Displaying all 6 publications

Abstract:
Sort:
  1. Mohd Yusop AY, Xiao L, Fu S
    Data Brief, 2019 Aug;25:104234.
    PMID: 31384643 DOI: 10.1016/j.dib.2019.104234
    This paper presents the data on the optimisation and validation of a liquid chromatography-high-resolution mass spectrometry (LC-HRMS) to establish the presence of phosphodiesterase 5 (PDE5) inhibitors and their analogues as adulterants in instant coffee premixes. The method development data covered chromatographic optimisation for better analyte separation and isomeric resolution, mass spectrometry optimisation for high sensitivity and sample preparation optimisation for high extraction recovery (RE) and low matrix effect (ME). The validation data covered specificity, linearity, range, accuracy, limit of detection, limit of quantification, precisions, ME, and RE. The optimisation and validation data presented here is related to the article: "Determination of phosphodiesterase 5 (PDE5) inhibitors in instant coffee premixes using liquid chromatography-high-resolution mass spectrometry (LC-HRMS)" Mohd Yusop et al., 2019.
  2. Mohd Yusop AY, Xiao L, Fu S
    Talanta, 2019 Nov 01;204:36-43.
    PMID: 31357306 DOI: 10.1016/j.talanta.2019.05.078
    As a widely consumed beverage, coffee tends to be a target for intentional adulteration. This study describes the application of modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) coupled to liquid chromatography-high-resolution mass spectrometry (LC-HRMS) for simultaneous screening, identification, and quantification of undeclared phosphodiesterase 5 (PDE5) inhibitors in instant coffee premixes (ICPs). The mass spectrometer was operated in auto MS/MS acquisition for simultaneous MS and MS/MS experiments. Qualitative establishments from the suspected-target screening and targeted identification processes led to an unambiguous analyte assignment from the protonated molecule ([M+H]+) precursor ion which is subsequently used for quantification of 23 targeted PDE5 inhibitors. The analytical method validation covered specificity, linearity, range, accuracy, limit of detection (LOD), limit of quantification (LOQ), precisions, matrix effect (ME), and extraction recovery (RE). The specificity was established using the optimised chromatographic separation as well as the distinguishable [M+H]+ precursor ion. The linearity of each target analyte was demonstrated with a coefficient of determination (r2) of >0.9960 over the expected range of sample concentrations. The accuracy ranged from 88.1%-119.3% with LOD and LOQ of <70 ng/mL and 80 ng/mL, respectively. Excellent precisions were established within 0.4%-9.1% of the relative standard deviation. An insignificant ME within -5.2% to +8.7% was achieved using three different strategies of chromatography, sample extraction, and sample dilution. The RE was good for all target analytes within 84.7%-123.5% except for N-desethylacetildenafil at low (53.8%) and medium (65.1%) quality control levels. The method was successfully applied to 25 samples of ICPs where 17 of them were found to be adulterated with PDE5 inhibitors and their analogues. Further quantification revealed the total amount of these adulterants ranged from 2.77 to 121.64 mg per sachet.
  3. Mohd Yusop AY, Xiao L, Fu S
    Drug Test Anal, 2021 May;13(5):965-976.
    PMID: 32441056 DOI: 10.1002/dta.2861
    The lucrative market of herbal remedies spurs rampant adulteration, particularly with pharmaceutical drugs and their unapproved analogues. A comprehensive screening strategy is, therefore, warranted to detect these adulterants and, accordingly, to safeguard public health. This study uses the data-dependent acquisition of liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QTOF-MS) to screen phosphodiesterase 5 (PDE5) inhibitors in herbal remedies using suspected-target and non-targeted strategies. For the suspected-target screening, we used a library comprising 95 PDE5 inhibitors. For the non-targeted screening, we adopted top-down and bottom-up approaches to flag novel PDE5 inhibitor analogues based on common fragmentation patterns. LC-QTOF-MS was optimised and validated for capsule and tablet dosage forms using 23 target analytes, selected to represent different groups of PDE5 inhibitors. The method exhibited excellent specificity and linearity with limit of detection and limit of quantification of <40 and 80 ng/mL, respectively. The accuracy ranged from 79.0% to 124.7% with a precision of <14.9% relative standard deviation. The modified, quick, easy, cheap, effective, rugged, and safe extraction provided insignificant matrix effect within -9.1%-8.0% and satisfactory extraction recovery of 71.5%-105.8%. These strategies were used to screen 52 herbal remedy samples that claimed to enhance male sexual performance. The suspected-target screening resulted in 33 positive samples, revealing 10 target analytes and 2 suspected analytes. Systematic MS and tandem MS interrogations using the non-targeted screening returned insignificant signals, indicating the absence of potentially novel analogues. The target analytes were quantified from 0.03 to 121.31 mg per dose of each sample. The proposed strategies ensure that all PDE5 inhibitors are comprehensively screened, providing a useful tool to curb the widespread adulteration of herbal remedies.
  4. Mohd Yusop AY, Xiao L, Fu S
    Drug Test Anal, 2021 May;13(5):953-964.
    PMID: 32959983 DOI: 10.1002/dta.2926
    The surge in the consumption of food products containing herbal aphrodisiacs has driven their widespread adulteration. A rapid screening strategy is, therefore, warranted to curb this problem. This study established an enzyme inhibition assay to screen phosphodiesterase 5 (PDE5) inhibitors as adulterants in selected food products. Fluorescein-labelled cyclic-3',5'-guanosine monophosphate was utilised as substrates for the PDE5A1 enzyme, aided by the presence of nanoparticle phosphate-binding beads on their fluorescence polarisation. The sample preparation was optimised to improve the enzyme inhibition efficiency and applied to calculate the threshold values of six blank food matrices. The assay was validated using sildenafil, producing an IC50 of 4.2 nM. The applicability of the assay procedure was demonstrated by screening 55 distinct food samples. The results were subsequently verified using confirmatory liquid chromatography-high-resolution mass spectrometry (LC-HRMS) analysis. Altogether, 49 samples inhibited the PDE5 enzyme above the threshold values (75.7%-105.5%) and were registered as potentially adulterated samples. The remaining six samples were marked as nonadulterated with percentage inhibition below the threshold values (-3.3%-18.2%). The LC-HRMS analysis agreed with the assay results for all food products except for the instant coffee premix (ICP) samples. False-positive results were obtained for the ICP samples at 32% (8/25), due to possible PDE5 inhibition by caffeine. Contrarily, all other food samples were found to produce 0% (0/30) false-positive or false-negative results. The broad-based assay, established via a simple mix-incubate-read format, exhibited promising potential for high-throughput screening of PDE5 inhibitors in various food products, except those with naturally occurring phosphodiesterase inhibitors such as caffeine.
  5. Mohd Yusop AY, Xiao L, Fu S
    Forensic Sci Int, 2021 May;322:110748.
    PMID: 33711768 DOI: 10.1016/j.forsciint.2021.110748
    The presence of erectile dysfunction (ED) drugs in adulterated dietary supplements, mainly in pharmaceutical dosage forms, is frequently addressed in the literature. Little attention is given to food products despite their increasing adulteration trend. To address this knowledge gap targeted, suspected-target, and non-targeted strategies were utilised to analyse ED drugs and their analogues in powdered drink mix (PDM), honey, jelly, hard candy, and sugar-coated chewing gum using liquid chromatography-high-resolution mass spectrometry (LC-HRMS). The method was optimised and validated using 23 target analytes, representing different ED drugs with structural similarities. The modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction exhibited insignificant matrix effect (ME) within - 9.2-8.8% and provided complete coverage of target analytes with acceptable extraction recovery (RE) within 75.5-123.9%, except for carbodenafil in the PDM matrix. Based on the ME and RE performance, the analytical method was validated to analyse 25 food samples that claimed to enhance male sexual performance. The method exhibited good specificity and linearity with a limit of detection within 10-70 ng/mL and limit of quantification of 80 ng/mL. Similarly, the accuracy and precision were satisfactory within 77.4-122.0% and
  6. Nisbar ND, Jamal Khair SK, Bujang NB, Mohd Yusop AY
    Sci Rep, 2023 Jun 10;13(1):9478.
    PMID: 37301842 DOI: 10.1038/s41598-023-36283-1
    The Coronavirus Disease-2019 (COVID-19) outbreak is an unprecedented global pandemic, sparking grave public health emergencies. One of the measures to reduce COVID-19 transmissions recommended by the World Health Organization is hand hygiene, i.e., washing hands with soap and water or disinfecting them using an alcohol-based hand sanitiser (ABHS). Unfortunately, competing ABHSs with unknown quality, safety, and efficacy thrived, posing yet another risk to consumers. This study aims to develop, optimise, and validate a gas chromatography-mass spectrometry (GC-MS)-based analytical method to simultaneously identify and quantify ethanol or isopropyl alcohol as the active ingredient in ABHS, with simultaneous determination of methanol as an impurity. The GC-MS was operated in Electron Ionisation mode, and Selected Ion Monitoring was chosen as the data acquisition method for quantitation. The analytical method was validated for liquid and gel ABHSs, covering the specificity, linearity and range, accuracy, and precisions, including the limit of detection and the limit of quantitation. The specificity of each target analyte was established using the optimised chromatographic separation with unique quantifier and qualifier ions. The linearity was ascertained with a coefficient of determination (r2) of > 0.9994 over the corresponding specification range. Respectively, the accuracy and precisions were satisfactory within 98.99 to 101.09% and 