A new lead(II) electrode has been constructed with poly(hydroxamic acid) (PHXA) as the active material and silicone rubber as the supporting material. The electrode gave near Nerstian response over the concentration range 4 x 10(-5)-1 x 10(-2)M lead(II). The detection limit of the electrode is approximately 4 x 10(-6)M and the electrode works well in the pH range 4.5-6.0. The response time was 50-120 sec over the whole concentration range and the electrode has a working life of at least 4 weeks. Iron(III) severely poisoned the electrode membrane. Nickel(II) and mercury(II) gave very strong interference compared to copper(II), silver(I), cobalt(II), sodium(I), potassium(I), zinc(II) and cadmium(II) which gave some or little interference. Values determined with atomic absorption (AAS) and a commercial lead(II) electrode were in good agreement with those measured with the lead(II) electrode reported here.
The prevalence of Capillaria hepatica (Bancroft, 1893) infection in a total of 2324 rats trapped from 25 localities in West Malaysia was 15.5%. Infection rates in males (16.0%) and females (15.1%) are similar. A significantly higher percentage of adults (18.1%) than young (7.7%) was infected. Capillaria hepatica infection rates among urban (0.7%) and jungle (0.0%) rats was very low as compared to field rats (17.7%) trapped from agricultural areas such as oil palm estates and rice growing areas. Prevalence of C. hepatica infection in rats is not evenly distributed throughout West Malaysia. There seem to be localised foci of infection. In some areas as many as 77.8% of the adult rats are found to be infected while in other areas the same species of rats are found free of infection.
OBJECTIVE: The aim is to find rate of return to work of surgically treated thoracolumbar fracture patients and to know if back pain, compensation issues or neurological status influence this rate.
METHODOLOGY: A retrospective cohort study analysing the patients with thoracolumbar fractures treated surgically from January 2008 till December 2009.
RESULTS: Neurological status is the main factor deciding return to work in this group. Back pain and compensation related issues were not statistically significant in influencing return to work. 74% of patients in this group return to work.
CONCLUSION: Return to work among the patients with thoracolumbar fracture, treated surgically, is mainly dependent on neurological status and not the compensation related issues or back pain.
During 1984-1985, a total of 838 sera obtained from individuals of different age groups, mostly blood donors and those whose sera were received for VDRL tests and other serological investigations. The sera were titrated for complement fixing antibodies against cytomegalovirus (Ad169 strain). Three hundred and fifty two (41%) out of 838 sera showed significant antibody titre. The incidence of this virus infection varied form 26% in the age group of 11-20 years to 59% of those above 50 years of age. Geometric mean titre (GMT) was highest (22) in age groups of 11-20 years and those over 50 years indicating active viral infection in these two age groups. GMT was also significantly higher in females in all age groups except in the age group of 21-30 years and those above 50 years, indicating that active viral infection is more common in females.
Recently, there has been increasing interest in electrochemical printed sensors for a wide range of applications such as biomedical, pharmaceutical, food safety, and environmental fields. A major challenge is to obtain selective, sensitive, and reliable sensing platforms that can meet the stringent performance requirements of these application areas. Two-dimensional (2D) nanomaterials advances have accelerated the performance of electrochemical sensors towards more practical approaches. This review discusses the recent development of electrochemical printed sensors, with emphasis on the integration of non-carbon 2D materials as sensing platforms. A brief introduction to printed electrochemical sensors and electrochemical technique analysis are presented in the first section of this review. Subsequently, sensor surface functionalization and modification techniques including drop-casting, electrodeposition, and printing of functional ink are discussed. In the next section, we review recent insights into novel fabrication methodologies, electrochemical techniques, and sensors' performances of the most used transition metal dichalcogenides materials (such as MoS2, MoSe2, and WS2), MXenes, and hexagonal boron-nitride (hBN). Finally, the challenges that are faced by electrochemical printed sensors are highlighted in the conclusion. This review is not only useful to provide insights for researchers that are currently working in the related area, but also instructive to the ones new to this field.
Skin plays an important role in defense against infection and other harmful biological agents. Due to its fragile structure, skin can be easily damaged by heat, chemicals, traumatic injuries and diseases. An autologous bilayered human skin equivalent, MyDerm™, was engineered to provide a living skin substitute to treat critical skin loss. However, one of the disadvantages of living skin substitute is its short shelf-life, hence limiting its distribution worldwide. The aim of this study was to evaluate the shelf-life of MyDerm™ through assessment of cell morphology, cell viability, population doubling time and functional gene expression levels before transplantation. Skin samples were digested with 0.6% Collagenase Type I followed by epithelial cells dissociation with TrypLE Select. Dermal fibroblasts and keratinocytes were culture-expanded to obtain sufficient cells for MyDerm™ construction. MyDerm™ was constructed with plasma-fibrin as temporary biomaterial and evaluated at 0, 24, 48 and 72 hours after storage at 4°C for its shelf-life determination. The morphology of skin cells derived from MyDerm™ remained unchanged across storage times. Cells harvested from MyDerm™ after storage appeared in good viability (90.5%±2.7% to 94.9%±1.6%) and had short population doubling time (58.4±8.7 to 76.9±19 hours). The modest drop in cell viability and increased in population doubling time at longer storage duration did not demonstrate a significant difference. Gene expression for CK10, CK14 and COL III were also comparable between different storage times. In conclusion, MyDerm™ can be stored in basal medium at 4°C for at least 72 hours before transplantation without compromising its functionality.
Animal-derivative free reagents are preferred in skin cell culture for clinical applications. The aim of this study was to compare the performance and effects between animal-derived trypsin and recombinant trypsin for skin cells culture and expansion. Full thickness human skin was digested in 0.6 % collagenase for 6 h to liberate the fibroblasts, followed by treatment with either animal-derived trypsin; Trypsin EDTA (TE) or recombinant trypsin; TrypLE Select (TS) to liberate the keratinocytes. Both keratinocytes and fibroblasts were then culture-expanded until passage 2. Trypsinization for both cell types during culture-expansion was performed using either TE or TS. Total cells yield was determined using a haemocytometer. Expression of collagen type I, collagen type III (Col-III), cytokeratin 10, and cytokeratin 14 genes were quantified via RT-PCR and further confirmed with immunocytochemical staining. The results of our study showed that the total cell yield for both keratinocytes and fibroblasts treated with TE or TS were comparable. RT-PCR showed that expression of skin-specific genes except Col-III was higher in the TS treated group compared to that in the TE group. Expression of proteins specific to the two cell types were confirmed by immunocytochemical staining in both TE and TS groups. In conclusion, the performance of the recombinant trypsin is comparable with the well-established animal-derived trypsin for human skin cell culture expansion in terms of cell yield and expression of specific cellular markers.