  1. Thang LY, Breadmore MC, See HH
    J Chromatogr A, 2016 Jul 27.
    PMID: 27485148 DOI: 10.1016/j.chroma.2016.07.067
    An online preconcentration method, namely electrokinetic supercharging (EKS), was evaluated for the determination of tamoxifen and its metabolites in human plasma in nonaqueous capillary electrophoresis with ultraviolet detection (NACE-UV). This method was comprehensively optimized in terms of the leading electrolyte (LE) and terminating electrolyte (TE) injection lengths, as well as electrokinetic sample injection time. The optimized EKS conditions employed were as follows: hydrodynamic injection (HI) of 10mM potassium chloride as LE at 150mbar for 36s (4% of total capillary volume). The sample was injected at 10kV for 300s, followed by HI of 10mM pimozide as TE at 150mbar for 36s (4% of total capillary volume). Separation was performed in 7.5mM deoxycholic acid sodium salt, 15mM acetic acid and 1mM 18-crown-6 in 100% methanol at +25kV with UV detection at 205nm. Under optimized conditions, the sensitivity was enhanced between 160- and 600-fold when compared with our previously developed method based on HI at 150mbar for 12s. The detection limit of the method for tamoxifen and its metabolites were 0.05-0.25ng/mL, with RSDs between 2.1% and 3.5%. Recoveries in spiked human plasma were 95.6%-99.7%. A comparison was also made between the proposed EKS approach and the standard field-amplified sample injection (FASI) technique. EKS proved to be 3-5 times more sensitive than the FASI. The new EKS method was applied to the analysis of tamoxifen and its metabolites in plasma samples from breast cancer patients after liquid-liquid extraction.
  2. Tey HY, Breadmore MC, See HH
    Anal Chem, 2023 Jan 31;95(4):2134-2139.
    PMID: 36649064 DOI: 10.1021/acs.analchem.2c02937
    A polymer inclusion membrane (PIM) based sampling probe was developed for electrokinetic extraction of drugs from biological fluids. The probe was fabricated by dip-coating a nonconductive glass capillary tube in a homogeneous PIM solution for three cycles. The PIM solution comprised cellulose triacetate (CTA), 2-nitrophenyl octyl ether (NPOE), and 1-ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide [EMIM][NTf2] in a ratio of 5:4:2. The developed probe electrokinetically extracted doxorubicin from human plasma, human serum, and dried blood spot (DBS). The practicability and reliability of the electrokinetic extraction were evaluated by LC-MS/MS to quantify the desorption of extracted doxorubicin. Under the optimized conditions, a quantification limit of 0.2-2 ng/mL was achieved for the three biological samples. The probe was further integrated into a portable battery-powered device for safe low-voltage (36 V) electrokinetic extraction. The developed technique is envisioned to provide a more efficient analytical workflow in the laboratory.
  3. Tay KSJ, Breadmore MC, Soh ES, See HH
    J Chromatogr A, 2022 Dec 06;1685:463605.
    PMID: 36375217 DOI: 10.1016/j.chroma.2022.463605
    A new dispersive inclusion complex microextraction (DICM) approach coupled with ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) for the determination of n-nitrosamine impurities in different medicinal products is demonstrated for the first time. The proposed DICM procedures consist of a dispersive liquid phase microextraction steps employing cyclodextrin as an inclusion complex agent to extract n-nitrosamines namely N-nitrosodimethylamine (NDMA), N-nitrosodiethylamine (NDEA), N-nitrosodiisopropylamine (NDIPA), N-ethyl-N-nitrosoisopropylamine (NEIPA) and N-nitroso-di-n-butylamine (NDBA) present in the medicinal products. The sample solutions were prepared by mixing 5% (m/v) NaCl solution with 1.5 mM β-cyclodextrin and 20 mM sodium dodecyl sulphate to form a stable inclusion complex and subsequently extracted into dichloromethane as an extraction solvent. The enriched solution was reconstituted into aqueous solution prior to UPLC-MS/MS analysis. The method showed good linearity in the range of 0.036-1 ng/mL with a correlation coefficient of at least 0.995, acceptable reproducibility (RSD 0.5-5.8%, n=5), low limits of detection (0.011-0.018 ng/mL), and satisfactory relative recoveries (96-105%). The results obtained were found to be at least 10-fold more sensitive comparable to those obtained using validated direct sample dissolutions coupled with UPLC-MS/MS approach.
  4. Abdul Keyon AS, Guijt RM, Bolch CJ, Breadmore MC
    J Chromatogr A, 2014 Oct 17;1364:295-302.
    PMID: 25223612 DOI: 10.1016/j.chroma.2014.08.074
    The accumulation of paralytic shellfish toxins (PSTs) in contaminated shellfish is a serious health risk making early detection important to improve shellfish safety and biotoxin management. Capillary electrophoresis (CE) has been proven as a high resolution separation technique compatible with miniaturization, making it an attractive choice in the development of portable instrumentation for early, on-site detection of PSTs. In this work, capillary zone electrophoresis (CZE) with capacitively coupled contactless conductivity detector (C(4)D) and UV detection were examined with counter-flow transient isotachophoresis (tITP) to improve the sensitivity and deal with the high conductivity sample matrix. The high sodium concentration in the sample was used as the leading ion while l-alanine was used as the terminating electrolyte (TE) and background electrolyte (BGE) in which the toxins were separated. Careful optimization of the injected sample volume and duration of the counter-flow resulted in limit of detections (LODs) ranging from 74.2 to 1020 ng/mL for tITP-CZE-C(4)D and 141 to 461 ng/mL for tITP-CZE-UV, an 8-97 fold reduction compared to conventional CZE. The LODs were adequate for the analysis of PSTs in shellfish samples close to the regulatory limit. Intra-day and inter-day repeatability values (percentage relative standard deviation, n=3) of tITP-CZE-C(4)D and tITP-CZE-UV methods for both migration time and peak height were in the range of 0.82-11% and 0.76-10%, respectively. The developed method was applied to the analysis of a contaminated mussel sample and validated against an Association of Official Analytical Chemists (AOAC)-approved method for PSTs analysis by high performance liquid chromatography (HPLC) with fluorescence detection (FLD) after pre-column oxidation of the sample. The method presented has potential for incorporation in to field-deployable devices for the early detection of PSTs on-site.
  5. Keyon AS, Guijt RM, Gaspar A, Kazarian AA, Nesterenko PN, Bolch CJ, et al.
    Electrophoresis, 2014 May;35(10):1496-503.
    PMID: 24591173 DOI: 10.1002/elps.201300353
    Paralytic shellfish toxins (PSTs) are produced by marine and freshwater microalgae and accumulate in shellfish including mussels, oysters, and scallops, causing possible fatalities when inadvertently consumed. Monitoring of PST content of shellfish is therefore important for food safety, with currently approved methods based on HPLC, using pre- or postcolumn oxidation for fluorescence detection (HPLC-FLD). CE is an attractive alternative for screening and detection of PSTs as it is compatible with miniaturization and could be implemented in portable instrumentation for on-site monitoring. In this study, CE methods were developed for C(4) D, FLD, UV absorption detection, and MS-making this first report of C(4) D and FLD for PSTs detection. Because most oxidized toxins are neutral, MEKC was used in combination with FLD. The developed CZE-UV and CZE-C(4) D methods provide better resolution, selectivity, and separation efficiency compared to CZE-MS and MEKC-FLD. The sensitivity of the CZE-C(4) D and MEKC-FLD methods was superior to UV and MS, with LOD values ranging from 140 to 715 ng/mL for CZE-C(4) D and 60.9 to 104 ng/mL for MEKC-FLD. With the regulatory limit for shellfish samples of 800 ng/mL, the CZE-C(4) D and MEKC-FLD methods were evaluated for the screening and detection of PSTs in shellfish samples. While the CZE-C(4) D method suffered from significant interferences from the shellfish matrix, MEKC-FLD was successfully used for PST screening of a periodate-oxidized mussel sample, with results confirmed by HPLC-FLD. This confirms the potential of MEKC-FLD for screening of PSTs in shellfish samples.
  6. Nanthasurasak P, See HH, Zhang M, Guijt RM, Breadmore MC
    Angew Chem Int Ed Engl, 2019 03 18;58(12):3790-3794.
    PMID: 30614157 DOI: 10.1002/anie.201812077
    An electrokinetic platform was developed for extracting small-molecule pharmaceuticals from a dried blood spot. Through the exclusion of liquid reagents and use of low field strength (6 V cm-1 ), the electroextraction of a drug from a dried blood spot, deposited on a polymer inclusion membrane (PIM), could be realised while in transit in the mail. In transit sample preparation provides a potential solution to in situ sample degradation and may accelerate the workflow upon arrival of a patient sample at the analytical facility. The electroextraction method was enabled through our discovery of the use of 15-20 μm thin PIMs as electrophoretic separation medium in absence of liquid reagents. Here, a PIM consisting of cellulose triacetate as polymer base, 2-nitrophenyl octyl ether as plasticizer and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide as carrier was used. The PIM, was packaged with two 12 V batteries to supply the separation voltage. A blood spot containing berberine chloride was deposited and dried before the applying the separation potential, allowing for the electroextraction while the packaged device was shipped in internal mail. Upon arrival in the analytical laboratory, the PIM was analysed using a fluorescence microscope with photon multiplier tube, quantifying the berberine extracted away from the sample matrix. This platform represents a new opportunity for processing clinical samples during transport to the laboratory, saving time and manual handling to accelerate the time to result.
  7. Nanthasurasak P, Cabot JM, See HH, Guijt RM, Breadmore MC
    Anal Chim Acta, 2017 Sep 08;985:7-23.
    PMID: 28864197 DOI: 10.1016/j.aca.2017.06.015
    Point-of-collection (POC) devices aim for a fast, on-site detection for medical and environmental purposes. In this area, microfluidic Paper-based Analytical Devices (μPADs) have recently gained popularity because these are potentially cheap and environmentally friendly to produce, and easy to use. From an analytical perspective, paper is well known for its use as a substrate for chromatography, but less known for its use in electrophoretic separations. With the recent interest in μPADs, most applications are based on rather simple assays with relatively few applications incorporating an analytical separation. The focus of this review is on paper-based electrophoresis, originating with the key developments in the 1940s and 1950s as well as the recent developments of electrophoretic μPADs, and concluding with a critical discussion of the opportunities and challenges for electrophoretic μPADS in the future.
  8. Ramanathan S, Lau WJ, Goh PS, Gopinath SCB, Rawindran H, Omar MF, et al.
    Mikrochim Acta, 2024 Sep 10;191(10):586.
    PMID: 39251454 DOI: 10.1007/s00604-024-06662-0
    A unique method for determining chlorophyll content in microalgae is devised employing a gold interdigitated electrode (G-IDE) with a 10-µm gap, augmented by a nano-molecularly imprinted polymer (nano-MIP) and a titanium dioxide/multiwalled carbon nanotube (TiO2/MWCNT) nanocomposite. The nano-MIP, produced using chlorophyll template voids, successfully trapped chlorophyll, while the TiO2/MWCNT nanocomposite, synthesized by the sol-gel technique, exhibited a consistent distribution and anatase crystalline structure. The rebinding of procured chlorophyll powder, which was used as a template for nano-MIP synthesis, was identified with a high determination coefficient (R2 = 0.9857). By combining the TiO2/MWCNT nanocomposite with nano-MIP, the G-IDE sensing method achieved a slightly better R2 value of 0.9892 for detecting chlorophyll in microalgae. The presented G-IDE sensor showed a significant threefold enhancement in chlorophyll detection compared with commercially available chlorophyll powder. It had a detection limit of 0.917 mL (v/v) and a linear range that spanned from 10-6 to 1 mL. The effectiveness of the sensor in detecting chlorophyll in microalgae was confirmed through validation of its repeatability and reusability.
  9. Breadmore MC, Wuethrich A, Li F, Phung SC, Kalsoom U, Cabot JM, et al.
    Electrophoresis, 2017 01;38(1):33-59.
    PMID: 27678139 DOI: 10.1002/elps.201600331
    One of the most cited limitations of capillary (and microchip) electrophoresis is the poor sensitivity. This review continues to update this series of biennial reviews, first published in Electrophoresis in 2007, on developments in the field of on-line/in-line concentration methods in capillaries and microchips, covering the period July 2014-June 2016. It includes developments in the field of stacking, covering all methods from field amplified sample stacking and large volume sample stacking, through to isotachophoresis, dynamic pH junction, and sweeping. Attention is also given to on-line or in-line extraction methods that have been used for electrophoresis.
  10. Breadmore MC, Grochocki W, Kalsoom U, Alves MN, Phung SC, Rokh MT, et al.
    Electrophoresis, 2019 01;40(1):17-39.
    PMID: 30362581 DOI: 10.1002/elps.201800384
    One of the most cited limitations of capillary and microchip electrophoresis is the poor sensitivity. This review continues to update this series of biannual reviews, first published in Electrophoresis in 2007, on developments in the field of online/in-line concentration methods in capillaries and microchips, covering the period July 2016-June 2018. It includes developments in the field of stacking, covering all methods from field-amplified sample stacking and large-volume sample stacking, through to isotachophoresis, dynamic pH junction, and sweeping. Attention is also given to online or in-line extraction methods that have been used for electrophoresis.