Displaying all 6 publications

Abstract:
Sort:
  1. Hashim SE, Fatisha A, Nazri MN
    MyJurnal
    Subperiosteal haematoma of the orbit is an uncommon complication of maxillofacial trauma, hence easily missed. It usually presents subacutely with proptosis and diplopia. In our case, the subperiosteal haematoma is complicated with high intraocular pressure, necessisating measures to reduce the intraocular pressure. Unresponsive to only medical treatment, surgical evacuation was carried out in this patient. Removal of the clot finally relieved the intraocular pressure and simultaneously improved the proptosis and the cumbersome diplopia.
  2. Hashim SE, Tan HK, Wan-Hazabbah WH, Ibrahim M
    Ann Acad Med Singap, 2008 Nov;37(11):940-6.
    PMID: 19082201
    INTRODUCTION: Refractive error remains one of the primary causes of visual impairment in children worldwide, and the prevalence of refractive error varies widely. The objective of this study was to determine the prevalence of refractive error and study the possible associated factors inducing refractive error among primary school children of Malay ethnicity in the suburban area of Kota Bharu, Kelantan, Malaysia.

    MATERIALS AND METHODS: A school-based cross-sectional study was performed from January to July 2006 by random selection on Standard 1 to Standard 6 students of 10 primary schools in the Kota Bharu district. Visual acuity assessment was measured using logMAR ETDRS chart. Positive predictive value of uncorrected visual acuity equal or worse than 20/40, was used as a cut-off point for further evaluation by automated refraction and retinoscopic refraction.

    RESULTS: A total of 840 students were enumerated but only 705 were examined. The prevalence of uncorrected visual impairment was seen in 54 (7.7%) children. The main cause of the uncorrected visual impairment was refractive error which contributed to 90.7% of the total, and with 7.0% prevalence for the studied population. Myopia is the most common type of refractive error among children aged 6 to 12 years with prevalence of 5.4%, followed by hyperopia at 1.0% and astigmatism at 0.6%. A significant positive correlation was noted between myopia development with increasing age (P <0.005), more hours spent on reading books (P <0.005) and background history of siblings with glasses (P <0.005) and whose parents are of higher educational level (P <0.005). Malays in suburban Kelantan (5.4%) have the lowest prevalence of myopia compared with Malays in the metropolitan cities of Kuala Lumpur (9.2%) and Singapore (22.1%).

    CONCLUSION: The ethnicity-specific prevalence rate of myopia was the lowest among Malays in Kota Bharu, followed by Kuala Lumpur, and is the highest among Singaporean Malays. Better socio-economic factors could have contributed to higher myopia rates in the cities, since the genetic background of these ethnic Malays are similar.

  3. Hashim SE, Sirat HM, Yen KH, Ismail IS, Matsuki SN
    Nat Prod Commun, 2015 Sep;10(9):1561-3.
    PMID: 26594759
    Seven compounds were isolated from the n-hexane and chloroform extracts of the flowers and leaves of four Hornstedtia species and their structures were identified using spectroscopic techniques as 3,7,4'-trimethylkaempferol (1), 3,7-dimethylkaempferol (2), 7,4'-dimethylkaempferol (3), 3,5-dimethylkaempferol (4), 3-methylkaempferol (5), stigmast-4-en-3-one (6), and 6-hydroxy-stigmast-4-en-3-one (7). Compounds 1 to 7 were isolated from these species for the first time. They were assayed for free radical scavenging and α-glucosidase inhibition activities. The DPPH assay showed that 3-methylkaempferol (5) was the most potent antioxidant agent with an IC50 value 78.6 µM, followed by 7,4'-dimethylkaempferol (3) (IC50 = 86.1 µM). For α-glucosidase inhibition activity, 3-methylkaempferol (5) exhibited significant inhibitory activity with an IC50 value 21.0 µM. The present study revealed that Hornstedtia species have potential activities as antioxidant and α-glucosidase inhibitors.
  4. Siti Nor Aishah AR, Mutalib A, Asma H, Baig AA, Naing NN, Hashim SE, et al.
    Med J Malaysia, 2020 11;75(6):685-690.
    PMID: 33219178
    OBJECTIVES: To design and develop a simple vision test algorithm for mobile application and perform a pilot study to determine its validity and reliability as a tool for vision test in the community.

    METHODS: A simple visual acuity test algorithm in the form of a single letter E display was designed as the optotype for development of a mobile application. The standardised optotype is presented at random to test visual acuity for corresponding level of 3/60, 6/60, 6/18, and 6/12. The final result is auto-generated based on the classification of the WHO for visual impairment and blindness. The Snellen chart was used as the gold standard to determine its validity while five different users were involved to determine its inter-rater reliability. A pilot study was performed between April till November 2019, in the Universiti Sultan Zainal Abidin Medical Centre (UMC) at Kuala Nerus and Mooris Optometrist Centre at Marang, Terengganu. A total of 279 participants aged four years old and above were involved in this study.

    RESULTS: The highest sensitivity was found at the vision level cut-off point of 6/12 with the percentage of 92.7% and 86.8% for the right and left eye, respectively. The specificity was more than 89% for all vision levels in both eyes. The Krippendorff's alpha value for the inter-rater reliability was 0.87 and 0.83.

    CONCLUSION: The relatively high level of validity and reliability obtained indicate the feasibility of using the designed optotype to develop a valid and reliable mobile app for vision test. The app can be used to screen vision by nonmedical persons, at anytime and anywhere to help improve public awareness and capability to correctly determine their visual status.

  5. Ozir MA, Nordin MH, Hashim SE, Adzahar S, Ahmad MA, Ng KS, et al.
    Cureus, 2024 Oct;16(10):e71210.
    PMID: 39525159 DOI: 10.7759/cureus.71210
    Leber hereditary optic neuropathy (LHON) is a rare maternally inherited mitochondrial disorder that predominantly affects young men, leading to optic nerve degeneration and subsequent vision loss. The rarity of LHON and its clinical similarity to optic neuritis complicates diagnosis, necessitating genetic testing to confirm specific point mutations and predict visual outcomes. We report a rare case of an 18-year-old Malay male with m.14484T>C/MT-ND6 mutation of LHON, who demonstrated remarkable spontaneous visual recovery over a three-year follow-up period. This report highlights the pivotal role of genetic testing in diagnosing LHON, explores the variability in visual outcomes associated with different mutations, and underscores the potential for spontaneous recovery in specific mutation variants. Early diagnosis, genetic counseling, and supportive management are critical for optimizing outcomes and improving quality of life.
  6. Abdul Rahman SNA, Naing NN, Othman AM, Mohamad Z, Ibrahim TMM, Hashim SE, et al.
    Medicina (Kaunas), 2023 May 10;59(5).
    PMID: 37241144 DOI: 10.3390/medicina59050912
    Background and Objectives: The health-related mobile applications (app) might assist in promoting inclusive health and tele-treatment, especially for the less severe diseases. In this paper, a study had been done to determine the app's reliability in terms of raters and the app's agreement with the Snellen chart. Materials and Methods: A cross-sectional sectional study was conducted between November 2019 and September 2020. Participants were selected via purposive sampling from selected communities in Terengganu state. All participants underwent vision testing with the Vis-Screen app and Snellen chart for validity and reliability accordingly. Results: A total of 408 participants were involved, with a mean age of 29.3. The sensitivity of the presenting vision of the right eye (PVR) ranged from 55.6% to 88.4%, with specificity between 94.7% to 99.3%, while the positive and negative predictive values were between 57.9% and 81.7% and 96.8% and 99.0%, respectively. The positive likelihood ratios ranged between 16.73 and 73.89, whereas the negative likelihood ratios ranged from 0.12 to 0.45. The area under the receiver operating characteristic curve (AUC) for all cut-off points ranged between 0.93 and 0.97, and the optimum cut-off point was at 6/12. The kappa values for intra-rater and inter-rater were 0.85 and 0.75, respectively, while the app's reliability with the Snellen chart was 0.61. Conclusions: Vis-Screen was concluded to be valid and reliable for use as a screening tool for detecting individuals with visual impairment and blindness in the community. A valid and reliable portable vision screener like Vis-Screen will help expand the eye care feasibility while providing similar accuracy as the conventional charts in clinical practices.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links