Displaying all 5 publications

Abstract:
Sort:
  1. Sacco A, Morici N, Belli O, Bossi I, Mafrici A, Klugmann S
    Med J Malaysia, 2011 Dec;66(5):520-1.
    PMID: 22390119
    We present a case of "inverted Tako-Tsubo" syndrome in a woman sedated with meperidine before undergoing a colonscopy. We discuss possible etiology of this ventricular dysfunction.
  2. Laricchia A, Bossi I, Latini RA, Lee CY, Pérez IS, Tomai F, et al.
    Rev Esp Cardiol (Engl Ed), 2024 Jul;77(7):527-536.
    PMID: 38056772 DOI: 10.1016/j.rec.2023.11.010
    INTRODUCTION AND OBJECTIVES: The PEACE study (Performance of a sirolimus-eluting balloon strategy in acute and chronic coronary syndromes) investigated for the first time whether a sirolimus-coated balloon (SCB) (Magic Touch, Concept Medical, India) is associated with different outcomes depending on whether it is used in acute coronary syndromes (ACS) or chronic coronary syndromes (CCS).

    METHODS: This was a post-hoc analysis from the all-comers EASTBOURNE Registry (NCT03085823). Out of 2083 patients enrolled, an SCB was used to treat 968 (46.5%) ACS and 1115 (53.5%) CCS patients. The primary endpoint was target lesion revascularization at 12 months, while secondary endpoints were angiographic success and major adverse cardiovascular events.

    RESULTS: Baseline demographics, mean reference vessel diameter and mean lesion length were comparable between ACS and CCS. Predilatation was more commonly performed in ACS (P=.007). SCB was inflated at a standard pressure in both groups with a slight trend toward longer inflation time in ACS. Angiographic success was high in both groups (ACS 97.4% vs CCS 97.7%, P=.820) with limited bailout stenting. Similarly, at 12 months the cumulative incidence of target lesion revascularization (ACS 6.6% vs CCS 5.2%, P=.258) was comparable between ACS and CCS. Conversely, a higher rate of major adverse cardiovascular events in acute presenters was mainly driven by myocardial infarction recurrencies (ACS 10.4% vs CCS 8.3%, P=.009). In-stent restenosis showed a higher proportion of target lesion revascularization and major adverse cardiovascular events than de novo lesions, independently of the type of presentation at the index procedure.

    CONCLUSIONS: This SCB shows good performance in terms of acute and 1-year outcomes independently of the clinical presentation.

  3. Cortese B, Testa L, Di Palma G, Heang TM, Bossi I, Nuruddin AA, et al.
    J Cardiovasc Med (Hagerstown), 2021 02 01;22(2):94-100.
    PMID: 32740442 DOI: 10.2459/JCM.0000000000001070
    AIMS: The purpose of the EASTBOURNE registry is to evaluate the immediate and long-term clinical performance of a novel sirolimus-coated balloon (SCB) in a real-world population of patients with coronary artery disease. We here present the prespecified interim analysis after the enrollment of the first 642 patients who obtained 1-year clinical follow-up.

    METHODS: EASTBOURNE is a prospective, international, multicenter, all-comer investigator-driven clinical registry, which is enrolling consecutive patients treated with SCB at 42 European and Asiatic centers. Primary study endpoint is target-lesion revascularization (TLR) at 12 months. Secondary endpoints are procedural success and major adverse cardiac events through 36 months.

    RESULTS: Diabetes mellitus was present in 41% of patients. Acute coronary syndrome was present in 45% of patients and de novo lesions were 55%; 83% of the in-stent restenosis (ISR) patients had drug-eluting stents restenosis. Lesion predilatation was performed in 95% of the cases and bailout stenting occurred in 7.5%. So far, 642 patients have a complete 12-month follow-up. TLR occurred in 2.5%, myocardial infarction in 2.3%, total death in 1% and major adverse cardiac events in 5.8% of patients. A prespecified analysis of comparison between ISR and de-novo lesions showed a significantly higher occurrence of TLR in the ISR population (5.4 vs. 0.2%, P = 0.0008).

    CONCLUSION: The current interim analysis of 12-month follow-up of the EASTBOURNE registry shows good immediate performance and an adequate and encouraging safety profile through 12 months for this novel SCB.

  4. Mangier A, Testa L, Heang TM, Bossi I, Lee CY, Perez IS, et al.
    Cardiovasc Revasc Med, 2024 Jul 30.
    PMID: 39191613 DOI: 10.1016/j.carrev.2024.07.024
    BACKGROUND: Drug coated balloons (DCB) are potentially less thrombogenic than drug eluting stents (DES).

    AIMS: To explore the safety and the feasibility of single antiplatelet therapy in percutaneous coronary intervention with sirolimus-coated balloons.

    METHODS: The All-comers Sirolimus-coated Balloon European Registry (EASTBOURNE) is a prospective investigator-driven registry assessing the performance of a novel sirolimus-coated balloon (SCB) in a real-world population. This prespecified post hoc analysis aimed at comparing the outcome in patients prescribed either single antiplatelet therapy (SAPT) or dual antiplatelet therapy (DAPT); choice of antiplatelet agent and duration of the regimen were at operator's discretion in both groups. Primary endpoint was target lesion revascularization (TLR) at 12 months. Secondary endpoints were bleeding grade 3-5 according to The Bleeding Academic Research Consortium (BARC) criteria and major adverse cardiovascular events (MACE) at 12 months follow-up.

    RESULTS: Among 2123 patients enrolled in the study between September 2016 and November 2020, 113 patients (5.8 %) received SAPT while 1826 patients (94.1 %) received DAPT after SCB. The majority of the patients underwent DCB PCI for de novo lesions (n = 1091, 56.3 %) while 848 patients (47.7 %) had DCB revascularization for in-stent restenosis. No cases of TLR occurred in the SAPT group within one month after the index procedure, and no acute occlusive events were recorded during follow up in patients taking a single antiplatelet agent. Moreover, no differences in terms of TLR were observed between SAPT vs DAPT regimens nor in case of de novo treatment with an overall rate of TLR at 12 months of 7.7 % for SAPT and 5.6 % for DAPT (p = 0.6). The cumulative rate of MACE at 12 months was not different between SAPT and DAPT regimens (n = 12 [11.2 %] vs. n = 162 [8.9 %], p = 0.4), and results were consistent in the de novo and in-stent restenosis groups.

    CONCLUSIONS: Our post hoc analysis of the EASTBOURNE registry suggests that the use of single antiplatelet agent after sirolimus-DCB PCI for both de novo or in-stent restenosis lesions is safe and effective and can help to contain the risk of bleeding in a selected population.

    CONDENSED ABSTRACT: The manuscript aims to explore the feasibility of a single antiplatelet regimen following angioplasty using drug coated balloon with sirolimus. Among 2123 patients treated with sirolimus coated balloon (SCB), 113 patients (5.8 %) received a single antiplatelet therapy (SAPT) while 1826 patients (94.1 %) received dual antiplatelet therapy DAPT. No cases of target lesion revascularization occurred in the SAPT group within one month after the index procedure, and no acute occlusive events were recorded during follow up in patients taking a single antiplatelet agent. The cumulative rate of major adverse cardiovascular events at 12 months was not different between SAPT and DAPT regimens and results were consistent in the de novo and in-stent restenosis groups.

  5. Cortese B, Testa L, Heang TM, Ielasi A, Bossi I, Latini RA, et al.
    JACC Cardiovasc Interv, 2023 Jul 24;16(14):1794-1803.
    PMID: 37495352 DOI: 10.1016/j.jcin.2023.05.005
    BACKGROUND: Drug-coated balloons (DCB) represent 1 of the most promising innovations in interventional cardiology and may represent a valid alternative to drug-eluting stents. Currently, some sirolimus-coated balloons (SCB) are being investigated for several coronary artery disease applications.

    OBJECTIVES: This study sought to understand the role of a novel SCB for the treatment of coronary artery disease.

    METHODS: EASTBOURNE (All-Comers Sirolimus-Coated Balloon European Registry) is a prospective, multicenter, investigator-driven clinical study that enrolled real-world patients treated with SCB. Primary endpoint was target lesion revascularization (TLR) at 12 months. Secondary endpoints were procedural success, myocardial infarction (MI), all-cause death, and major adverse clinical events (a composite of death, MI, and TLR). All adverse events were censored and adjudicated by an independent clinical events committee.

    RESULTS: A total population of 2,123 patients (2,440 lesions) was enrolled at 38 study centers in Europe and Asia. The average age was 66.6 ± 11.3 years, and diabetic patients were 41.5%. De novo lesions (small vessels) were 56%, in-stent restenosis (ISR) 44%, and bailout stenting occurred in 7.7% of the patients. After 12 months, TLR occurred in 5.9% of the lesions, major adverse clinical events in 9.9%, and spontaneous MI in 2.4% of the patients. The rates of cardiac/all-cause death were 1.5% and 2.5%, respectively. The primary outcome occurred more frequently in the ISR cohort (10.5% vs 2.0%; risk ratio: 1.90; 95% CI: 1.13-3.19). After multivariate Cox regression model, the main determinant for occurrence of the primary endpoint was ISR (OR: 5.5; 95% CI: 3.382-8.881).

    CONCLUSIONS: EASTBOURNE, the largest DCB study in the coronary field, shows the safety and efficacy of a novel SCB in a broad population of coronary artery disease including small vessels and ISR patients at mid-term follow-up. (The All-Comers Sirolimus-Coated Balloon European Registry [EASTBOURNE]; NCT03085823).

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links