Displaying all 4 publications

Abstract:
Sort:
  1. Krishnan, Jagannathan, Siti Rabiatul Adawiyah Ibrahim
    MyJurnal
    Mixed microbial culture used in this study was developed from sludge that was taken from local textile wastewater treatment tank. Acclimatization process was performed before starting the biodegradation experiment to obtain a microbial culture with high degradation properties. Kinetic studies by the mixed microbial culture were determined quantitatively for the model pollutant, Reactive Black 5 (RB 5). By using Michaelis-Menten model, the constants were found to be 11.15 mg l-1 h -1 and 29.18 mg l-1 for Vm and Km respectively. The values of kinetic constants for Monod model were found to be 33.11 mg l-1 cell h-1 for the maximum specific microbial growth rate, µm and 86.62 mg l-1 for Monod constant, Ks. The effects of process parameters such as pH, inoculum size and initial dye concentration on the biodegradation of azo dye, RB 5 were systematically investigated. Maximum removal efficiencies observed in this study were 75% for pH 6, 100% for 15% inoculum concentration and 75% for 20 ppm of initial dye concentration.
  2. Mohd Sauid S, Krishnan J, Huey Ling T, Veluri MV
    Biomed Res Int, 2013;2013:409675.
    PMID: 24350269 DOI: 10.1155/2013/409675
    Volumetric mass transfer coefficient (kLa) is an important parameter in bioreactors handling viscous fermentations such as xanthan gum production, as it affects the reactor performance and productivity. Published literatures showed that adding an organic phase such as hydrocarbons or vegetable oil could increase the kLa. The present study opted for palm oil as the organic phase as it is plentiful in Malaysia. Experiments were carried out to study the effect of viscosity, gas holdup, and kLa on the xanthan solution with different palm oil fractions by varying the agitation rate and aeration rate in a 5 L bench-top bioreactor fitted with twin Rushton turbines. Results showed that 10% (v/v) of palm oil raised the kLa of xanthan solution by 1.5 to 3 folds with the highest kLa value of 84.44 h(-1). It was also found that palm oil increased the gas holdup and viscosity of the xanthan solution. The kLa values obtained as a function of power input, superficial gas velocity, and palm oil fraction were validated by two different empirical equations. Similarly, the gas holdup obtained as a function of power input and superficial gas velocity was validated by another empirical equation. All correlations were found to fit well with higher determination coefficients.
  3. Kumar SN, Omar B, Htwe O, Joseph LH, Krishnan J, Jafarzedah Esfehani A, et al.
    J Rehabil Res Dev, 2014;51(4):591-8.
    PMID: 25144172 DOI: 10.1682/JRRD.2013.07.0166
    Limb loading measurements serve as an objective evaluation of asymmetrical weight bearing in the lower limb. Digital weighing scales (DWSs) could be used in clinical settings for measurement of static limb loading. However, ambiguity exists whether limb loading measurements of DWSs are comparable with a standard tool such as MatScan. A cross-sectional study composed of 33 nondisabled participants was conducted to investigate the reliability, agreement, and validity of DWSs with MatScan in static standing. Amounts of weight distribution and plantar pressure on the individual lower limb were measured using two DWSs (A, B) and MatScan during eyes open (EO) and eyes closed (EC) conditions. The results showed that intra- and interrater reliability (3, 1) were excellent (0.94-0.97) within and between DWS A and B. Bland-Altman plot revealed good agreement between DWS and MatScan in EO and EC conditions. The area under the receiver operating characteristic curve was significant and identified as 0.68 (p = 0.01). The measurements obtained with DWSs are valid and in agreement with MatScan measurements. Hence, DWSs could be used interchangeably with MatScan and could provide clinicians an objective measurement of limb loading suitable for clinical settings.
  4. Rene ER, Kar S, Krishnan J, Pakshirajan K, López ME, Murthy DV, et al.
    Bioresour Technol, 2015 Aug;190:529-35.
    PMID: 25827361 DOI: 10.1016/j.biortech.2015.03.049
    The performance of a compost biofilter inoculated with mixed microbial consortium was optimized for treating a gas-phase mixture of benzene and toluene. The biofilter was acclimated to these VOCs for a period of ∼18d. The effects of concentration and flow rate on the removal efficiency (RE) and elimination capacity (EC) were investigated by varying the inlet concentration of benzene (0.12-0.95g/m(3)), toluene (0.14-1.48g/m(3)) and gas-flow rate (0.024-0.072m(3)/h). At comparable loading rates, benzene removal in the mixture was reduced in the range of 6.6-41% in comparison with the individual benzene degradation. Toluene removal in mixture was even more affected as observed from the reductions in REs, ranging from 18.4% to 76%. The results were statistically interpreted by performing an analysis of variance (ANOVA) to elucidate the main and interaction effects.