Displaying all 2 publications

Abstract:
Sort:
  1. Wali HA, Mazlan R, Kei J
    Ear Hear, 2019 2 27;40(5):1233-1241.
    PMID: 30807541 DOI: 10.1097/AUD.0000000000000707
    OBJECTIVES: Wideband absorbance (WBA) is an emerging technology to evaluate the conductive pathway (outer and middle ear) in young infants. While a wealth of research has been devoted to measuring WBA at ambient pressure, few studies have investigated the use of pressurized WBA with this population. The purpose of this study was to investigate the effect of age on WBA measured under pressurized conditions in healthy infants from 0 to 6 months of age.

    DESIGN: Forty-four full-term healthy neonates (17 males and 27 females) participated in a longitudinal study. The neonates were assessed at 1-month intervals from 0 to 6 months of age using high-frequency tympanometry, acoustic stapedial reflex, distortion product otoacoustic emissions, and pressurized WBA. The values of WBA at tympanometric peak pressure (TPP) and 0 daPa across the frequencies from 0.25 to 8 kHz were analyzed as a function of age.

    RESULTS: A linear mixed model analysis, applied to the data, revealed significantly different WBA patterns among the age groups. In general, WBA measured at TPP and 0 daPa decreased at low frequencies (<0.4 kHz) and increased at high frequencies (2 to 5and 8 kHz) with age. Specifically, WBA measured at TPP and 0 daPa in 3- to 6-month-olds was significantly different from that of 0- to 2-month-olds at low (0.25 to 0.31 kHz) and high (2 to 5 and 8 kHz) frequencies. However, there were no significant differences between WBA measured at TPP and 0 daPa for infants from 3 to 6 months of age.

    CONCLUSIONS: The present study provided clear evidence of maturation of the outer and middle ear system in healthy infants from birth to 6 months. Therefore, age-specific normative data of pressurized WBA are warranted.

  2. Wali HA, Mazlan R, Kei J
    J Speech Lang Hear Res, 2017 10 17;60(10):2965-2973.
    PMID: 28975265 DOI: 10.1044/2017_JSLHR-H-17-0120
    Purpose: The present study aimed to establish normative data for wideband absorbance (WBA) measured at tympanometric peak pressure (TPP) and 0 daPa and to assess the test-retest reliability of both measurements in healthy neonates.

    Method: Participants of this cross-sectional study included 99 full-term neonates (165 ears) with mean chronological age of 46.7 hrs (SD = 26.3 hrs). Of the 99 neonates, 58 were Malay, 28 were Indian, and 13 were Chinese. The neonates who passed high-frequency (1 kHz) tympanometry, acoustic stapedial reflex, and distortion product otoacoustic emission screening tests were assessed using a pressurized WBA test (wideband tympanometry). To reduce the number of measurement points, the WBA responses were averaged to 16 one-third octave frequency bands from 0.25 to 8 kHz. A mixed-model analysis of variance was applied to the data to investigate the effects of frequency, ear, gender, and ethnicity on WBA. The analysis of variance was also used to compare between WBA measured at TPP and 0 daPa. An interclass correlation coefficient test was applied at each of the 16 frequency bands to measure the test-retest reliability of WBA at TPP and 0 daPa.

    Results: Both WBA measurements at TPP and 0 daPa exhibited a multipeaked pattern with 2 maxima at 1.25-1.6 kHz and 6.3 kHz and 2 minima at 0.5 and 4 kHz. The mean WBA measured at TPP was significantly higher than that measured at 0 daPa at 0.25, 0.4, 0.5, 1.25, and 1.6 kHz only. A normative data set was developed for absorbance at TPP and at 0 daPa. There was no significant effect of ethnicity, gender, and ear on both measurements of WBA. The test-retest reliability of WBA at TPP and 0 daPa was high with the interclass correlation coefficient ranging from 0.77 to 0.97 across the frequencies.

    Conclusions: Normative data of WBA measured at TPP and 0 daPa for neonates were provided in the present study. Although WBA at TPP was slightly higher than the WBA measured at 0 daPa at some frequencies below 2 kHz, the WBA patterns of the 2 measurements were nearly identical. Moreover, the test-retest reliability of both WBA measurements was high.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links