METHODS: It was a cross-sectional study carried out at Universiti Kebangsaan Malaysia Medical Centre (UKMMC), Malaysia. Records of patients with focal thyroid nodules on ultrasound (US) for which US-guided fine needle aspiration cytology (FNAC) was performed and pathology results were available, from January 2014 to May 2016 were selected for review. Correlation of the U Classification with pathology results was assessed. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, predictive value, negative predictive value and accuracy were calculated in a conservative and non-conservative method. The threshold for statistical performance was set at 0.05. Each sonographic feature was also compared with its pathology results.
RESULTS: A total of 91 patients with 104 nodules were eligible. 12 nodules out of 104 (11.5%) were malignant. The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, positive predictive value, negative predictive value and accuracy were 100%, 91.3%, 11.5, 0.0, 60%, 100% and 92.3%, and 100%, 91.4%, 11.7%, 0.0, 78.6%, 100% and 93.5%, for the non-conservative and conservative method of calculations respectively.
CONCLUSION: The U Classification is reliable in predicting thyroid malignancy. More evidence is nevertheless necessary for widespread adaptation and use.
MATERIALS AND METHODS: This was a cross sectional study with 64 arms from 32 patients (34 neuropathic, 30 nonneuropathic). Diagnosis was confirmed by nerve conduction study and electromyography. The ulnar nerves were evaluated with 15MHz small footprint linear array transducer. The ulnar nerve CSA was measured at three levels with arm extended: at medial epicondyle (ME), 5cm proximal and 5cm distal to ME. Results from the neuropathic and nonneuropathic arms were compared. Independent T-tests and Pearson correlation tests were used. P value of less than 0.05 was considered significant.
RESULTS: Mean CSA values for the UN at levels 5cm proximal to ME, ME and 5cm distal to ME were 0.055, 0.109, 0.045 cm(2) respectively in the neuropathic group and 0.049, 0.075, 0.042 cm2 respectively in the non-neuropathic group. The CSA of the UN at the ME level was significantly larger in the neuropathic group, with p value of 0.005. However, there was no statistical difference between the groups at 5cm proximal and distal to the ME, with p values of 0.10 and 0.35 respectively.
CONCLUSION: There is significant difference in CSA values of the UN at ME between the neuropathic and non-neuropathic groups with mean CSA value above the predetermined 0.10cm(2) cut-off point. High-resolution ultrasonography is therefore useful to diagnose and follow up cases of elbow UNN.