Application of gas chromatography-triple quadrupole mass spectrometry for identification, confirmation and quantification of 6 phosphodiesterase-5 (PDE-5) inhibitors (sildenafil, dimethylsildenafil, homosildenafil, thiosildenafil, thiodimethylsildenafil and thiohomosildenafil) in dietary supplements was investigated. The MS was operated in multiple reaction monitoring mode, for better sensitivity and selectivity. In this manner, the method is adequate to reduce background noise with less interference from co-eluting compounds in the samples. Two different ionisation techniques, electron ionisation (EI) and chemical ionisation (CI), were studied and compared. The chromatographic separation was performed on a short 10 m non-polar capillary column without any derivatisation step. This permitted fast analysis for all analogues with retention time less than 11 min, for both techniques. Use of backflushing can aid method retention time reduction and improves column maintenance. Evaluation of method validation included limit of detection (LOD), lower limit of quantitation (LLOQ), linearity, precision and recovery were performed for both EI and CI techniques. The LOD obtained varied from 0.03 to 1.50 μg/g and the LLOQ ranged from 0.10 to 5.00 μg/g. Good calibration linearity was obtained for all analogues for both techniques, with correlation coefficients (r(2)) higher than 0.99. Mean recoveries of all analogues using CI show higher values (83.4-108.8%) than that of EI (61.9-91.1%). The intra- and inter-assay precisions were evaluated for all analogues at spiked concentration of 10 μg/g and the relative standard deviation was less than 15% for both methods. These methods were then successfully applied to dietary supplement samples without prior derivatisation, confirming that the samples were adulterated with sildenafil and/or its analogues.
A novel sequential three-dimensional gas chromatography-high-resolution time-of-flight mass spectrometry (3D GC-accTOFMS) approach for profiling secondary metabolites in complex plant extracts is described. This integrated system incorporates a nonpolar first-dimension (1Dnp) separation step, prior to a microfluidic heart-cut (H/C) of a targeted region(s) to a cryogenic trapping device, directly followed by the rapid reinjection of a trapped solute into a polar second-dimension (2DPEG) column for multidimensional separation (GCnp-GCPEG). For additional separation, the effluent from 2DPEG can then be modulated according to a comprehensive 2D GC process (GC×GC), using an ionic liquid phase as a third-dimension (3DIL) column, to produce a sequential GCnp-GCPEG×GCIL separation. Thus, the unresolved or poorly resolved components, or regions that require further separation, can be precisely selected and rapidly transferred for additional separation on 2D or 3D columns, based on the greater separation realized by these steps. The described integrated system can be used in a number of modes, but one useful approach is to target specific classes of compounds for improved resolution. This is demonstrated through the separation and detection of the oxygenated sesquiterpenes in hop ( Humulus lupulus L.) essential oil and agarwood ( Aquilaria malaccensis) oleoresin. Improved resolution and peak capacity were illustrated through the progressive comparison of the tentatively identified components for GCnp-GCPEG and GCnp-GCPEG×GCIL methods. Relative standard deviations of intraday retentions (1 tR, 2 tR,, and 3 tR) and peak areas of ≤0.01, 0.07, 0.71, and 7.5% were achieved. This analytical approach comprising three GC column selectivities, hyphenated with high-resolution TOFMS detection, should be a valuable adjunct for the improved characterization of complex plant samples, particularly in the area of plant metabolomics.
This study investigated the volatile phytochemical diversity of 30 samples obtained from experimental hybrid and commercial H. lupulus L. plants. Essential oils distilled from these samples were analysed by high resolution gas chromatography coupled with accurate mass time-of-flight mass spectrometry (GC-accTOFMS). A total of 58 secondary metabolites, mainly comprising 18 esters, 6 monoterpene hydrocarbons, 2 oxygenated monoterpenes, 20 sesquiterpene hydrocarbons, 7 oxygenated sesquiterpenes, and 4 ketones, were positively or tentatively identified. A total of 24 metabolites were detected in all samples, but commercial cultivars (selected for brewing performance) had fewer compounds identified compared to experimental genotypes. Chemometrics analyses enabled distinct differentiation of experimental hybrids from commercial cultivars, discussed in terms of the different classes of compounds present in different genotypes. Differences among the mono- and sesquiterpenoids, appear to be related to either: i) the genetic origin of the plants; or ii) the processes of bioaccumulation of the identified secondary metabolites.
Real-time interconversion processes produce unconventional peak broadening in gas chromatography (GC), and can be used to generate kinetic and thermodynamic data. In this study, an unusual separation situation in comprehensive two dimensional GC where two dimensional interconversion (i.e. a raised plateau in both first and second dimension, 1D and 2D) was observed in analysis of oxime isomers. This resulted in a characteristic and unusual rectangular peak shape in the two dimensional result. A related theoretical approach was introduced to explain the peak shape supported by simulation results which can be varied depending on concentration profiles and kinetics of the process. The simulated results were supported by experimental results obtained by a comprehensive heart-cut multidimensional GC (H/C MDGC) approach which was developed to clearly investigate isomerisation of E/Z oxime molecules in both 1D and 2D separations under different isothermal conditions. The carrier gas flow and oven temperature were selected according to initial results for 1D interconversion on a poly(ethyleneglycol) stationary phase, which was further used in both 1D and 2D separations to result in broad zones of oxime interconversion in both dimensions. The method involved repetitive injections of oxime sample, then sampling contiguous fractions of sample into a long 2D column which is intended to promote considerable interconversion. Comprehensiveness arises from the fact that the whole sample is sampled from the 1D to the 2D column, with the long 2D column replacing the short 2D column used in classical comprehensive two-dimensional gas chromatography, where the latter will not promote sufficient interconversion. Data processing and presentation permits a 'rectangular' distribution corresponding to the separated compounds, characteristic of this experiment.
This study investigated the effect of heat treatments on the pungency and aroma profiles of a spice oleoresin blend, and the emulsion stability with different surfactants, encapsulating agents, and homogenization mechanisms. Total pungency increased with heat until 120 °C and drastically reduced at 150 °C. Thermal processing induced aroma release, and 46 compounds were identified at 90 °C, predominantly comprising sesquiterpenes. Tween 80 dispersed the highest oleoresin mass (6.21 ± 0.31 mg/mL) and reported the maximum emulsion stability index. The oleoresin percentage significantly influenced the emulsion stability, with 1% oleoresin producing the most stable emulsion. High-pressure homogenization applied on gum Arabic resulted in a greater encapsulation efficiency, exceeding 86%, and the lowest creaming index (4.70 ± 0.06%), while Hi-Cap 100 produced the best flow properties. The findings provide insights into incorporating lipophilic spice oleoresin blends in aqueous food systems and understanding the release of flavor compounds during thermal food processing.
Metabolic profiling of Glycyrrhiza glabra using comprehensive two-dimensional liquid chromatography (LC × LC) coupled with photodiode array (PDA) and mass spectrometry (MS) detection is described. The separation was conducted under reversed-phase conditions, using a combination of first dimension (1 D) 150 mm microbore cyano column utilising 2.7 μm diameter (dp ) particles, and second dimension (2 D) 50 mm superficially porous octadecylsilica column with 2.7 μm dp particles. A multi-segmented shift gradient (MSG) for the 2 D separation was developed, and the orthogonality achieved was compared with other modes of gradients, such as full in-fraction, and shift gradient systems. Results demonstrated a significant expansion of metabolic coverage using MSG in 2 D, providing the highest measure of orthogonality compared to other gradient modes. Compound identifications were performed by employing complementary data from PDA and MS detection, with reference to structural group-type distribution in 2D space. A total of ca. 120 compounds were detected, and among them 37 were tentatively identified, distributed over the chemical families of glycosylated flavanones, triterpene saponins, and others. In comparison with one-dimensional LC, the total number of compounds detected was ca. 2-fold greater when LC × LC was employed. To the best of our knowledge, this is the first demonstration of the MSG mode in LC × LC, representing a powerful strategy to expand the metabolic coverage for analysis of plant-derived extracts, containing a multitude of different phytochemical classes.