Displaying all 3 publications

Abstract:
Sort:
  1. Idris A, Yen OB, Hamid MH, Baki AM
    Water Sci Technol, 2002;46(9):279-86.
    PMID: 12448479
    A sludge lagoon has been adopted as a simple and cost effective method for dewatering of sludge. The processes occurring in a sludge lagoon include thickening, dewatering, storage and stabilization; all happening simultaneously. The objective of this study is to determine the dewatering and drying rates at pilot-scale which occur in a lagoon having different design configurations. Two types of sludge lagoons with different initial sludge depth (0.75 m and 0.375 m) were investigated to measure the drying behavior and drying efficiency. The first design is a sludge lagoon with a clay bottom where the dewatering mechanisms are decanting supernatant and evaporation. The second design is a sludge lagoon installed with a sand and underdrains system, where the dewatering mechanisms are filtration or draining and evaporation. Sludge drying kinetic models with high fitness were plotted to describe the sludge drying behavior. Drying of sludge in a sludge lagoon with a clay bottom can best be described by an exponential function. Whereas, drying of sludge in a sludge lagoon with sand and underdrains system followed a logarithmic function. A lagoon designed with sand and underdrains system and having shallower sludge depth was the most efficient. The reduction in volatile solids was lower than 4% during the study period. The drying process proceeded with an increase in dryness and decline in pH value.
  2. Baki AM, Ramli R, Noor RM, Mohamad I, Jais M
    Medeni Med J, 2020;35(3):276-280.
    PMID: 33110682 DOI: 10.5222/MMJ.2020.90093
    Nodular fasciitis (NF) is an uncommon and benign tumour-like fibroblastic proliferation that is difficult to distinguish from sarcoma both clinically and histologically. In addition, it is a type of lesion characterised by having a potential for spontaneous regression. NF is frequently misdiagnosed due to its rapid growth, rich cellularity, and mitotic figure. Although NF is only rarely diagnosed in children, the head and neck represent the most common locations for NF among this population. The cause of NF remains unknown, however trauma is believed to be an important triggering factor. We describe an unusual case of NF in the posterior ethmoid sinus in a six-year-old boy with no history of trauma. The NF was incidentally noted on a computed tomography scan after the patient complained of a squint. The diagnosis of NF was also supported by histopathology and specific immunohistological staining. A surgical biopsy was performed, and no recurrence was observed after one year.
  3. Liew AG, Idris A, Wong CH, Samad AA, Noor MJ, Baki AM
    Waste Manag Res, 2004 Aug;22(4):226-33.
    PMID: 15462329
    This study reports the use of sewage sludge generated from sewage treatment plant (STP) as raw material in a clay brick-making process. The physico-chemical and mineralogical characterization of the sewage sludge and clay were carried out in order to identify the major technological constraints and to define the sludge pretreatment requirements if necessary. Moreover, the effects on processing conditions and/or on changes of typical final characteristics are also evaluated. Bricks were produced with sewage sludge additions ranging from 10 to 40% by dry weight. The texture and finishing of the surface of sludge-amended clay bricks were rather poor. As for the physical and chemical properties, bricks with a sludge content of up to 40 wt.% were capable of meeting the relevant technical standards. However, bricks with more than 30 wt.% sludge addition are not recommended for use since they are brittle and easily broken even when handled gently. A tendency for a general degradation of brick properties with sludge additions was observed due to its refractory nature. Therefore, sludge bricks of this nature are only suitable for use as common bricks, which are normally not exposed to view, because of poor surface finishing.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links