OBJECTIVE: The purpose of this study was to sense atrial contractions from the Micra ACC signal and provide AV synchronous pacing.
METHODS: The Micra Accelerometer Sensor Sub-Study (MASS) and MASS2 early feasibility studies showed intracardiac accelerations related to atrial contraction can be measured via ACC in the Micra leadless pacemaker. The Micra Atrial TRacking Using A Ventricular AccELerometer (MARVEL) study was a prospective multicenter study designed to characterize the closed-loop performance of an AV synchronous algorithm downloaded into previously implanted Micra devices. Atrioventricular synchrony (AVS) was measured during 30 minutes of rest and during VVI pacing. AVS was defined as a P wave visible on surface ECG followed by a ventricular event <300 ms.
RESULTS: A total of 64 patients completed the MARVEL study procedure at 12 centers in 9 countries. Patients were implanted with a Micra for a median of 6.0 months (range 0-41.4). High-degree AV block was present in 33 patients, whereas 31 had predominantly intrinsic conduction during the study. Average AVS during AV algorithm pacing was 87.0% (95% confidence interval 81.8%-90.9%), 80.0% in high-degree block patients and 94.4% in patients with intrinsic conduction. AVS was significantly greater (P
METHODS: We identified all of our endomyocardial biopsyproven cardiac amyloidosis patients from January 2010 to January 2018 and reviewed their medical records. All patients echocardiographic and ECG findings reviewed and analysed comparing to basic mean population value.
RESULTS: In total there are 13 biopsy-proven cardiac amyloidosis patients. All of the biopsies shows light chain (AL) amyloid. Majority of the patients (8, 61.5%) is male, and most of our patients (8, 61.5%) is Chinese. All seven patients on whom we performed deformation imaging have apical sparing pattern on longitudinal strain echocardiogram. Mean ejection fraction is 49.3%, (SD=7.9). All patients have concentric left ventricular hypertrophy and right ventricular hypertrophy. Diastolic dysfunction was present in all of our patients with nine out of 13 patients (69.2%) having restrictive filling patterns (E/A ≥2.0 E/e' ≥15). On electrocardiogram, 12 (92%) patients have prolonged PR interval (median 200ms, IQR 76.50ms) and 9 (69.2%) patients have pseudoinfarct pattern.
CONCLUSION: Echocardiography plays an important role in diagnosing cardiac amyloidosis. The findings of concentric left ventricular hypertrophy with preserved ejection fraction without increased in loading condition should alert the clinician towards its possibility. This is further supported by right ventricular hypertrophy and particularly longitudinal strain imaging showing apical sparing pattern.
Case presentation: 50-year-old male had his chemoport inserted for adjuvant chemotherapy 3 years ago. During the removal, remaining half of the distal catheter was not found. There was no difficulties during the removal. Chest xray revealed that the fractured catheter had embolized to the right ventricle. Further history taking, he did experienced occasional palpitation and chest discomfort for the past six months. Electrocardiogram and cardiac enzymes were normal. Urgent removal of the fractured catheter via the percutaneous endovascular approach, under fluoroscopic guidance by an experience interventional radiologist was done. The procedure was successful without any complication. Patient made an uneventful recovery. He was discharged the following day, and was well during his 3rd month follow up.
Conclusion: Early detection and preventive measures can be done to prevent pinch-off syndrome. Unrecognized POS can result in fatal complications such as cardiac arrhythmia and septic embolization. Retrieval via the percutaneous endovascular approach provide excellent outcome in the case of embolized fractured catheter.