Displaying all 2 publications

Abstract:
Sort:
  1. James CA, Hayes M, Willmott AGB, Gibson OR, Flouris AD, Schlader ZJ, et al.
    Temperature (Austin), 2017;4(3):314-329.
    PMID: 28944273 DOI: 10.1080/23328940.2017.1333189
    In cool conditions, physiologic markers accurately predict endurance performance, but it is unclear whether thermal strain and perceived thermal strain modify the strength of these relationships. This study examined the relationships between traditional determinants of endurance performance and time to complete a 5-km time trial in the heat. Seventeen club runners completed graded exercise tests (GXT) in hot (GXTHOT; 32°C, 60% RH, 27.2°C WBGT) and cool conditions (GXTCOOL; 13°C, 50% RH, 9.3°C WBGT) to determine maximal oxygen uptake (V̇O2max), running economy (RE), velocity at V̇O2max (vV̇O2max), and running speeds corresponding to the lactate threshold (LT, 2 mmol.l(-1)) and lactate turnpoint (LTP, 4 mmol.l(-1)). Simultaneous multiple linear regression was used to predict 5 km time, using these determinants, indicating neither GXTHOT (R(2) = 0.72) nor GXTCOOL (R(2) = 0.86) predicted performance in the heat as strongly has previously been reported in cool conditions. vV̇O2max was the strongest individual predictor of performance, both when assessed in GXTHOT (r = -0.83) and GXTCOOL (r = -0.90). The GXTs revealed the following correlations for individual predictors in GXTHOT; V̇O2maxr = -0.7, RE r = 0.36, LT r = -0.77, LTP r = -0.78 and in GXTCOOL; V̇O2maxr = -0.67, RE r = 0.62, LT r = -0.79, LTP r = -0.8. These data indicate (i) GXTHOT does not predict 5 km running performance in the heat as strongly as a GXTCOOL, (ii) as in cool conditions, vV̇O2max may best predict running performance in the heat.
  2. Lei TH, Schlader ZJ, Che Muhamed AM, Zheng H, Stannard SR, Kondo N, et al.
    Eur J Appl Physiol, 2020 Apr;120(4):841-852.
    PMID: 32072226 DOI: 10.1007/s00421-020-04322-8
    PURPOSE: Recent studies have determined that ambient humidity plays a more important role in aerobic performance than dry-bulb temperature does in warm environments; however, no studies have kept humidity constant and independently manipulated temperature. Therefore, the purpose of this study was to determine the contribution of dry-bulb temperature, when vapor pressure was matched, on the thermoregulatory, perceptual and performance responses to a 30-min cycling work trial.

    METHODS: Fourteen trained male cyclists (age: 32 ± 12 year; height: 178 ± 6 cm; mass: 76 ± 9 kg; [Formula: see text]: 59 ± 9 mL kg-1 min-1; body surface area: 1.93 ± 0.12 m2; peak power output: 393 ± 53 W) volunteered, and underwent 1 exercise bout in moderate heat (MOD: 34.9 ± 0.2 °C, 50.1 ± 1.1% relative humidity) and 1 in mild heat (MILD: 29.2 ± 0.2 °C, 69.4 ± 0.9% relative humidity) matched for vapor pressure (2.8 ± 0.1 kPa), with trials counterbalanced.

    RESULTS: Despite a higher weighted mean skin temperature during MOD (36.3 ± 0.5 vs. 34.5 ± 0.6 °C, p 

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links