  1. Suhaimi SMI, Muhamad NA, Bashir N, Mohd Jamil MK, Abdul Rahman MN
    Sensors (Basel), 2022 Jan 18;22(3).
    PMID: 35161466 DOI: 10.3390/s22030722
    Flashover on transmission line insulators is one of the major causes of line outages due to contamination from the environment or ageing. Power utility companies practicing predictive maintenance are currently exploring novel non-contact methods to monitor insulator surface discharge activities to prevent flashover. This paper presents an investigation on the UV pulse signals detected using UV pulse sensor due to the discharges on the insulator surfaces under varying contamination levels and insulator ages. Unaged and naturally aged insulators (0 to >20 years) were artificially contaminated (none, light to heavy contamination). The electrical stresses on the insulator surfaces were varied to generate varying discharge intensity levels on the surfaces of the insulator. The DC and harmonic components of UV pulse signals detected during surface discharges were recorded and analysed. Results show a positive correlation between the discharge intensity level of contaminated and aged transmission insulators with the DC and harmonic components of the UV pulse signals. Furthermore, the study revealed that under dry insulator surface conditions, insulator ageing has a more profound effect during discharges than contamination level. The findings from this study suggest that the use of UV pulse sensors to monitor UV pulse signals emitted during insulator surface discharges can be another novel non-contact method of monitoring transmission line insulator surface conditions.
  2. Awang S, Alias N, DeWitt D, Jamaludin KA, Abdul Rahman MN
    Front Public Health, 2021;9:726647.
    PMID: 34869147 DOI: 10.3389/fpubh.2021.726647
    Cardiothoracic intensive care unit (CICU) nurses have shared the role and responsibility for ventilator-weaning to expedite decision-making in patient care. However, the actions taken are based on individual's unstructured training experience as there is no clinical practice guideline (CPG) for nurses in Malaysia. Hence, this study aims to design a CPG for the process of weaning from mechanical ventilation (MV) for a structured nursing training in a CICU at the National Heart Institute (Institut Jantung Negara, IJN) Malaysia. The Fuzzy Delphi Method (FDM) was employed to seek consensus among a panel of 30 experts in cardiac clinical practice on the guidelines. First, five experts were interviewed and their responses were transcribed and analyzed to develop the items for a FDM questionnaire. The questionnaire, comprising of 73 items, was distributed to the panel and their responses were analyzed for consensus on the design of the CPG. The findings suggested that the requirements expected for the nurses include: (a) the ability to interpret arterial blood gases, (b) knowledge and skills on the basics of mechanical ventilation, and (c) having a minimum 1-year working experience in the ICU. On the other hand, the CPG should mainly focus on developing an ability to identify criteria of patient eligible for weaning from MV. The learning content should focus on: (a) developing the understanding and reasoning for weaning and extubating and (b) technique/algorithm for extubating and weaning. Also, the experts agreed that the log book/competency book should be used for evaluation of the program. The CPG for structured nursing training at IJN in the context of the study is important for developing the professionalism of CICU nurses in IJN and could be used for training nurses in other CICUs, so that decision for ventilator-weaning from postcardiac surgery could be expedited.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links