Displaying all 2 publications

Abstract:
Sort:
  1. Abdul Keyon AS, Guijt RM, Bolch CJ, Breadmore MC
    J Chromatogr A, 2014 Oct 17;1364:295-302.
    PMID: 25223612 DOI: 10.1016/j.chroma.2014.08.074
    The accumulation of paralytic shellfish toxins (PSTs) in contaminated shellfish is a serious health risk making early detection important to improve shellfish safety and biotoxin management. Capillary electrophoresis (CE) has been proven as a high resolution separation technique compatible with miniaturization, making it an attractive choice in the development of portable instrumentation for early, on-site detection of PSTs. In this work, capillary zone electrophoresis (CZE) with capacitively coupled contactless conductivity detector (C(4)D) and UV detection were examined with counter-flow transient isotachophoresis (tITP) to improve the sensitivity and deal with the high conductivity sample matrix. The high sodium concentration in the sample was used as the leading ion while l-alanine was used as the terminating electrolyte (TE) and background electrolyte (BGE) in which the toxins were separated. Careful optimization of the injected sample volume and duration of the counter-flow resulted in limit of detections (LODs) ranging from 74.2 to 1020 ng/mL for tITP-CZE-C(4)D and 141 to 461 ng/mL for tITP-CZE-UV, an 8-97 fold reduction compared to conventional CZE. The LODs were adequate for the analysis of PSTs in shellfish samples close to the regulatory limit. Intra-day and inter-day repeatability values (percentage relative standard deviation, n=3) of tITP-CZE-C(4)D and tITP-CZE-UV methods for both migration time and peak height were in the range of 0.82-11% and 0.76-10%, respectively. The developed method was applied to the analysis of a contaminated mussel sample and validated against an Association of Official Analytical Chemists (AOAC)-approved method for PSTs analysis by high performance liquid chromatography (HPLC) with fluorescence detection (FLD) after pre-column oxidation of the sample. The method presented has potential for incorporation in to field-deployable devices for the early detection of PSTs on-site.
  2. Keyon AS, Guijt RM, Gaspar A, Kazarian AA, Nesterenko PN, Bolch CJ, et al.
    Electrophoresis, 2014 May;35(10):1496-503.
    PMID: 24591173 DOI: 10.1002/elps.201300353
    Paralytic shellfish toxins (PSTs) are produced by marine and freshwater microalgae and accumulate in shellfish including mussels, oysters, and scallops, causing possible fatalities when inadvertently consumed. Monitoring of PST content of shellfish is therefore important for food safety, with currently approved methods based on HPLC, using pre- or postcolumn oxidation for fluorescence detection (HPLC-FLD). CE is an attractive alternative for screening and detection of PSTs as it is compatible with miniaturization and could be implemented in portable instrumentation for on-site monitoring. In this study, CE methods were developed for C(4) D, FLD, UV absorption detection, and MS-making this first report of C(4) D and FLD for PSTs detection. Because most oxidized toxins are neutral, MEKC was used in combination with FLD. The developed CZE-UV and CZE-C(4) D methods provide better resolution, selectivity, and separation efficiency compared to CZE-MS and MEKC-FLD. The sensitivity of the CZE-C(4) D and MEKC-FLD methods was superior to UV and MS, with LOD values ranging from 140 to 715 ng/mL for CZE-C(4) D and 60.9 to 104 ng/mL for MEKC-FLD. With the regulatory limit for shellfish samples of 800 ng/mL, the CZE-C(4) D and MEKC-FLD methods were evaluated for the screening and detection of PSTs in shellfish samples. While the CZE-C(4) D method suffered from significant interferences from the shellfish matrix, MEKC-FLD was successfully used for PST screening of a periodate-oxidized mussel sample, with results confirmed by HPLC-FLD. This confirms the potential of MEKC-FLD for screening of PSTs in shellfish samples.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links