OBJECTIVES: The first objective was to characterize the analytic performance of the meter for measuring BHBb and BHBp in dairy cattle. The second objective was to characterize the influence of HCT and sample temperature on BHBp concentration measured by the meter.
METHODS: Blood and plasma samples were obtained from 106 periparturient Holstein cattle and 15 lactating Holstein cows with experimentally induced electrolyte and acid-base imbalances. Meter performance was evaluated using Deming regression and Bland-Altman plots. Multivariable linear regression was used to determine the effect of HCT and sample temperature on BHBb and BHBp concentration, respectively.
RESULTS: The meter was linear up to BHB = 3.0 mmol/L as measured by the reference method, equivalent to meter values for BHBb > 4.5 mmol/L and BHBp > 5.2 mmol/L. An increase in HCT resulted in higher BHBb concentration. This result was partially explained by BHBe being much lower than BHBp. Changes in sample temperature caused a linear change in measured BHBp whenever BHBp > 3.0 mmol/L.
CONCLUSIONS: Meter accuracy was markedly dependent on the BHBe-to-BHBp ratio and consequently the HCT. Therefore, the algorithm used by the meter should be revised when applied to bovine blood for improved accuracy.
OBJECTIVES: To evaluate the relationship between plasma [FRA] and glucose concentration ([gluc]) as well as indices of energy balance during early lactation in dairy cattle, and to characterize the influence of plasma total protein concentration ([TP]) and albumin concentration ([albumin]) on [FRA].
ANIMALS: Convenience sample comprising 103 periparturient Holstein-Friesian cattle.
METHODS: Plasma [gluc], [TP], [albumin], and other clinicopathologic indices of energy status were determined periodically from Day 4 postpartum. Body condition score (BCS) was assessed, and backfat thickness (BFT) and longissimus dorsi muscle thickness (LDT) were measured ultrasonographically. Plasma [FRA] was measured at approximately 28 days postpartum. Associations between plasma [FRA] and study variables were evaluated using Spearman's rho and stepwise forward linear regression. Statistical significance was declared at P