTs (n = 5379). Compared to the midline approach, paramedian approach may increase success rate at the first attempt but the evidence is very uncertain (OR: 0.47, 95% CI 0.27-0.82, ρ = 0.007, level of evidence:very low). Our pooled data indicates that the paramedian approach likely reduced incidence of post-spinal headache (OR: 2.07, 95% CI 1.51-2.84, ρ 

  17. Kassim M, Mansor M, Kamalden TA, Shariffuddin II, Hasan MS, Ong G, et al.
    Shock, 2014 Aug;42(2):154-60.
    PMID: 24667629 DOI: 10.1097/SHK.0000000000000179
    Excessive free radical production by immune cells has been linked to cell death and tissue injury during sepsis. Peroxynitrite is a short-lived oxidant and a potent inducer of cell death that has been identified in several pathological conditions. Caffeic acid phenethyl ester (CAPE) is an active component of honeybee products and exhibits antioxidant, anti-inflammatory, and immunomodulatory activities. The present study examined the ability of CAPE to scavenge peroxynitrite in RAW 264.7 murine macrophages stimulated with lipopolysaccharide/interferon-γ that was used as an in vitro model. Conversion of 123-dihydrorhodamine to its oxidation product 123-rhodamine was used to measure peroxynitrite production. Two mouse models of sepsis (endotoxemia and cecal ligation and puncture) were used as in vivo models. The level of serum 3-nitrotyrosine was used as an in vivo marker of peroxynitrite. The results demonstrated that CAPE significantly improved the viability of lipopolysaccharide/interferon-γ-treated RAW 264.7 cells and significantly inhibited nitric oxide production, with effects similar to those observed with an inhibitor of inducible nitric oxide synthase (1400W). In addition, CAPE exclusively inhibited the synthesis of peroxynitrite from the artificial substrate SIN-1 and directly prevented the peroxynitrite-mediated conversion of dihydrorhodamine-123 to its fluorescent oxidation product rhodamine-123. In both sepsis models, CAPE inhibited cellular peroxynitrite synthesis, as evidenced by the absence of serum 3-nitrotyrosine, an in vivo marker of peroxynitrite. Thus, CAPE attenuates the inflammatory responses that lead to cell damage and, potentially, cell death through suppression of the production of cytotoxic molecules such as nitric oxide and peroxynitrite. These observations provide evidence of the therapeutic potential of CAPE treatment for a wide range of inflammatory disorders.
  18. Chaw SH, Lo YL, Lee JY, Wong JW, Zakaria WAW, Ruslan SR, et al.
    BMC Anesthesiol, 2021 01 15;21(1):20.
    PMID: 33451283 DOI: 10.1186/s12871-020-01229-x
    BACKGROUND: The Revised American Pain Society Patient Outcome Questionnaire (APS-POQ-R) evaluates the patient-reported quality of pain management in adults. A validated APS-POQ-R is pivotal to guide effective pain management with better patient satisfaction. Previous studies revealed that subscales of "patients' perception of pain management" were unstable cross-culturally. This study aims to evaluate the construct validity of the APS-POQ-R in gynecological postoperative patients with a multi-cultural background using confirmatory factor analysis to allow comparisons among different a priori models at the latent factor level.

    METHODS: Patients aged 18 years old or above and who were scheduled for gynecology surgery were selected. Three different models with a combination of latent factors were based on a priori hypotheses from previous studies. The root-mean-squared error of approximation, comparative fit index, Tucker-Lewis Index, Chi-squared test, and change in Chi-squared statistic given a change in degrees of freedom between models were used to assess the model fit to the present data.

    RESULTS: A total of 302 patients completed the questionnaire. The five-factor model which was based on Gordon's study has an acceptable fit for the data and was superior when compared to the one-factor baseline model. Although the four-factor model, which originated from Botti's study, also demonstrates a good model fit, the "perception of care" construct was excluded in this model. The "perception of care" construct is conceptually important as patient-centered care has become the focus of quality improvement of pain service.

    CONCLUSIONS: The APS-POQ-R is easy to administer and is useful for quality evaluation in postoperative pain management. The present study demonstrates that a five-factor structure of the APS-POQ-R is the best fitting model in our patient sample. The results of this study provide further evidence to support the use of APS-POQ-R as a measurement tool for pain management evaluation in acute postoperative patients with a multi-cultural background.

  19. Shariffuddin II, Chaw SH, Ng LW, Lim CH, Zainal Abidin MF, Wan Zakaria WA, et al.
    BMC Anesthesiol, 2020 07 31;20(1):184.
    PMID: 32736516 DOI: 10.1186/s12871-020-01100-z
    BACKGROUND: The 4th National Audit Project of The Royal College of Anaesthetists and The Difficult Airway Society (NAP4) reported a higher incidence of supraglottic airway device (SAD) related pulmonary aspiration in obese patients especially with the first-generation SADs. The latest single-use SAD, the Protector™ provides a functional separation of the respiratory and digestive tracts and its laryngeal cuff with two ports allowing additional suction in tandem with the insertion of a gastric tube. The laryngeal cuff of LMA Protector™ allows a large catchment reservoir in the event of gastric content aspiration.

    METHODS: We evaluated the performance characteristics of the LMA Protector™ in 30 unparalysed, moderately obese patients. First attempt insertion rate, time for insertion, oropharyngeal leak pressure (OLP), and incidence of complications were recorded.

    RESULTS: We found high first and second attempt insertion rates of 28(93%) and 1(33%) respectively, with one failed attempt where no capnography trace could be detected, presumably from a downfolded device tip. The LMA Protector™ was inserted rapidly in 21.0(4.0) seconds and demonstrated high OLP of 31.8(5.4) cmH2O. Fibreoptic assessment showed a clear view of vocal cords in 93%. The incidence of blood staining on removal of device was 48%, postoperative sore throat 27%, dysphagia 10% and dysphonia 20% (all self-limiting, resolving a few hours postoperatively).

    CONCLUSIONS: We conclude that the LMA Protector™ was associated with easy, expedient first attempt insertion success, demonstrating high oropharyngeal pressures and good anatomical position in the moderately obese population, with relatively low postoperative airway morbidity.

    TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry, ACTRN12617001152314 . Registered 7 August 2017.

  20. Chaw SH, Lo YL, Goh SL, Cheong CC, Tan WK, Loh PS, et al.
    Obes Surg, 2021 10;31(10):4305-4315.
    PMID: 34282569 DOI: 10.1007/s11695-021-05564-x
    BACKGROUND: Transversus abdominis plane (TAP) block and intraperitoneal local anesthetics (IPLA) are widely investigated techniques that potentially improve analgesia after bariatric surgery. The analgesic efficacy of TAP block has been shown in previous studies, but the performance of TAP block can be difficult in patients with obesity. We performed a systematic review and meta-analysis to compare the analgesic efficacy of TAP block and IPLA. An alternative technique is useful in clinical setting when TAP block is not feasible.

    METHODS: We searched PubMed, Embase, and CENTRAL from inception until August 2020 for randomized controlled trials comparing both techniques. The primary outcome was cumulative morphine consumption at 24 h. Secondary pain-related outcomes included pain score at rest and on movement at 2, 6, 12, and 24 h; postoperative nausea and vomiting; and length of hospital stay.

    RESULTS: We included 23 studies with a total of 2,178 patients. TAP block is superior to control in reducing opioid consumption at 24 h, improving pain scores at all the time points and postoperative nausea and vomiting. The cumulative opioid consumption at 24 h for IPLA is less than control, while the indirect comparison between IPLA with PSI and control showed a significant reduction in pain scores at rest, at 2 h, and on movement at 12 h, and 24 h postoperatively.

    CONCLUSIONS: Transversus abdominis plane block is effective for reducing pain intensity and has superior opioid-sparing effect compared to control. Current evidence is insufficient to show an equivalent analgesic benefit of IPLA to TAP block.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links