Displaying publications 1 - 20 of 46 in total

Abstract:
Sort:
  1. Faridah Y, Abdullah BJ
    Hong Kong Med J, 2003 Apr;9(2):134-6.
    PMID: 12668827
    Magnetic resonance imaging is gaining importance in the diagnosis of nerve and muscular disorders. The ability of magnetic resonance imaging to delineate the different muscles and the nerve in any plane has made the differentiation between the changes of neuropathy, denervation, and nerve entrapment possible. Although findings on magnetic resonance imaging are non-specific, their use, coupled with clinical symptoms and electromyographic findings, allow an accurate diagnosis to be made without resorting to invasive biopsies.
  2. Aminah M, Ng KH, Abdullah BJ, Jamal N
    Australas Phys Eng Sci Med, 2010 Dec;33(4):329-34.
    PMID: 20938762 DOI: 10.1007/s13246-010-0035-3
    The performance of a digital mammography system (Siemens Mammomat Novation) using different target/filter combinations and tube voltage has been assessed. The objective of this study is to optimize beam quality selection based on contrast-to-noise ratio (CNR) and mean glandular dose (MGD). Three composition of breast were studied with composition of glandular/adipose of 30/70, 50/50, and 70/30. CNR was measured using 2, 4 and 6 cm-thick simulated breast phantoms with an aluminium sheet of 0.1 mm thickness placed on top of the phantom. Three target/filter combinations, namely molybdenum/molybdenum (Mo/Mo), molybdenum/rhodium (Mo/Rh) and tungsten/rhodium (W/Rh) with various tube voltage and mAs were tested. MGD was measured for each exposure. For 50/50 breast composition, Mo/Rh combination with tube voltage 26 kVp is optimal for 2 cm-thick breast. W/Rh combination with tube voltage 27 and 28 kVp are optimal for 4 and 6 cm-thick breast, respectively. For both 30/70 and 70/30 breast composition, W/Rh combination is optimal with tube voltage 25, 26 and 27 kVp, respectively. From our study it was shown that there are potential of dose reduction up to 11% for a set CNR of 3.0 by using beam quality other than that are determined by AEC selection. Under the constraint of lowest MGD, for a particular breast composition, calcification detection is optimized by using a softer X-ray beam for thin breast and harder X-ray beam for thick breast. These experimental results also indicate that for breast with high fibroglandular tissues (70/30), the use of higher beam quality does not always increase calcification detection due to additional structured noise caused by the fibroglandular tissues itself.
  3. Abdullah BJ, Bux SI, Chien D
    Med J Malaysia, 1997 Dec;52(4):445-53; quiz 454.
    PMID: 10968127
    MRI is now an important diagnostic tool in medical management. There are numerous safety issues to be considered by the clinicians prior to requesting an MRI examination for their patients. These include those related to the magnetic field, gradient magnetic fields, the patient and contrast medium. This paper discusses the dangers and necessary precautions essential to reduce the risk of untoward complications from MRI.
  4. Abdullah BJ, Kaur H, Ng KH
    Br J Radiol, 1998 Sep;71(849):930-3.
    PMID: 10195007
    Dried fish bones from eight species of Malaysian fish were placed in an animal cadaver at four sites (tonsil, valleculae, larynx and oesophagus) and radiographed using a double and a single film-screen combination. The use of the single film-screen combination resulted in visibility of all fish bones placed in the larynx, two of which were not visible on the double film-screen combination. There was a 50% increase of the visibility of the fish bones in the oesophagus using the single film-screen combination. The difference in dose and cost between the two different film-screen combinations was not significant.
  5. Ng KH, Abdullah BJ, Sivalingam S
    Health Phys, 1999 Jul;77(1):33-6.
    PMID: 10376539
    The medical radiation usage for diagnostic radiology in Malaysia (a Level II country) for 1990-1994 is reported, enabling a comparison to be made for the first time with the United Nations Scientific Committee on the Effects of Atomic Radiation Report. In 1994, the number of physicians, radiologists, x-ray units, and x-ray examinations per 1,000 population was 0.45, 0.005, 0.065, and 183, respectively. (Level I countries had averages of 2.6, 0.072, 0.35, and 860, respectively). In 1994, a total of 3.6 million x-ray examinations were performed; the annual effective dose per capita to the population was 0.05 mSv, and the collective effective dose was 1,000 person-Sv. Chest examinations contributed 63% of the total. Almost all examinations experienced increasing frequency from 1990 to 1994 except for barium studies, cholecystography, and intravenous urography (-23%, -36%, -51%). These decreases are related to the increasing use of ultrasound and greater availability of fiberoptic endoscopy. Notable increases during the same period were observed in computed tomography (161%), cardiac procedures (190%), and mammography (240%). In order to progress from Level II to Level I status Malaysia needs to expand and upgrade radiological service in tandem with the health care development of the country.
  6. Abdullah BJ, Ng KH, Pathmanathan R
    Med J Malaysia, 1999 Jun;54(2):169-74.
    PMID: 10972025
    Teleradiology is the most mature and rapidly evolving specialty in telemedicine. The use of teleradiology has grown tremendously during the past few years. This article describes the role of teleradiology in health care along with a brief history of its development in tandem with advances in telecommunications and computer technologies. Teleradiology standards, image acquisition, data compression, transmission and image interpretation are summarised. The impact of teleradiology in the practice of radiology, traces the evolution of the modality especially in the Malaysian perspective and its current and future role are discussed.
  7. Hashim S, Abdullah BJ, Rajasingam V, Moosa F
    Med J Malaysia, 1999 Jun;54(2):267-9.
    PMID: 10972041
    A 17 year old Malay student who is a known case of synovial sarcoma of left elbow (treated with an above elbow amputation) presented with duodenal obstruction. We report an unusual case of gastrointestinal tract metastases from synovial sarcoma. To our knowledge, there is no previous such report in the literature. The computed tomography (CT) and magnetic resonance imaging (MRI) features are described.
  8. Abdullah BJ, Teong LK, Mahadevan J, Jalaludin A
    J Otolaryngol, 1998 Aug;27(4):190-4.
    PMID: 9711512
    Impacted foreign bodies in the trachea and esophagus are common. In the esophagus, these are usually bones, while for the trachea, it is commonly some form of seed or nut. The incidence of impacted dental prostheses is not highlighted in the literature. They usually have a definite history of ingestion, frequently during trauma, seizures, or sleep. Prompt management in a safe and effective manner is required if significant morbidity, and even mortality, is to be avoided.
  9. Dabbagh A, Abdullah BJ, Ramasindarum C, Abu Kasim NH
    Ultrason Imaging, 2014 Oct;36(4):291-316.
    PMID: 24626566 DOI: 10.1177/0161734614526372
    Tissue-mimicking phantoms that are currently available for routine biomedical applications may not be suitable for high-temperature experiments or calibration of thermal modalities. Therefore, design and fabrication of customized thermal phantoms with tailored properties are necessary for thermal therapy studies. A multitude of thermal phantoms have been developed in liquid, solid, and gel forms to simulate biological tissues in thermal therapy experiments. This article is an attempt to outline the various materials and techniques used to prepare thermal phantoms in the gel state. The relevant thermal, electrical, acoustic, and optical properties of these phantoms are presented in detail and the benefits and shortcomings of each type are discussed. This review could assist the researchers in the selection of appropriate phantom recipes for their in vitro study of thermal modalities and highlight the limitations of current phantom recipes that remain to be addressed in further studies.
  10. Dabbagh A, Abdullah BJ, Abu Kasim NH, Ramasindarum C
    Int J Hyperthermia, 2014 Feb;30(1):66-74.
    PMID: 24286257 DOI: 10.3109/02656736.2013.854930
    The emergence of thermal modalities has promoted the use of heat-sensitive phantoms for calibration, measurement, and verification purposes. However, development of durable phantoms with high precision ability to represent the temperature distribution remains a challenge. This study aims to introduce a reusable phantom that provides an accurate assessment of the heated region in various thermal modalities.
  11. Manikam J, Mahadeva S, Goh KL, Abdullah BJ
    Hepatogastroenterology, 2009 Jan-Feb;56(89):227-30.
    PMID: 19453063
    Spontaneous rupture and hemorrhage is a devastating complication of hepatocellular carcinoma (HCC). Results from current therapeutic modalities remain varied. Recent development of percutaneous radiofrequency ablation (RFA) in the management of this condition has shown promise. We describe 2 cases of ruptured HCC in which nonoperative, percutaneous radio frequency ablation (RFA) was successful in achieving hemostasis. The advantageous of RFA over other interventional techniques in the management of ruptured HCC are discussed.
  12. Ramli K, Abdullah BJ, Ng KH, Mahmud R, Hussain AF
    Australas Radiol, 2005 Dec;49(6):460-6.
    PMID: 16351609
    The aim of this study was to compare the image quality and entrance skin dose (ESD) for film-screen and computed chest radiography. Analysis of the image quality and dose on chest radiography was carried out on a conventional X-ray unit using film-screen, storage phosphor plates and selenium drum direct chest radiography. For each receptor, ESD was measured in 60 patients using thermoluminescent dosemeters. Images were printed on 35 x 43 cm films. Image quality was assessed subjectively by evaluation of anatomic features and estimation of the image quality, following the guidelines established by the protocols of the Commission of the European Communities. There was no statistically significant difference noted between the computed and conventional images (Wilcoxon rank sum test, P > 0.05). Imaging of the mediastinum and peripheral lung structures were better visualized with the storage phosphor and selenium drum technique than with the film-screen combination. The patients' mean ESD for chest radiography using the storage phosphor, film-screen combination and selenium drum was 0.20, 0.20 and 0.25 mGy, respectively, with no statistically significant difference with P > 0.05 (chi(2) tests).
  13. Tan SP, Abdullah BJ, Waran V, Liew WF
    Neuroradiology, 2003 Jan;45(1):53-5.
    PMID: 12525956
    We present a rare indirect nontraumatic cerebrospinal fluid (CSF) fistula secondary to a fourth ventricle ependymoma. The fistula resulted from rupture of the left temporal horn, distant from the tumour. The fistula was well demonstrated by MRI. High-resolution CT demonstrated a defect in the roof of the sphenoid sinus, but no leakage of CSF was seen on CT cisternography.
  14. Lim CK, Yew KM, Ng KH, Abdullah BJ
    Australas Phys Eng Sci Med, 2002 Sep;25(3):144-50.
    PMID: 12416592 DOI: 10.1007/BF03178776
    Development of computer-based medical inference systems is always confronted with some difficulties. In this paper, difficulties of designing an inference system for the diagnosis of arthritic diseases are described, including variations of disease manifestations under various situations and conditions. Furthermore, the need for a huge knowledge base would result in low efficiency of the inference system. We proposed a hierarchical model of the fuzzy inference system as a possible solution. With such a model, the diagnostic process is divided into two levels. The first level of the diagnosis reduces the scope of diagnosis to be processed by the second level. This will reduce the amount of input and mapping for the whole diagnostic process. Fuzzy relational theory is the core of this system and it is used in both levels to improve the accuracy.
  15. Abdullah BJ, Mohd Yusof MY, Khoo BH
    Clin Radiol, 1998 Mar;53(3):212-4.
    PMID: 9528873
    Nosocomial infections are posing an increasingly serious problem in the hospital setting. With the increasing use of ultrasound in medical diagnosis, there is the potential for transmission of nosocomial infections via the ultrasound transducer and coupling gel. We evaluated the use of different membranes (three types of commercially available household cling film, condom, surgical glove and Opsite) applied over the ultrasound probe to determine if these were safe, convenient, cost-effective and did not impair the performance parameters of the ultrasound probe. None of the membranes impaired the physical scanning parameters using a Multi-Purpose Tissue/Cyst Phantom. The cling film was ideal for general use in terms of cost and convenience as well as safety. For sterile use the Opsite was better overall compared to the surgical glove, though it costs significantly more. The condom and surgical glove, though safe, were not very convenient to use for scanning.
  16. Abdullah BJ, Liam CK, Kaur H, Mathew KM
    Br J Radiol, 1997 Oct;70(838):1063-5.
    PMID: 9404213
    Lipoma of the parapharyngeal space is very rare, only three cases having been reported in the literature. A parapharyngeal space lipoma causing obstructive sleep apnoea has not been reported before. A 60-year-old man presented at the ear, nose and throat (ENT) clinic with a history of loud snoring associated with sleep apnoea secondary to a right parapharyngeal space lipoma. The causes of sleep apnoea and the radiological features of a parapharyngeal space lipoma are discussed.
    Study site: ENT clinic, University Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia
  17. Sarji SA, Abdullah BJ, Kumar G, Tan AH, Narayanan P
    Australas Radiol, 1998 Nov;42(4):293-5.
    PMID: 9833363
    A recognized cause of incomplete or cancelled MRI examinations is anxiety and claustrophobic symptoms in patients undergoing MR scanning. This appears to be a problem in many MRI centres in Western Europe and North America, where it is said to be costly in terms of loss of valuable scan time, and has led to researchers suggesting several anxiety-reducing approaches for MRI. To determine the incidence of failed MRI examination among our patients and if there are any associations with a patient's sex, age and education level, we studied claustrophobia that led to premature termination of the MRI examination in the University Malaya Medical Centre (UMMC) in 3324 patients over 28 months. The incidence of failed MRI examinations due to claustrophobia in the UMMC was found to be only 0.54%. There are associations between claustrophobia in MRI with the patients' sex, age and level of education. The majority of those affected were male patients and young patients in the 25-45-years age group. The patients' education level appears to be the strongest association with failed MRI examinations due to claustrophobia, where the majority of the affected were highly educated individuals. Claustrophobia in MRI is more of a problem among the educated individuals or patients from a higher socio-economic group, which may explain the higher incidence in Western European and North American patients.
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links