Displaying all 9 publications

Abstract:
Sort:
  1. Yoshida N, Naito Y, Yasuda R, Murakami T, Ogiso K, Hirose R, et al.
    Endosc Int Open, 2017 12;5(12):C6.
    PMID: 29620079 DOI: 10.1055/a-0587-5955
    [This corrects the article DOI: 10.1055/s-0043-120659.].
  2. Yoshida N, Inoue K, Yasuda R, Hirose R, Dohi O, Naito Y, et al.
    Dig Dis Sci, 2018 12;63(12):3457-3464.
    PMID: 30232637 DOI: 10.1007/s10620-018-5275-1
    INTRODUCTION: Previous narrow-band imaging (NBI) was dark and reported not to be useful for polyp detection. In this study, we analyzed the efficacy of an additional 30-s observation of the right-sided colon with the recent bright high-resolution NBI.

    METHODS: We enrolled patients undergoing colonoscopy from February 2015 to May 2017 in two institutions. All procedures were performed with the latest system (EVIS LUCERA ELITE, Olympus). The cecum and ascending colon were first observed with white light imaging (WLI) in both the NBI and WLI group. Then, the colonoscope was re-inserted, and the cecum and ascending colon were observed for an additional 30 s. In this second observation, NBI was performed for the first 130 patients in the NBI group and WLI for the next 130 in the WLI group. The number of adenoma and sessile serrated polyps (ASPs) in the second observation were examined in both groups. According to our initial pilot study, the sample size was estimated at 126.

    RESULTS: In the first observation, the number of ASPs was 72 in the NBI group and 72 in the WLI group (p = 1.0). In the second observation, the number of ASPs was 23 in the NBI group and 10 in the WLI group (p = 0.02). The polyp and adenoma detection rates in the second observation were 16.2% and 12.3% in the NBI group and 7.7% (p = 0.03) and 6.2% (p = 0.09) in the WLI group.

    CONCLUSIONS: The additional 30-s observation with recent NBI decreased missed polyps in the right-sided colon.

  3. Yoshida N, Hirose R, Watanabe M, Yamazaki M, Hashimoto S, Matsubara S, et al.
    JGH Open, 2021 Jan;5(1):160-162.
    PMID: 33490630 DOI: 10.1002/jgh3.12435
    COVID-19 rarely causes lower gastrointestinal bleeding even though its RNA has been detected in patient's stool. Urgent colonoscopy in a COVID-19 patient with massive bloody stool requires various procedural and equipment considerations. Here, we present a case of colonoscopic hemostasis of a cecal hemorrhagic ulceration in a patient on heparin for COVID-19 coagulopathy. We also share various management methods for the prevention of COVID-19 contamination. A 71-year-old man was diagnosed with COVID-19 pneumonia and subsequently underwent hemodiafiltration. Heparin was initiated for COVID-19 coagulopathy. At day 42, the patient experienced 2000 mL of bloody stool. An operator performed urgent colonoscopy with three assistants in a negative-pressure room with full personal protective equipment. A hemorrhagic ulceration was detected at the cecum, and endoscopic hemostasis was performed. Immunohistochemistry was positive for cytomegalovirus. Postprocedure, the endoscopic systems were thoroughly cleaned, and specific measures for endoscope reprocessing and disinfection were performed to prevent contamination with COVID-19.
  4. Yoshida N, Naito Y, Yasuda R, Murakami T, Hirose R, Ogiso K, et al.
    Int J Colorectal Dis, 2017 Sep;32(9):1253-1260.
    PMID: 28725959 DOI: 10.1007/s00384-017-2855-z
    PURPOSE: Linked color imaging (LCI) by laser endoscopy is a novel narrow band light observation. In this study, we analyzed the efficacy of LCI for improving the various featured colorectal polyp's visibility utilizing a subjective endoscopist's visibility scoring and objective color difference (CD) value.

    METHODS: We retrospectively reviewed two pictures both with white light (WL) and LCI for 54 consecutive neoplastic polyps 2-20 mm in size. All pictures were evaluated by four endoscopists according to a published polyp visibility score from four (excellent visibility) to one (poor visibility). Additionally, we calculated CD value between each polyp and surrounding mucosa in LCI and WL using an original software.

    RESULTS: The mean polyp visibility scores of LCI (3.11 ± 1.05) were significantly higher than those of WL (2.50 ± 1.09, P 

  5. Yoshida N, Dohi O, Inoue K, Yasuda R, Murakami T, Hirose R, et al.
    Gut Liver, 2019 03 15;13(2):140-148.
    PMID: 30513568 DOI: 10.5009/gnl18276
    A laser endoscopy system was developed in 2012. The system allows blue laser imaging (BLI), BLI-bright, and linked color imaging (LCI) to be performed as modes of narrow-band light observation; these modes have been reported to be useful for tumor detection and characterization. Furthermore, an innovative endoscopy system using four-light emitting diode (LED) multilight technology was released in 2016 to 2017 in some areas in which laser endoscopes have not been approved for use, including the United States and Europe. This system enables blue light imaging (this is also known as BLI) and LCI with an LED light source instead of a laser light source. Several reports have shown that these modes have improved tumor detection. In this paper, we review the efficacy of BLI and LCI with laser and LED endoscopes in tumor detection and characterization.
  6. Yoshida N, Fukumoto K, Hasegawa D, Inagaki Y, Inoue K, Hirose R, et al.
    J Gastroenterol Hepatol, 2021 Dec;36(12):3337-3344.
    PMID: 34260116 DOI: 10.1111/jgh.15625
    BACKGROUND AND AIM: High-grade dysplasia (HGD) and T1 lesions are accidentally resected by cold snare polypectomy (CSP) and the characteristics, and follow-up of them has not been reported. In this study, we analyzed the histopathological findings and recurrence of them.

    METHODS: This was a multicenter retrospective-cohort study. We collected HGD and T1 lesions of ≤ 10 mm resected by CSP among 15 520 patients receiving CSP from 2014 to 2019 at nine related institutions, and we extracted only cases receiving definite follow-up colonoscopy after CSP of HGD and T1 lesions. We analyzed these tumor's characteristics and therapeutic results such as R0 resection and local recurrence and risk factors of recurrence.

    RESULTS: We collected 103 patients (0.63%) and extracted 80 lesions in 74 patients receiving follow-up colonoscopy for CSP scar. Mean age was 68.4 ± 12.0, and male rate was 68.9% (51/80). The mean tumor size (mm) was 6.6 ± 2.5, and the rate of polypoid morphology and rectum location was 77.5% and 25.0%. The rate of magnified observation was 53.8%. The rates of en bloc resection and R0 resection were 92.5% and 37.5%. The local recurrence rate was 6.3% (5/80, median follow-up period: 24.0 months). The recurrence developed within 3 months after CSP for four out of five recurrent cases. Comparing five recurrent lesions to 75 non-recurrent lesions, a positive horizontal margin was a significant risk factor (60.0% vs 10.7%, P 

  7. Yoshida N, Naito Y, Yasuda R, Murakami T, Ogiso K, Hirose R, et al.
    Endosc Int Open, 2017 Dec;5(12):E1235-E1241.
    PMID: 29218315 DOI: 10.1055/s-0043-120659
    Background and study aims:  Water drop adhesions (WDA) impair endoscopic view during gastrointestinal endoscopy. We developed a novel lens cleaner designed using two types of harmLess surfactants and it is reported to be useful for preventing lens cloudiness during colorectal ESD. In the current study, we examined the ability of it for preventing and removing WDA.

    Patients and methods:  During laboratory experiments, the cleaner (Cleash; Fujifilm Co., Tokyo, Japan and Nagase Medicals Co., Hyogo, Japan) was applied to the endoscopic lens and an air/water device (AWD) (water 200 mL, dimethicone 1 mL, Cleash 1 mL). The endoscope was submerged in water 100 times for 5 cycles. Rates of WDA were calculated for various groups (lens and AWD with or without Cleash) and compared to a normal cleaner (SL cleaner). During clinical research, 30 colonoscopies and 30 esophagogastroduodenoscopies were analyzed. For the Cleash group, the cleaner was applied to both lens and AWD. The numbers of WDA and WDA with non-rapid removal were calculated, compared to those of the SL cleaner group.

    Results:  The mean WDA rate for the Cleash setting (lens: Cleash; AWD: Cleash) was 11.0 %, which was significantly lower than other settings (lens: SL cleaner; AWD: water, 31.0 %;P 

  8. Tomie A, Yoshida N, Kugai M, Hirose R, Dohi O, Inoue K, et al.
    Gastroenterol Res Pract, 2020;2020:9656040.
    PMID: 32411210 DOI: 10.1155/2020/9656040
    Materials and Methods: This was a multicenter retrospective cohort study. The subjects were patients aged ≥20 years treated for chronic constipation from May 2018 to November 2019 at 12 related institutions. Patients were divided into ≤74 years and ≥75 years old. Elobixibat at 10 mg/day was prescribed for two weeks. We then analyzed the discontinuation due to ineffectiveness, change of spontaneous bowel movements (SBM), stool consistency, the time until the first SBM, adverse events, and effect-related factors.

    Results: There were 140 cases (61 males) evaluated, with an average age of 72.1 ± 13.6 years (≤74 years: 71 cases; ≥75 years: 69 cases). The discontinuation rate was 7.9%. The SBM (times/week) increased from 2.86 to 6.08 (p < 0.001). The overall SBM improvement rate was 74.0% (≤74 years: 78.2% vs. ≥75 years: 68.9%, p = 0.31; male: 75.0% vs. female: 73.3%, p = 0.78). The overall improvement rate of stool consistency was 59.6% (≤74 years: 62.9%, ≥75 years: 56.1%, p = 0.42). The time until the first SBM (hours) for those ≤74 years and ≥75 years was 17.2 ± 14.3 and 11.2 ± 8.4 (p = 0.04). Adverse event rates for those ≤74 years and ≥75 years were 28.2% and 10.1% (p < 0.01). There were no significant effect-related factors for gender, age, and use of laxatives.

    Conclusions: Short-period elobixibat is shown to be effective also for the elderly and male.

  9. Yoshida N, Draganov PV, John S, Neumann H, Rani RA, Hsu WH, et al.
    Dig Dis Sci, 2023 Oct;68(10):3943-3952.
    PMID: 37558800 DOI: 10.1007/s10620-023-08057-2
    INTRODUCTION: In light-emitting diode (LED) and LASER colonoscopy, linked color imaging (LCI) and blue light/laser imaging (BLI) are used for lesion detection and characterization worldwide. We analyzed the difference of LCI and BLI images of colorectal lesions between LED and LASER in a multinational study.

    METHODS: We prospectively observed lesions with white light imaging (WLI), LCI, and BLI using both LED and LASER colonoscopies from January 2020 to August 2021. Images were graded by 27 endoscopists from nine countries using the polyp visibility score: 4 (excellent), 3 (good), 2 (fair), and 1 (poor) and the comparison score (LED better/similar/LASER better) for WLI/LCI/BLI images of each lesion.

    RESULTS: Finally, 32 lesions (polyp size: 20.0 ± 15.2 mm) including 9 serrated lesions, 13 adenomas, and 10 T1 cancers were evaluated. The polyp visibility scores of LCI/WLI for international and Japan-expert endoscopists were 3.17 ± 0.73/3.17 ± 0.79 (p = 0.92) and 3.34 ± 0.78/2.84 ± 1.22 (p 

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links