  1. Atan R, Peck L, Prowle J, Licari E, Eastwood GM, Storr M, et al.
    Crit Care Med, 2018 10;46(10):e988-e994.
    PMID: 30074491 DOI: 10.1097/CCM.0000000000003350
    OBJECTIVES: In critically ill patients with acute kidney injury receiving vasopressors, high cytokine levels may sustain the shock state. High cutoff hemofiltration achieves greater cytokine removal in ex vivo and in animal models and may reduce the duration of shock but may also increase albumin losses.

    DESIGN: This was a single-center double-blind randomized controlled trial comparing continuous venovenous hemofiltration-high cutoff to continuous venovenous hemofiltration-standard.

    SETTING: Tertiary care hospital in Australia.

    PATIENTS: Vasopressor-dependent patients in acute kidney injury who were admitted to the ICU.

    INTERVENTIONS: Norepinephrine-free time were calculated in critically ill vasopressor-dependent patients in acute kidney injury, randomized to either continuous venovenous hemofiltration-high cutoff or continuous venovenous hemofiltration-standard.

    MEASUREMENT AND MAIN RESULTS: A total of 76 patients were randomized with the following characteristics (continuous venovenous hemofiltration-high cutoff vs continuous venovenous hemofiltration-standard); median age of 65 versus 70 year, percentage of males 47% versus 68%, and median Acute Physiology and Chronic Health Evaluation scores of 25 versus 23.5. The median hours of norepinephrine-free time at day 7 were 32 (0-110.8) for continuous venovenous hemofiltration-high cutoff and 56 hours (0-109.3 hr) (p = 0.520) for continuous venovenous hemofiltration-standard. Inhospital mortality was 55.6% with continuous venovenous hemofiltration-high cutoff versus 34.2% with continuous venovenous hemofiltration-standard (adjusted odds ratio, 2.49; 95% CI, 0.81-7.66; p = 0.191). There was no significant difference in time to cessation of norepinephrine (p = 0.358), time to cessation of hemofiltration (p = 0.563), and filter life (p = 0.21). Serum albumin levels (p = 0.192) were similar and the median dose of IV albumin given was 90 grams (20-212 g) for continuous venovenous hemofiltration-high cutoff and 80 grams (15-132 g) for continuous venovenous hemofiltration-standard (p = 0.252).

    CONCLUSIONS: In critically ill patients with acute kidney injury, continuous venovenous hemofiltration-high cutoff did not reduce the duration of vasopressor support or mortality or change albumin levels compared with continuous venovenous hemofiltration-standard.

  2. Atan R, Peck L, Visvanathan K, Skinner N, Eastwood G, Bellomo R, et al.
    Int J Artif Organs, 2016 Nov 11;39(9):479-486.
    PMID: 27834446 DOI: 10.5301/ijao.5000527
    PURPOSE: To study the effects of continuous veno-venous hemofiltration (CVVH) with high cut-off filters (CVVH-HCO) on plasma cytokine levels, sieving coefficient and clearance compared to CVVH using standard filters (CVVH-Std) in a nested cohort within a double-blind randomized controlled trial in severe acute kidney injury (AKI) patients.

    METHODS: We measured plasma and post-filter levels of IL-6, TNF-alpha, IL-8, IL-1 beta, RANTES, IL-10, IFN-gamma and IFN-alpha in both study groups. We also measured cytokine levels in the ultrafiltrate and calculated sieving coefficients and clearances.

    RESULTS: By 72 hours of treatment, IL-6 had decreased during both treatments (p = 0.009 and 0.005 respectively). In contrast, IL-10 had decreased with CVVH-Std (p = 0.03) but not CVVH-HCO (p = 0.135). None of the other cytokines showed changes over time. There were also no significant between group differences in plasma levels for each cytokine over the 72-hour treatment period. For all cytokines combined, however, the median sieving coefficient was higher for CVVH-HCO (0.31 vs. 0.16; p = 0.042) as was the mass removal rate by ultrafiltration (p = 0.027). While overall combined cytokine levels had fallen to 62.2% of baseline at 72 hours for CVVH-HCO (p<0.0001) and to 75.9% of baseline with CVVH-Std (p = 0.008) there were no between group differences.

    CONCLUSIONS: CVVH-HCO achieved greater combined sieving coefficient and mass removal rate by ultrafiltration for a group of key cytokines than CVVH-Std. However, this effect did not differentially lower their plasma level over the first 72 hours. Our study does not support the use of CVVH-HCO to lower cytokines in critically ill patients with AKI.

  3. Atan R, Virzi GM, Peck L, Ramadas A, Brocca A, Eastwood G, et al.
    Blood Purif., 2014;37(4):296-303.
    PMID: 25096908 DOI: 10.1159/000363220
    To measure plasma pro-apoptotic and pro-necrotic activity in severe acute kidney injury (AKI) patients within a randomized controlled trial of continuous veno-venous hemofiltration with high cut-off filters (CVVH-HCO) versus standard filters (CVVH-Std).