Displaying all 2 publications

Abstract:
Sort:
  1. Sayapathi BS, Rowther S
    Indian J Occup Environ Med, 2022 09 26;26(3):201-203.
    PMID: 36408431 DOI: 10.4103/ijoem.ijoem_314_21
    The diagnosis of occupational noise-induced hearing loss is rarely made in a video editor, although there is a high prevalence of hearing loss. A 37-year-old woman experienced gradual hearing loss associated with tinnitus for the past 3 years. Audiometry showed mild-to-severe sensorineural hearing loss in the right ear and mild-to-moderate sensorineural hearing loss in the left ear. There is a dip at 2 kHz, which is more pronounced in the right ear with recovery at 8 kHz. The portable listening devices risk causing hearing loss from high-output noise damaging the cochlear structures. The amplitudes on otoacoustic emission levels are decreased by using these devices, especially among long-time users. Incessant tinnitus may cause adverse effects on the quality of life. Sound therapy devices such as digital signal processing devices through hearing aids may assist this group of patients by distracting their attention from tinnitus.
  2. Sayapathi BS, Rowther S
    Indian J Occup Environ Med, 2023;27(3):271-273.
    PMID: 38047178 DOI: 10.4103/ijoem.ijoem_314_22
    According to the American Industrial Hygiene Association (AIHA), tests of functional capacity evaluation (FCE) have an insignificant relationship with the actual tasks performed and the on-job assessment is required. Commuting accidents have been an increasing trend. A 34-year-old gentleman was referred following severe traumatic brain injury with cerebral edema and multiple fractures. He was evaluated with the Chessington Occupational Therapy Neurological Assessment Battery (COTNAB) where his visual perception performance has improved. The performance of visual and spoken instructions is within normal limits. He has improved on the upper extremity functional scale measure activities with an affected limb from 60 to 68 and also improved on the lower extremity functional scale from 43 to 51. He managed to cover a distance of 2 km in 42 minutes after a short break and accomplished to climb 200 steps after a mini-break through maximum capacity evaluation. The patient is fit as a clerk after going through various sessions to improve the cognition and function of extremities. FCE is precisely measured behavioral tests and should be inferred from the patient's personal and environmental setting.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links