Displaying all 4 publications

Abstract:
Sort:
  1. Ooi, Ching Sheng, Lim, Meng Hee, Lee, Kee Quen, Kang, Hooi Siang, Mohd Salman Leong
    MyJurnal
    Previous studies have indicated that the pipe-surface-mounted helical strakes effectively reduce vortex-induced vibration (VIV) under a uniform flow application, particularly during the lock-in region. Since VIV experiments are time-consuming, observation is generated with an interval helical strakes parameter in pitch and height to lessen tedious procedures and repetitive post-processing analyses. The aforementioned result subset is insufficient for helical strakes design optimisation because the trade-off between the helical strakes dimension, lock-in region and flow velocity are non-trivial. Thus, a parametric model based on an improved recursive least squares (RLS) parameter estimation technique is proposed to define the statistical relationship between input, or strakes and pipe dimension, and output, or VIV amplitude ratio. As results suggested, revised RLS estimated VIV model demonstrated an optimal prediction with the highest coefficient of determination and lowest Integral Absolute Error. The feasibility of VIV parametric model was validated by embed into Genetic Algorithm (GA) as the fitness function to acquire a desirable helical strakes dimension with minimum VIV amplitude. The rapid generation of optimal helical strakes dimension which returned the highest VIV suppression implied a superior simulation method compared to the experimental outcome.
  2. Kek HY, Tan H, Othman MHD, Lee CT, Ahmad FBJ, Ismail ND, et al.
    Environ Res, 2024 Apr 16.
    PMID: 38636646 DOI: 10.1016/j.envres.2024.118928
    Microplastics (MPs), as emerging indoor contaminants, have garnered attention due to their ubiquity and unresolved implications for human health. These tiny particles have permeated indoor air and water, leading to inevitable human exposure. Preliminary evidence suggests MP exposure could be linked to respiratory, gastrointestinal, and potentially other health issues, yet the full scope of their effects remains unclear. To map the overall landscape of this research field, a bibliometric analysis based on research articles retrieved from the Web of Science database was conducted. The study synthesizes the current state of knowledge and spotlights the innovative mitigation strategies proposed to curb indoor MP pollution. These strategies involve minimizing the MP emission from source, advancements in filtration technology, aimed at reducing the MP exposure. Furthermore, this research sheds light on cutting-edge methods for converting MP waste into value-added products. These innovative approaches not only promise to alleviate environmental burdens but also contribute to a more sustainable and circular economy by transforming waste into resources such as biofuels, construction materials, and batteries. Despite these strides, this study acknowledges the ongoing challenges, including the need for more efficient removal technologies and a deeper understanding of MPs' health impacts. Looking forward, the study underscores the necessity for further research to fill these knowledge gaps, particularly in the areas of long-term health outcomes and the development of standardized, reliable methodologies for MP detection and quantification in indoor settings. This comprehensive approach paves the way for future exploration and the development of robust solutions to the complex issue of microplastic pollution.
  3. Tan H, Wong KY, Othman MHD, Kek HY, Wahab RA, Ern GKP, et al.
    Environ Sci Pollut Res Int, 2022 Nov;29(53):80137-80160.
    PMID: 36194323 DOI: 10.1007/s11356-022-23407-9
    An indoor environment in a hospital building requires a high indoor air quality (IAQ) to overcome patients' risks of getting wound infections without interrupting the recovery process. However, several problems arose in obtaining a satisfactory IAQ, such as poor ventilation design strategies, insufficient air exchange, improper medical equipment placement and high door opening frequency. This paper presents an overview of various methods used for assessing the IAQ in hospital facilities, especially in an operating room, isolation room, anteroom, postoperative room, inpatient room and dentistry room. This review shows that both experimental and numerical methods demonstrated their advantages in the IAQ assessment. It was revealed that both airflow and particle tracking models could result in different particle dispersion predictions. The model selection should depend on the compatibility of the simulated result with the experimental measurement data. The primary and secondary forces affecting the characteristics of particle dispersion were also discussed in detail. The main contributing forces to the trajectory characteristics of a particle could be attributed to the gravitational force and drag force regardless of particle size. Meanwhile, the additional forces could be considered when there involves temperature gradient, intense light source, submicron particle, etc. The particle size concerned in a healthcare facility should be less than 20 μm as this particle size range showed a closer relationship with the virus load and a higher tendency to remain airborne. Also, further research opportunities that reflect a more realistic approach and improvement in the current assessment approach were proposed.
  4. Tan H, Mong GR, Wong SL, Wong KY, Sheng DDCV, Nyakuma BB, et al.
    Environ Sci Pollut Res Int, 2024 Jan;31(1):109-126.
    PMID: 38040882 DOI: 10.1007/s11356-023-31228-7
    This paper presents the landscape of research on airborne microplastics and nanoplastics (MPs/NPs) according to the bibliometric analysis of 147 documents issued between 2015 and 2021, extracted from the Web of Science database. The publications on airborne MPs/NPs have increased rapidly from 2015 onwards, which is largely due to the existence of funding support. Science of the Total Environment is one of the prominent journals in publishing related papers. China, England, the USA, and European Countries have produced a significant output of airborne MP/NP research works, which is associated with the availability of funding agencies regionally or nationally. The research hotspot on the topic ranges from the transport of airborne MPs/NPs to their deposition in the terrestrial or aquatic environments, along with the contamination of samples by indoor MPs/NPs. Most of the publications are either research or review papers related to MPs/NPs. It is crucial to share the understanding of global plastic pollution and its unfavorable effects on humankind by promoting awareness of the existence and impact of MPs/NPs. Funding agencies are vital in boosting the research development of airborne MPs/NPs. Some countries that are lacking funding support were able to publish research findings related to the field of interest, however, with lesser research output. Without sufficient fundings, some impactful publications may not be able to carry a substantial impact in sharing the findings and discoveries with the mass public.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links