A simple and sensitive method for the determination of bisphenol A and its analogues at the ng/mL level in bottled tea beverages is presented. This method utilized a dynamic pH junction to focus the analyte into a more concentrated zone, based on the electrophoretic mobility difference of analytes in the sample matrix and background electrolytes in capillary electrophoresis coupled to mass spectrometry (CE-MS). The optimised analyte focusing led to enhanced signal detection with average peak heights for five bisphenols of 53-170 folds higher than conventional injections. Under optimised conditions, the method showed good linearity in the range of 0.1-100 ng/mL, excellent limits of detection (0.03-0.04 ng/mL), good analyte recovery (80.3-118.1%) with acceptable relative standard deviations (<12%). The limits of quantifications were below the maximum permissible content of bisphenol A set by the European Commission for this product. This method was used to quantitatively analyse bisphenols in six different kinds of bottled tea beverages, making it a promising tool for practical applications.
Enantioselective analysis is critically important in the pharmaceutical and agricultural industries. However, most of the methods reported were developed for the analysis of pure racemates acquired from chemical synthesis or purification. Direct analysis of chiral enantiomers in complex matrices has rarely been reported. This work demonstrated capillary electrophoresis-mass spectrometry (CE-MS) for the enantioselective analysis of botanical drugs for the first time, using a widely used botanical drug, Corydalis Rhizoma, as an example. The method was used for the simultaneous enantioselective analysis of dl-tetrahydropalmatine and (RS)-tetrahydroberberine (canadine) in Corydalis Rhizoma extract. Using (2-hydroxypropyl)-β-cyclodextrin as the chiral selector, a partial filling technique was used to avoid signal suppression and contamination of the MS detector. Post column organic modifier was used to assist with ionization in the flow through microvial CE-MS interface, therefore, organic solvents was not used in the background electrolyte. The completely aqueous background electrolyte contributed to better chiral separations. The CE-MS method established here can directly determine the analytes in their complex matrix without any pre-purification steps, while also offering high sensitivity and low operational costs (including sample, chiral selector and solvent). In the method validation process, good linearity (r > 0.993), sensitivity and accuracy (recoveries within 89.1-110.0%) were demonstrated. The CE-MS technique was shown to be able to provide good selectivity for the simultaneous chiral separation of multiple pairs of enantiomers in complex matrices.
A dynamic pH junction was used in capillary electrophoresis (CE-DAD) to on-line preconcentrate, separate, and determine trace amounts of sulfonamide antibiotics (SAs) in milk and yoghurt samples in this study. A sample matrix with 0.15% acetic acid and 10% methanol (MeOH) at a pH of 4.0, and a background electrolyte (BGE) that contained 35 mM sodium citrate with 10% MeOH at a pH of 8.5, and an acidic barrage of 0.4% acetic acid with 10% MeOH at a pH of 2.5 were utilised to achieve a stacking effect for SAs through a dynamic pH junction. Under optimised conditions, the proposed preconcentration method showed good linearity (30-500 ng/mL, r2 ≥ 0.9940), low limits of detection (LODs) of 4.1-6.3 ng/mL, and acceptable analytes recovery (81.2-106.9%) with relative standard deviations (RSDs) within 5.3-13.7 (n = 9). The limits of quantification (LOQs) were below the maximum residue limit approved by the European Union (EU) in this type of matrices. Sensitivity enhancement factors of up to 129 were reached with the optimised dynamic pH junction using CE with a diode array detector (DAD). The method was used to determine SAs in fresh milk, low-fat milk, full-cream milk, and yoghurt samples.