Displaying all 2 publications

Abstract:
Sort:
  1. Kherad B, Waliszewski M, Leschke M, Kader MA, Bang LH, Ruiz-Poveda FL, et al.
    J Interv Cardiol, 2018 Jun;31(3):338-344.
    PMID: 29205492 DOI: 10.1111/joic.12472
    OBJECTIVES: To evaluate the 9-month safety and efficacy of polymer-free sirolimus eluting drug eluting stents in septuagenarians and octogenarians.

    METHODS: An all-comer, worldwide single armed trial (ClinicalTrials.gov Identifier NCT02629575) was conducted to demonstrate the safety and efficacy of an ultra-thin strut, polymer-free sirolimus eluting stent (PF-SES). The primary endpoint was the 9-month target revascularization rate (TLR). Secondary endpoints included the rates of major adverse cardiac events (MACE), stent thrombosis (ST) and bleeding (BARC) in septuagenarians (≥70 years, <80 years), and in octogenarians (≥80 years) to be compared to the younger patient group (<70 years).

    RESULTS: A total of 1607 patients were treated with PF-SES in the sub-70-year-old age group, 694 in septuagenarians, and 371 in the octogenarian patient group. At 9 months, the MACE rates were 7.2% in octogenarians, 5.3% in septuagenarians, and 3.0% in the younger patient group (P = 0.001). These were mostly driven by all-cause mortality (4.4% vs 1.9% vs 0.6%, P 

  2. Krackhardt F, Rosli MA, Leschke M, Schneider A, Sperling C, Heang TM, et al.
    Catheter Cardiovasc Interv, 2018 06;91(7):1221-1228.
    PMID: 28944613 DOI: 10.1002/ccd.27306
    OBJECTIVE: The objective of this study was to compare the safety and efficacy of a polymer-free sirolimus coated, ultrathin strut drug eluting stent (PF-SES) to its uncoated bare-metal stent (BMS) platform of identical stent architecture.

    BACKGROUND: Recently published randomized trials comparing BMS to DES with a focus on shortened dual-antiplatelet therapy reported incidences of stent thrombosis (ST) and bleeding complications (LEADERS FREE) in favor of drug eluting stents (DES).

    METHODS: Data of previously published large-sale, international, single-armed, multicenter, observational studies of ultra-thin PF-SES, and BMS were propensity score (PS) matched for selected lesion morphological and cardiovascular risk factors to compare target lesion revascularization (TLR), myocardial infarction, cardiac death, major adverse cardiac events (MACE), bleeding complications and ST rates. Primary endpoint in both studies was TLR at 9 months.

    RESULTS: At 9 months the rates of TLR was significantly lower in the PF-SES group as compared with patients treated with the BMS analogue of identical stent design (1.4% vs. 4.6%, P = 0.005). Likewise the 9-month MACE rates were lower in the PF-SES group (3.2% vs. 8.7%, P = 0.001) whereas there were no differences in the accumulated ST rates (0.5% vs. 1.5%, P = 0.109). Overall accumulated bleeding incidences (BARC 1-5) were not significantly different between PF-SES and BMS patients (1.8% vs. 2.7%, p = 0.388).

    CONCLUSIONS: PF-SES are superior over analogue BMS of identical stent architecture in daily clinical routine with lower rates of TLR and MACE in a PS-matched, unselected patient population without differences in accumulated ST rates and bleeding frequencies given the currently favored postprocedural comedication (ClinicalTrials.gov Identifier NCT02629575).

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links