Displaying publications 141 - 160 of 173 in total

Abstract:
Sort:
  1. Lee MW
    Int Ophthalmol, 2024 Jul 24;44(1):334.
    PMID: 39046597 DOI: 10.1007/s10792-024-03247-x
    PURPOSE: To evaluate the clinical outcomes following bilateral implantation of the AcrySof™ IQ Vivity™ toric extended depth of focus (EDOF) intraocular lens (IOL).

    DESIGN: Prospective interventional case series.

    METHODS: Patients with bilateral significant cataracts and pre-existing corneal astigmatism underwent cataract surgery and implantation with the AcrySof™ IQ Vivity™ toric IOL. Dominant eyes were targeted at emmetropia and non-dominant eyes at -0.50D. Primary endpoints were binocular uncorrected distance (UDVA), intermediate (UIVA at 66 cm) and near (UNVA at 40 cm) acuities at 3 months. Secondary outcomes were corrected distance (CDVA), distance corrected intermediate (DCIVA) and distance corrected near (DCNVA), refractive predictability, rotational stability, binocular defocus curve, contrast sensitivity, Questionnaire for Visual Disturbances (QUVID) and Visual Function Index (VF-14) questionnaire scores. All visual acuities were converted to logarithm of minimum angle of resolution (logMAR) for analysis.

    RESULTS: 30 patients underwent uneventful phacoemulsification. The mean binocular UDVA, UIVA and UNVA were 0.06 ± 0.12, 0.11 ± 0.10 and 0.26 ± 0.10 respectively. The mean refractive spherical equivalent (MRSE) for dominant and non-dominant eyes were - 0.07D ± 0.27 and - 0.12D ± 0.54 respectively. 92.4% of dominant eyes and 84.6% of non-dominant eyes within 0.50D of target. The mean IOL rotation was 3.85° ± 5.09 with 86.7% of eyes with less than 5° of rotation. 26.7%, 20% and 36.7% of patients reported starbursts, haloes and glare respectively. The mean VF-14 score was 91.77.

    CONCLUSION: Bilateral implantation of the AcrySof™ IQ Vivity™ Toric IOL resulted in very good unaided visual acuities for far and intermediate distance with functional near vision. Dysphotopsias were reported but despite this, a high level of visual function was achieved.

    Matched MeSH terms: Prosthesis Design
  2. Patil PG, Nimbalkar-Patil SP, Karandikar AB
    J Contemp Dent Pract, 2014 Jan 1;15(1):112-5.
    PMID: 24939276
    This case report demonstrates sequential periodontic, orthodontic and prosthodontic treatment modalities to save and restore deep horizontally fractured maxillary central incisor. The location of fracture was deep in the mucosa which reveals less than 2 mm of tooth structure to receive the crown. The procedures like surgical crown lengthening, endodontic post placement, orthodontic forced eruption, core build-up and metal-ceramic crown restoration were sequentially performed to conserve the fractured tooth. Forced eruption is preferred to surgical removal of supporting alveolar bone, since forced eruption preserves the biologic width, maintains esthetics, and at the same time exposes sound tooth structure for the placement of restorative margins.
    Matched MeSH terms: Dental Prosthesis Design
  3. Baharuddin MY, Salleh ShH, Hamedi M, Zulkifly AH, Lee MH, Mohd Noor A, et al.
    Biomed Res Int, 2014;2014:478248.
    PMID: 24800230 DOI: 10.1155/2014/478248
    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing.
    Matched MeSH terms: Prosthesis Design
  4. Ng KL, Nawawi O, Lim BK, Htun TH, Dublin N, Razack AH
    Asian J Surg, 2017 Apr;40(2):171-174.
    PMID: 24210538 DOI: 10.1016/j.asjsur.2013.09.012
    Ureteric strictures are common and can be due to benign or malignant causes. Various surgical treatments can be used from minimally invasive endoscopic retrograde JJ stent insertion, balloon dilatation, ureterolithotomy, to open surgical exploration and repair. Memokath 051 stent is a metallic stent designed for long-term ureteral stenting in the management of ureteral strictures. The insertion of this device is usually a straightforward procedure performed endoscopically in a retrograde fashion via cystoscopy. However, this procedure can be difficult in complicated scenarios when the bladder has been removed with neoureteral reimplantations or high-grade strictures. Here, we report a case of Memokath stent insertion complicated by placement difficulties in a lady with ileal conduit due to previous ovarian cancer complicated by vesicovaginal fistula, who presented with malignant stricture of the ureteroileal anastomosis. We describe a simple yet effective antegrade technique to precisely reposition the malpositioned Memokath stent, along with illustrations.
    Matched MeSH terms: Prosthesis Design
  5. Lee SY, Wee AS, Lim CK, Abbas AA, Selvaratnam L, Merican AM, et al.
    J Mater Sci Mater Med, 2013 Jun;24(6):1561-70.
    PMID: 23512151 DOI: 10.1007/s10856-013-4907-4
    This study aims to pre-assess the in vitro and in vivo biocompatibility of poly(vinyl alcohol)-carboxylmethyl-chitosan-poly(ethylene glycol) (PCP) scaffold. PCP was lyophilised to create supermacroporous structures. 3-(4, 5-dimethyl-thiazol-2yl)-2, 5-diphenyltetrazolium bromide (MTT) assay and immunohistochemistry (IHC) were used to evaluate the effectiveness of PCP scaffolds for chondrocytes attachment and proliferation. The ultrastructural was assessed using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Extracellular matrix (ECM) formation was evaluated using collagen type-II staining, glycosaminoglycan (GAG) and collagen assays. Histological analysis was conducted on 3-week implanted Sprague-Dawley rats. The MTT, IHC, SEM and TEM analyses confirm that PCP scaffolds promoted cell attachment and proliferation in vitro. The chondrocyte-PCP constructs secreted GAG and collagen type-II, both increased significantly from day-14 to day-28 (P 
    Matched MeSH terms: Prosthesis Design
  6. Chin K
    EuroIntervention, 2011 May;7 Suppl K:K43-6.
    PMID: 22027726 DOI: 10.4244/EIJV7SKA7
    In-stent restenosis remains an important issue even in the drug-eluting stent (DES) era today. In recent years, drug-eluting balloons (DEB) have emerged as a potential alternative to the treatment of in-stent restenosis. Paclitaxel was identified as the primary drug for DEB because of its rapid uptake and prolonged retention. Non-stent-based local drug delivery using DEB maintains the antiproliferation properties of DES, but without the limitations of DES such as subacute stent thrombosis, stent fractures, prolonged antiplatelet therapy and more importantly, avoiding a "stent-in-a-stent" approach. The first major impact of drug-eluting balloon (DEB) in the management of bare metal instent restenosis was the "PACCOCATH ISR I" randomised trial, comparing the efficacy of drug-eluting balloon versus uncoated balloon. The six months angiographic results showed a binary restenosis of 5% and 4% MACE in the drug-eluting balloon group, compared with 43% binary restenosis and 31% MACE, in the uncoated balloon group (p=0.002 and 0.02). The second major DEB trial is the "PEPCAD II Trial", comparing the efficacy of the SeQuent Please DEB with the Taxus drug-eluting stent in the treatment of bare-metal stent instent restenosis. At 6-month follow-up, in-segment late lumen loss was 0.38 ± 0.61 mm in the DES group versus 0.17 ± 0.42 mm (p=0.03) in the DEB group, resulting in a binary restenosis rate of 12/59 (20%) versus 4/57 (7%; p=0.06). At 12 months, MACE rates were 22% in the Taxus group and 9% in the DEB group (P=0.08). The TLR at 12 months was 15% in the Taxus group and 6% in the DEB group (p=0.15). Based on these two pivotal trials, the European Society of Cardiology Guidelines for Percutaneous Coronary Intervention (2010) recommended that DEB should be considered for the treatment of in-stent restenosis after prior bare-metal stent. This was accorded a class 2 IIa indication, with a level B evidence.
    Matched MeSH terms: Prosthesis Design
  7. Chai WL, Moharamzadeh K, Brook IM, Emanuelsson L, Palmquist A, van Noort R
    J. Periodontol., 2010 Aug;81(8):1187-95.
    PMID: 20450401 DOI: 10.1902/jop.2010.090648
    In dental implant treatment, the long-term prognosis is dependent on the biologic seal formed by the soft tissue around the implant. The in vitro investigation of the implant-soft tissue interface is usually carried out using a monolayer cell-culture model that lacks a polarized-cell phenotype. This study developed a tissue-engineered three-dimensional oral mucosal model (3D OMM) to investigate the implant-soft tissue interface.
    Matched MeSH terms: Dental Prosthesis Design
  8. Urban P, Meredith IT, Abizaid A, Pocock SJ, Carrié D, Naber C, et al.
    N Engl J Med, 2015 Nov 19;373(21):2038-47.
    PMID: 26466021 DOI: 10.1056/NEJMoa1503943
    BACKGROUND: Patients at high risk for bleeding who undergo percutaneous coronary intervention (PCI) often receive bare-metal stents followed by 1 month of dual antiplatelet therapy. We studied a polymer-free and carrier-free drug-coated stent that transfers umirolimus (also known as biolimus A9), a highly lipophilic sirolimus analogue, into the vessel wall over a period of 1 month.
    METHODS: In a randomized, double-blind trial, we compared the drug-coated stent with a very similar bare-metal stent in patients with a high risk of bleeding who underwent PCI. All patients received 1 month of dual antiplatelet therapy. The primary safety end point, tested for both noninferiority and superiority, was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy end point was clinically driven target-lesion revascularization.
    RESULTS: We enrolled 2466 patients. At 390 days, the primary safety end point had occurred in 112 patients (9.4%) in the drug-coated-stent group and in 154 patients (12.9%) in the bare-metal-stent group (risk difference, -3.6 percentage points; 95% confidence interval [CI], -6.1 to -1.0; hazard ratio, 0.71; 95% CI, 0.56 to 0.91; P<0.001 for noninferiority and P=0.005 for superiority). During the same time period, clinically driven target-lesion revascularization was needed in 59 patients (5.1%) in the drug-coated-stent group and in 113 patients (9.8%) in the bare-metal-stent group (risk difference, -4.8 percentage points; 95% CI, -6.9 to -2.6; hazard ratio, 0.50; 95% CI, 0.37 to 0.69; P<0.001).
    CONCLUSIONS: Among patients at high risk for bleeding who underwent PCI, a polymer-free umirolimus-coated stent was superior to a bare-metal stent with respect to the primary safety and efficacy end points when used with a 1-month course of dual antiplatelet therapy. (Funded by Biosensors Europe; LEADERS FREE ClinicalTrials.gov number, NCT01623180.).
    Matched MeSH terms: Prosthesis Design
  9. Arif M, Sivananthan S, Choon DS
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):25-30.
    PMID: 15237118
    To report the outcome of revised total hip arthroplasty procedures involving an anterior cortical window, extensive strut allografts, and an Exeter impaction graft.
    Matched MeSH terms: Prosthesis Design
  10. Subramaniam R, Mani MP, Jaganathan SK
    Cardiovasc Eng Technol, 2018 09;9(3):503-513.
    PMID: 29700782 DOI: 10.1007/s13239-018-0357-y
    In this study, a small vascular graft based on polyurethane (PU) blended with chitosan (Ch) nanoparticles was fabricated using electrospinning technique. Initially, the chitosan nanoparticles were synthesized using ionic gelation method. UV-Vis spectrophotometer confirmed the presence of synthesized Ch nanoparticles by exhibiting absorption peak at 288 nm and the Fourier-transform infrared spectroscopy (FTIR) analysis confirmed the existence of the chitosan. Further, the synthesized Ch nanoparticles showed size diameter in the range of 134 ± 58 nm as measured using ImageJ. In the electrospun PU/chitosan graft, the fiber diameter and pore size diameter was found to be reduced compared to the pure PU owing to incorporation of chitosan into PU matrix. The FTIR spectrum revealed the presence of chitosan in the prepared nanocomposite membrane by the formation of the hydrogen bond and peak shift of CH and NH stretching. Moreover, the contact angle measurements revealed that the prepared graft showed decreased contact angle indicating hydrophilic nature compared to the pristine PU. The cytocompatibility studies revealed the non-toxic behavior of the fabricated graft. Hence, the prepared graft exhibiting significant physiochemical and non-toxic properties may be a plausible candidate for cardiovascular graft applications.
    Matched MeSH terms: Prosthesis Design
  11. Abbas SS, Nasif MS, Al-Waked R, Meor Said MA
    Artif Organs, 2020 Feb;44(2):E20-E39.
    PMID: 31378963 DOI: 10.1111/aor.13536
    Platelet activation induced by shear stresses and non-physiological flow field generated by bileaflet mechanical heart valves (BMHVs) leads to thromboembolism, which can cause fatal consequences. One of the causes of platelet activation could be intermittent regurgitation, which arises due to asynchronous movement and rebound of BMHV leaflets during the valve closing phase. In this numerical study, the effect of intermittent regurgitation on the platelet activation potential of BMHVs was quantified by modeling a BMHV in the straight and anatomic aorta at implantation tilt angles 0°, 5°, 10°, and 20°. A fully implicit Arbitrary Lagrangian-Eulerian-based Fluid-Structure Interaction formulation was adopted with blood modeled as a multiphase, non-Newtonian fluid. Results showed that the intermittent regurgitation and consequently the platelet activation level increases with the increasing implantation tilt of BMHV. For the straight aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 20° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 8.5°, 3°, and 0°, respectively. For the anatomic aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 24° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 14°, 10°, and 7°, respectively. For all the implantation orientations of BMHVs, intermittent regurgitation and platelet activation were always higher in the anatomic aorta than in the straight aorta. The study concludes that the pivot axis of BMHV must be implanted parallel to the aortic root's curvature to minimize intermittent regurgitation and platelet activation.
    Matched MeSH terms: Prosthesis Design
  12. Basri AA, Zuber M, Basri EI, Zakaria MS, Aziz AFA, Tamagawa M, et al.
    Comput Math Methods Med, 2020;2020:9163085.
    PMID: 32454886 DOI: 10.1155/2020/9163085
    This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient's aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA.
    Matched MeSH terms: Prosthesis Design
  13. Promphan W, Han Siang K, Prachasilchai P, Jarutach J, Makonkawkeyoon K, Siwaprapakorn W, et al.
    Catheter Cardiovasc Interv, 2020 09 01;96(3):E310-E316.
    PMID: 32299151 DOI: 10.1002/ccd.28892
    OBJECTIVES: To assess feasibility and early outcomes of using BeGraft Aortic stent in the treatment of aortic coarctation (CoA).

    BACKGROUND: BeGraft Aortic stent (Bentley InnoMed, Hechingen, Germany) allows large postdilation diameter up to 30 mm. With availability of lengths of 19-59 mm and lower stent profile, they can be used in native and recurrent CoA in adults and in pediatric patients.

    MATERIALS AND METHODS: This is a multicentre retrospective analysis of 12 implanted BeGraft Aortic stents in CoA between May 2017 and April 2019.

    RESULTS: Twelve patients aged 7.7-38 years (median 18.3 years) with body weight of 19.9-56 kg (median 45.5 kg). Eight patients (66%) had native juxtaductal CoA while four had recurrent CoA after previous surgical or transcatheter treatments. The stents were implanted successfully in all the patients with no serious adverse events. The length of the stents ranged from 27 to 59 mm and the implanted stent diameter varied from 12 to 18 mm. The median intraprocedural CoA pressure gradient decreased from 25 mmHg (range 16-66 mmHg) to 2 mmHg (range 0-13 mmHg). The mean follow-up duration was 10.2 months. Two patient (16.6%) had residual stent narrowing requiring staged redilation. One patient (8%) had pseudoaneurysm formation at 1 year cardiac CT follow-up.

    CONCLUSIONS: The BeGraft Aortic stent may be considered to be safe and effective in the short term in treatment of CoA from childhood to adulthood. Long-term follow-up is needed.

    Matched MeSH terms: Prosthesis Design
  14. Lee CK, Chua YP, Saw A
    Clin Orthop Relat Res, 2012 Feb;470(2):610-5.
    PMID: 21842299 DOI: 10.1007/s11999-011-1990-z
    Pin site infection is a common problem in external fixation. Plain gauze wetted with normal saline is commonly used for a pin site dressing owing to the simplicity and low cost. Evidence to support adding an antimicrobial agent in the dressing material is lacking.
    Matched MeSH terms: Prosthesis Design
  15. Campos CM, Caixeta A, Franken M, Bartorelli AL, Whitbourn RJ, Wu CJ, et al.
    Catheter Cardiovasc Interv, 2018 02 15;91(3):387-395.
    PMID: 28471086 DOI: 10.1002/ccd.27109
    OBJECTIVES: to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA) BACKGROUND: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon.

    METHODS: The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR).

    RESULTS: After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups.

    CONCLUSION: In this largest ever patient-level pooled comparison on the treatment of diabetic patients with BRS out to two years, individuals with diabetes treated with the Absorb BVS had a similar rate of MACE as compared with diabetics treated with the Xience EES. © 2017 Wiley Periodicals, Inc.

    Matched MeSH terms: Prosthesis Design
  16. Ajit Singh V, Earnest Kunasingh D, Haseeb A, Yasin NF
    J Orthop Surg (Hong Kong), 2019 5 30;27(2):2309499019850313.
    PMID: 31138060 DOI: 10.1177/2309499019850313
    PURPOSE: Expandable endoprosthesis allows limb salvage in children with an option to leading a better life. However, the revision rate and implant-related complications impose as a limitation in the skeletal immature. This study investigates the functional outcomes and complications related to expandable endoprosthesis in our centre.

    MATERIALS AND METHODS: Twenty surviving patients with expandable endoprosthesis from 2006 till 2015 were scored using Musculoskeletal Tumour Society (MSTS) outcomes instrument and reviewed retrospectively for range of motion of respected joints, limb length discrepancy, number of surgeries performed, complications and oncological outcomes. Patients with less than 2 years of follow-up were excluded from this study.

    RESULTS: Forty-five percentage patients reached skeletal maturity with initial growing endoprosthesis and 25% of patients were revised to adult modular prosthesis. One hundred fifty-seven surgeries were performed over the 9-year period. The average MSTS score was 90.83%. The mortality rate was 10% within 5 years due to advanced disease. Infection and implant failure rate was 15% each. The event-free survival was 50% and overall survival rate was 90%.

    CONCLUSION: There is no single best option for reconstruction in skeletally immature. This study demonstrates a favourable functional and survival outcome of paediatric patients with expandable endoprosthesis. The excellent MSTS functional scores reflect that patients were satisfied and adjusted well to activities of daily living following surgery despite the complications.

    Matched MeSH terms: Prosthesis Design
  17. Windecker S, Latib A, Kedhi E, Kirtane AJ, Kandzari DE, Mehran R, et al.
    N Engl J Med, 2020 03 26;382(13):1208-1218.
    PMID: 32050061 DOI: 10.1056/NEJMoa1910021
    BACKGROUND: Polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited.

    METHODS: In an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority.

    RESULTS: A total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority).

    CONCLUSIONS: Among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.).

    Matched MeSH terms: Prosthesis Design
  18. Colombo A, Chandrasekhar J, Aquino M, Ong TK, Sartori S, Baber U, et al.
    Int J Cardiol, 2019 05 15;283:67-72.
    PMID: 30826192 DOI: 10.1016/j.ijcard.2019.01.053
    BACKGROUND: The COMBO stent (OrbusNeich Medical, Ft. Lauderdale, Florida) is a new-generation bio-engineered drug eluting stent, combining an abluminal coating of a bioabsorbable polymer matrix for sustained release of sirolimus and luminal anti-CD34 coating for endothelial progenitor cell capture and rapid endothelialization.

    METHODS: The Multinational Abluminal Sirolimus Coated BiO-Engineered StenT (MASCOT) registry was a prospective post-marketing study conducted from June 2014-May 2017 across 60 centers globally. Patients were eligible if COMBO stent implantation was attempted, and they received dual antiplatelet therapy (DAPT) per local guidelines. Follow-up was conducted by trained research staff at 1, 6 and 12 months by phone or clinic visit to capture clinical events and DAPT cessation events. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, non-fatal myocardial infarction not clearly attributable to a non-target vessel, or ischemia-driven target lesion revascularization.

    RESULTS: A total of 2614 patients were enrolled over the study period with 96.7% completion of 1-year follow-up. The mean age of enrolled patients was 62.9 ± 11.2 years and 23.0% were female. Diabetes mellitus was present at baseline in 33.5%. A total of 56.1% patients underwent PCI for acute coronary syndrome (ACS). The 1-year primary endpoint of TLF occurred in 3.4% patients (n = 88). Definite stent thrombosis occurred in 0.5% patients (n = 12).

    CONCLUSION: The MASCOT post marketing registry provides comprehensive safety and efficacy outcomes following contemporary PCI using the novel COMBO stent in an all-comer population. This platform is associated with low rates of 1-year TLF and ST. CLINICALTRIALS.

    GOV IDENTIFIER: NCT02183454.

    Matched MeSH terms: Prosthesis Design