METHOD: A meta-analysis was conducted to determine the potential impact of isometric exercise on IOP and OPP. The literature on the relationship between isometric resistance exercise and IOP was systematically searched according to the "Cochrane Handbook" in the databases of Pubmed, Web of Science, EBSCO, and Scopus through December 31, 2020. The search terms used were "exercise," "train," "isometric," "intraocular pressure," and "ocular perfusion pressure," and the mean differences of the data were analyzed using the Stata 16.0 software, with a 95% confidence interval.
RESULTS: A total of 13 studies, which included 268 adult participants consisting of 162 men and 106 women, were selected. All the exercise programs that were included were isometric resistance exercises of the lower limbs with intervention times of 1min, 2min, or 6min. The increase in IOP after intervention was as follows: I2=87.1%, P=0.001 using random-effects model combined statistics, SMD=1.03 (0.48, 1.59), and the increase in OPP was as follows: I2=94.5%, P=0.001 using random-effects model combined statistics, SMD=2.94 (1.65, 4.22), with both results showing high heterogeneity.
CONCLUSION: As isometric exercise may cause an increase in IOP and OPP, therefore, people with glaucoma and related high risk should perform isometric exercise with caution.
MATERIALS AND METHODS: The study was performed on Varian Clinac iX, Elekta Synergy S, Siemens Oncor, and Tomotherapy. A CT phantom (Catphan-504, Phantom Laboratory, Salem, NY) was scanned for measurements of image quality including image noise, uniformity, density accuracy, spatial resolution, contrast linearity, and contrast resolution. The measurement results were analysed using in-house image analysis software. Reproducibility, position correction, and geometric accuracy were also evaluated with markers in a smaller alignment phantom. The performance evaluation compared volumetric image properties from these four systems with those from a conventional diagnostic CT (CCT).
RESULTS: It was shown that the linearity of the two kV CBCT was fairly consistent with CCT. The Elekta CBCT with half-circle 27-cm FOV had higher CT numbers than the other three systems. The image noises of the Elekta kV CBCT, Siemens MV CBCT, and Tomotherapy fan-beam CT (FBCT) are about 2-4 times higher than that of the Varian CBCT. The spatial resolutions of two kV CBCTs and two MV CBCTs were 8-11 lp/cm and 3-5 lp/cm, respectively.
CONCLUSION: Elekta CBCT provided a faster image reconstruction and low dose per scan for half-circle scanning. Varian CBCT had relatively lower image noise. Tomotherapy FBCT had the best uniformity.
DESIGN: A meta-analysis was conducted to determine the potential impact of blood flow restriction on patients with knee injuries. PubMed, EBSCO, and Web of Science databases were searched for eligible studies from January 2000 until January 2020. The mean differences of the data were analyzed using Revman 5.3 software with a 95% confidence interval.
RESULTS: Nine studies fulfilled the inclusion criteria. These studies involved 179 patients who received L-BFR, 96 patients who underwent high-load resistance training, and another 94 patients who underwent low-load resistance training. The analysis of pooled data showed that patients in both the L-BFR (standardized mean difference, 0.83 [0.53, 1.14], P < 0.01) and high-load resistance training (standardized mean difference, -0.09 [-0.43, 0.24], P = 0.58) groups experienced an increase in muscle strength after the training. In addition, pain score was significantly reduced in the L-BFR group compared with the other two groups (standardized mean difference, -0.61 [-1.19, -0.03], P = 0.04).
CONCLUSIONS: Muscle strength increased after L-BFR and high-load resistance training compared with low-load resistance training. Furthermore, pain score was significantly reduced after L-BFR. Hence, L-BFR is a potential intervention to be applied in rehabilitation of knee injuries.