Displaying publications 141 - 142 of 142 in total

Abstract:
Sort:
  1. Tenekecioglu E, Serruys PW, Onuma Y, Costa R, Chamié D, Sotomi Y, et al.
    JACC Cardiovasc Interv, 2017 06 12;10(11):1115-1130.
    PMID: 28527768 DOI: 10.1016/j.jcin.2017.03.015
    OBJECTIVES: The primary objective of this study was to evaluate the safety and effectiveness of the Mirage (Manli Cardiology, Singapore) bioresorbable microfiber sirolimus-eluting scaffold compared with the Absorb (Abbott Vascular, Santa Clara, California) bioresorbable vascular scaffold in the treatment of stenotic target lesions located in native coronary arteries, ranging from ≥2.25 to ≤4.0 mm in diameter. Secondary objectives were to establish the medium-term safety, effectiveness, and performance of the Mirage device.

    BACKGROUND: The current generation of bioresorbable scaffolds has several limitations, such as thick square struts with large footprints that preclude their deep embedment into the vessel wall, resulting in protrusion into the lumen with microdisturbance of flow. The Mirage sirolimus-eluting bioresorbable microfiber scaffold is designed to address these concerns.

    METHODS: In this prospective, single-blind trial, 60 patients were randomly allocated in a 1:1 ratio to treatment with a Mirage sirolimus-eluting bioresorbable microfiber scaffold or an Absorb bioresorbable vascular scaffold. The clinical endpoints were assessed at 30 days and at 6 and 12 months. In-device angiographic late loss at 12 months was quantified. Secondary optical coherence tomographic endpoints were assessed post-scaffold implantation at 6 and 12 months.

    RESULTS: Median angiographic post-procedural in-scaffold minimal luminal diameters of the Mirage and Absorb devices were 2.38 mm (interquartile range [IQR]: 2.06 to 2.62 mm) and 2.55 mm (IQR: 2.26 to 2.71 mm), respectively; the effect size (d) was -0.29. At 12 months, median angiographic in-scaffold minimal luminal diameters of the Mirage and Absorb devices were not statistically different (1.90 mm [IQR: 1.57 to 2.31 mm] vs. 2.29 mm [IQR: 1.74 to 2.51 mm], d = -0.36). At 12-month follow-up, median in-scaffold late luminal loss with the Mirage and Absorb devices was 0.37 mm (IQR: 0.08 to 0.72 mm) and 0.23 mm (IQR: 0.15 to 0.37 mm), respectively (d = 0.20). On optical coherence tomography, post-procedural diameter stenosis with the Mirage was 11.2 ± 7.1%, which increased to 27.4 ± 12.4% at 6 months and remained stable (31.8 ± 12.9%) at 1 year, whereas the post-procedural optical coherence tomographic diameter stenosis with the Absorb was 8.4 ± 6.6%, which increased to 16.6 ± 8.9% and remained stable (21.2 ± 9.9%) at 1-year follow-up (Mirage vs. Absorb: dpost-procedure = 0.41, d6 months = 1.00, d12 months = 0.92). Angiographic median in-scaffold diameter stenosis was significantly different between study groups at 12 months (28.6% [IQR: 21.0% to 40.7%] for the Mirage, 18.2% [IQR: 13.1% to 31.6%] for the Absorb, d = 0.39). Device- and patient-oriented composite endpoints were comparable between the 2 study groups.

    CONCLUSIONS: At 12 months, angiographic in-scaffold late loss was not statistically different between the Mirage and Absorb devices, although diameter stenosis on angiography and on optical coherence tomography was significantly higher with the Mirage than with the Absorb. The technique of implantation was suboptimal for both devices, and future trials should incorporate optical coherence tomographic guidance to allow optimal implantation and appropriate assessment of the new technology, considering the novel mechanical properties of the Mirage.

    Matched MeSH terms: Single-Blind Method
  2. Teng KT, Chang LF, Vethakkan SR, Nesaretnam K, Sanders TAB
    Clin Nutr, 2017 10;36(5):1250-1258.
    PMID: 27642057 DOI: 10.1016/j.clnu.2016.08.026
    BACKGROUND & AIMS: Modification of the amount and type of dietary fat has diverse effects on cardiovascular risk.

    METHODS: We recruited 54 abdominally obese subjects to participate in a prospective cross-over design, single-blind trial comparing isocaloric 2000 kcal MUFA or carbohydrate-enriched diet with SFA-enriched diet (control). The control diet consisted of 15E% protein, 53E% carbohydrate and 32E% fat (12E% SFA, 13E% MUFA). A total of ∼7E% of MUFA or refined carbohydrate was exchanged with SFA in the MUFA-rich and carbohydrate-rich diets respectively for 6-weeks. Blood samples were collected at fasting upon trial commencement and at week-5 and 6 of each dietary-intervention phase to measure levels of cytokines (IL-6, IL-1β), C-reactive protein (CRP), thrombogenic markers (E-selectin, PAI-1, D-dimer) and lipid subfractions. Radial pulse wave analysis and a 6-h postprandial mixed meal challenge were carried out at week-6 of each dietary intervention. Blood samples were collected at fasting, 15 and 30 min and hourly intervals thereafter till 6 h after a mixed meal challenge (muffin and milkshake) with SFA or MUFA (872.5 kcal, 50 g fat, 88 g carbohydrates) or CARB (881.3 kcal, 20 g fat, 158 g carbohydrates)- enrichment corresponding to the background diets.

    RESULTS: No significant differences in fasting inflammatory and thrombogenic factors were noted between diets (P > 0.05). CARB meal was found to increase plasma IL-6 whereas MUFA meal elevated plasma D-dimer postprandially compared with SAFA meal (P 

    Matched MeSH terms: Single-Blind Method
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links