Displaying all 4 publications

Abstract:
Sort:
  1. Hisham RB, Sabariah AR, Yunus AG
    Med J Malaysia, 2006 Mar;61(1):88-90.
    PMID: 16708740 MyJurnal
    Perianal mucinous adenocarcinoma is a rare tumor which may be associated with long-standing chronic perianal sepsis. Early diagnosis is challenging and is based on a high index of clinical suspicion and specific histological features. Definitive treatment is surgical, in the form of an abdomino-perineal resection. We hereby describe a case of a perianal mucinous adenocarcinoma arising from long-standing recurrent perianal fistula and complement this with a brief review of the literature pertaining in particular to the management of this condition.
  2. Hisham RB, Thuaibah H, Gul YA
    Asian J Surg, 2006 Apr;29(2):95-7.
    PMID: 16644510
    We present the case of a 32-year-old woman who, 10 months after abdominoperineal resection and total mesorectal excision for a locally advanced mucinous adenocarcinoma of the rectum, presented with local recurrence and metastases to the breast, spine, the left eye and orbit. Following surgery, due to the patient's personal reasons, adjuvant chemoradiation was not given. The patient died 2 months later, with disseminated cancer. To the best of our knowledge, breast as well as ocular metastasis in a patient with mucinous adenocarcinoma of the rectum has never been reported and, therefore, needs to be documented.
  3. Gee T, Hisham RB, Jabar MF, Gul YA
    Tech Coloproctol, 2013 Apr;17(2):181-6.
    PMID: 22983551 DOI: 10.1007/s10151-012-0894-6
    Idiopathic chronic anal fissure is believed to be a consequence of a traumatic acute anodermal tear followed by recurrent inflammation and poor healing due to relative tissue ischaemia secondary to internal sphincter spasm. This pilot trial compared the efficacy of a novel manufactured ano-coccygeal support attached to a standard toilet seat (Colorec) to the standard procedure of lateral internal sphincterotomy (LIS) for chronic anal fissure.
  4. Ahmad HAB, El-Badawy IM, Singh OP, Hisham RB, Malarvili MB
    Technol Health Care, 2018;26(4):573-579.
    PMID: 29758955 DOI: 10.3233/THC-171067
    BACKGROUND: Fetal heart rate (FHR) monitoring device is highly demanded to assess the fetus health condition in home environments. Conventional standard devices such as ultrasonography and cardiotocography are expensive, bulky and uncomfortable and consequently not suitable for long-term monitoring. Herein, we report a device that can be used to measure fetal heart rate in clinical and home environments.

    METHODS: The proposed device measures and displays the FHR on a screen liquid crystal display (LCD). The device consists of hardware that comprises condenser microphone sensor, signal conditioning, microcontroller and LCD, and software that involves the algorithm used for processing the conditioned fetal heart signal prior to FHR display. The device's performance is validated based on analysis of variance (ANOVA) test.

    RESULTS: FHR data was recorded from 22 pregnant women during the 17th to 37th week of gestation using the developed device and two standard devices; AngelSounds and Electronic Stethoscope. The results show that F-value (1.5) is less than F𝑐𝑟𝑖𝑡, (3.1) and p-value (p> 0.05). Accordingly, there is no significant difference between the mean readings of the developed and existing devices. Hence, the developed device can be used for monitoring FHR in clinical and home environments.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links