Displaying all 2 publications

Abstract:
Sort:
  1. Sethi B, Al-Rubeaan K, Unubol M, Mabunay MA, Berthou B, Pilorget V, et al.
    Diabetes Ther, 2022 Jul;13(7):1395-1408.
    PMID: 35713873 DOI: 10.1007/s13300-022-01271-7
    INTRODUCTION: The efficacy and safety of switching to insulin glargine 300 U/mL (Gla-300) in type 2 diabetes mellitus (T2DM) uncontrolled on basal insulin (BI) has been demonstrated in the North American and Western European populations; however, there is limited data from other geographical regions with different ethnicities. The ARTEMIS-DM study aimed to evaluate the efficacy and safety of Gla-300 in people with T2DM uncontrolled on BI from Asia, Latin America and Middle East Africa.

    METHODS: The ARTEMIS-DM was a 26-week, prospective, interventional, single-arm, phase IV study (NCT03760991). Adults with T2DM previously uncontrolled (glycated haemoglobin [HbA1c] 7.5-10%) on BI were switched to Gla-300. The primary endpoint was change in HbA1c from baseline to 26 weeks. Key secondary endpoints were changes in HbA1c (week 12), fasting plasma glucose (FPG), self-monitored plasma glucose (SMPG) and BI dose from baseline to week 26. The safety and tolerability of Gla-300 were also assessed.

    RESULTS: A total of 372 (50% male) participants were included, with mean (standard deviation [SD]) age 60.9 (10.0) years, duration of diabetes 13.11 (7.48) years and baseline HbA1c 8.67 (0.77)% (71.22 [8.44] mmol/mol). A total of 222 (59.7%) participants were using insulin glargine 100 U/mL and 107 (28.8%) were using neutral protamine Hagedorn insulin as previous BI. There were clinically significant reductions in mean HbA1c (- 0.82%; primary endpoint), FPG and SMPG levels at week 26. With a pre-defined titration algorithm, mean Gla-300 dose increased from 27.48 U (0.35 U/kg) at baseline to 39.01 U (0.50 U/kg) at week 26. Hypoglycaemia events occurred in 20.4% of the participants; 1 (0.3%) participant had a severe hypoglycaemia event.

    CONCLUSION: In people with T2DM uncontrolled on previous BI, switching to Gla-300 with optimal titration guided by an algorithm was associated with improved glycaemic control and low incidence of hypoglycaemia across multiple geographic regions.

    GOV IDENTIFIER: NCT03760991.

  2. Deerochanawong C, Bajpai S, Dwipayana IMP, Hussein Z, Mabunay MA, Rosales R, et al.
    Diabetes Ther, 2017 Dec;8(6):1197-1214.
    PMID: 29094298 DOI: 10.1007/s13300-017-0322-z
    Various data have demonstrated inadequate glycemic control amongst Asians with type 2 diabetes mellitus (T2DM), possibly on account of suboptimal titration of basal insulin-an issue which needs to be further examined. Here we review the available global and Asia-specific data on titration of basal insulin, with a focus on the use of insulin glargine 100 U/mL (Gla-100). We also discuss clinical evidence on the efficacy and safety of titrating Gla-100, different approaches to titration, including some of the latest technological advancements, and guidance on the titration of basal insulin from international and local Asian guidelines. The authors also provide their recommendations for the initiation and titration of basal insulin for Asian populations. Discussion of the data included in this review and in relation to the authors' clinical experience with treating T2DM in Asian patients is also included. Briefly, clinical studies demonstrate the achievement of adequate glycemic control in adults with T2DM through titration of Gla-100. However, studies investigating approaches to titration, specifically in Asian populations, are lacking and need to be conducted. Given that the management of insulin therapy is a multidisciplinary team effort involving endocrinologists, primary care physicians, nurse educators, and patients, greater resources and education targeted at these groups are needed regarding the optimal titration of basal insulin. Technological advancements in the form of mobile or web-based applications for automated dose adjustment can aid different stakeholders in optimizing the dose of basal insulin, enabling a larger number of patients in Asia to reach their target glycemic goals with improved outcomes.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links