Displaying all 4 publications

Abstract:
Sort:
  1. Giok KC, Veettil SK, Menon RK
    J Prosthet Dent, 2023 Oct 10.
    PMID: 37827970 DOI: 10.1016/j.prosdent.2023.08.022
    STATEMENT OF PROBLEM: Different varieties of fiber and metal intraradicular posts have been used for the restoration of endodontically treated teeth with insufficient sound tooth structure. Evidence on the comparative efficacy of posts in a clinical setting is insufficient to provide clear clinical guidelines and recommendations.

    PURPOSE: The purpose of this systematic review with network meta-analysis was to assess the comparative efficacy of fiber and metal posts used for the restoration of endodontically treated teeth.

    MATERIAL AND METHODS: A search was conducted for trials published in Medline, Scopus, PubMed, and Cochrane Central Register of Controlled Trials from inception until November 2022. The study was registered with the International Prospective Register of Systematic Reviews (PROSPERO) (CRD42022384340). A network meta-analysis was performed on data from randomized controlled trials that assessed the comparative efficacy of fiber posts and metal posts for the restoration of endodontically treated teeth. Subgroup analyses were performed to compare all the varieties of fiber and metal posts. The types of posts were ranked according to their efficacy using the Surface Under the Cumulative Ranking (SUCRA) system. The Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) approach was used to assess the level of certainty of evidence.

    RESULTS: Twenty-five articles were included in the quantitative analysis. Fiber posts (RR=0.15 [95% CI: 0.06, 0.33]) significantly prevented tooth fracture as compared with no posts. Prefabricated carbon fiber posts (RR=0.06 [95% CI: 0, 0.54]) ranked highest followed by custom glass fiber posts (RR=0.15 [95% CI: 0.04, 0.52]) and prefabricated glass fiber posts (RR=0.22 [95% CI: 0.07, 0.62]) in the outcome of tooth fracture. Metal posts (RR=0.24 [95% CI: 0.12, 0.46]) ranked higher than fiber posts (RR=0.39 [95% CI: 0.27, 0.56]) in the outcome of debonding. Custom gold alloy posts (RR=0.12 [95% CI: 0.03, 0.48]), prefabricated gold alloy posts (RR=0.04 [95% CI: 0.00, 0.87]), and prefabricated titanium posts (RR=0.21 [95% CI: 0.10, 0.45]) had higher rankings in the outcome of debonding or loss of retention of a post followed by custom glass fiber posts (RR=0.37 [95% CI: 0.21, 0.63]) and prefabricated glass fiber posts (RR=0.38 [95%CI: 0.25, 0.58]). Prefabricated glass fiber posts (RR=0.40 [95% CI: 0.20, 0.81]) had statistically significant differences in the outcome of secondary caries. The GRADE approach determined a moderate level of certainty of evidence.

    CONCLUSIONS: The use of a fiber post when indicated results in reduced risk of tooth fracture as compared with no post. Prefabricated carbon fiber posts, prefabricated glass fiber posts, and custom glass fiber posts reveal a lower risk of tooth fracture. Overall, the use of prefabricated glass fiber posts had a lower risk of tooth fracture, debonding, and secondary caries. However, more trials with longer follow-up periods are recommended to enhance the certainty of evidence.

  2. Giok KC, Veettil SK, Menon RK
    Clin Oral Investig, 2024 Jan 06;28(1):78.
    PMID: 38183500 DOI: 10.1007/s00784-023-05467-4
    OBJECTIVES: The purpose of this systematic review with network meta-analysis was to assess the comparative efficacy of various types of denture adhesives in complete denture patients.

    MATERIAL AND METHODS: A search was conducted for trials published in Scopus, PubMed, and Cochrane Central Register of Controlled Trials from inception until July 2023 (PROSPERO: CRD42023451045). A network meta-analysis was performed to assess the comparative efficacy of different denture adhesive types and ranked using the Surface Under the Cumulative Ranking (SUCRA) system. The Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) approach was used to assess the level of certainty of evidence.

    RESULTS: Seventeen articles were included in the quantitative analysis. Cream denture adhesives significantly increased bite force in both incisal region (RR = 7.63[95%CI: 3.34, 11.91]) (P 

  3. Giok KC, Veettil SK, Menon RK
    J Dent, 2024 Jul;146:105065.
    PMID: 38762079 DOI: 10.1016/j.jdent.2024.105065
    OBJECTIVES: To perform a comprehensive quantitative and qualitative analysis of the findings from previously published meta-analyses and to assess existing biases.

    DATA/SOURCES: A search was conducted for meta-analyses of observational studies investigating the association between any risk factor and peri‑implantitis in PubMed, Scopus, Cochrane Database of Systematic Reviews, and Epistemonikos, from inception until October 2023 (PROSPERO: CRD42024512408).

    STUDY SELECTION: From a total of 5002 publications, 51 full-text articles were evaluated for eligibility, and 12 articles that described 41 unique meta-analyses evaluating the association between risk factors and periimplantitis were selected. Among 41 associations, 24 associations were significant. None of the associations were graded as convincing evidence. Two associations, presence of periodontitis (OR = 3.84 [95 % CI 2.58,5.72]) and cigarette smoking (RR=2.07 [95 % CI 1.41,3.04]) were graded as highly suggestive. Eight associations, diabetes mellitus, hyperglycaemia, lack of prophylaxis, history of chronic periodontal disease, ongoing or history of periodontal disease, implants located in the anterior region of the jaw (maxillary and mandibular), osteoprotegerin (OPG) gene polymorphisms, and lack of keratinized mucosal width were graded as suggestive evidence.

    CONCLUSIONS: Periodontitis and cigarette smoking are highly suggestive risk factors for peri‑implantitis. The remaining risk factors which are suggestive require more high-quality studies to be performed to upgrade the level of evidence.

    CLINICAL SIGNIFICANCE: The highly suggestive and suggestive risk factors for peri‑implantitis summarized in this umbrella review should be rigorously assessed, monitored and managed by clinicians to reduce the risk peri‑implantitis, as well as to form part of the preoperative consent process.

  4. Giok KC, Veettil SK, Menon RK
    J Prosthet Dent, 2024 Apr 16.
    PMID: 38632026 DOI: 10.1016/j.prosdent.2024.03.024
    STATEMENT OF PROBLEM: Extensive research has been carried out on the various aspects of diagnosing and treating peri-implantitis. However, clinical guidelines for the management of peri-implantitis based on high quality evidence are lacking.

    PURPOSE: The purpose of this systematic review with network meta-analysis was to analyze the current evidence on nonsurgical and surgical interventions for the treatment of peri-implantitis and synthesize clinical guidelines based on high quality evidence.

    MATERIAL AND METHODS: A search was conducted for trials published in Medline, Scopus, PubMed, and Cochrane Central Register of Controlled Trials from inception until July 2023. The study was registered with the International Prospective Register of Systematic Reviews (PROSPERO) (CRD42023451056). A network meta-analysis was performed on data from randomized controlled trials that assessed nonsurgical and surgical interventions for the treatment of peri-implantitis. The interventions were ranked according to their efficacy using surface under the cumulative ranking (SUCRA) system. The grading of recommendations, assessment, development, and evaluations (GRADE) approach was used to assess the level of certainty of evidence.

    RESULTS: A total of 45 articles were included in the quantitative analysis. The GRADE approach determined a moderate to high level of certainty of evidence. Among the nonsurgical interventions, mechanical debridement with adjunctive systemic antibiotics was significant in improving probing depth at 3 months and beyond 6 months, clinical attachment loss at 3 months, and clinical attachment loss beyond 6 months. Mechanical debridement with adjunctive topical antibiotics was significant in improving probing depth beyond 6 months, clinical attachment loss at 3 months, clinical attachment loss beyond 6 months, and radiographic bone loss beyond 6 months. Mechanical debridement with adjunctive photodynamic therapy was significant in improving probing depth beyond 6 months, clinical attachment loss at 3 months, clinical attachment loss beyond 6 months, and radiographic bone loss beyond 6 months. Mechanical debridement with adjunctive systemic antibiotics and photodynamic therapy was significant in improving probing depth beyond 6 months. Among surgical interventions, open flap debridement with implant surface decontamination and open flap debridement with decontamination and adjunctive photodynamic therapy were significant in improving probing depth at 3 months.

    CONCLUSIONS: Mechanical debridement with adjunctive systemic antibiotics or photodynamic therapy results in improved clinical outcomes.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links