Materials and Methods: The odorant descriptors and distractors of the original version of Sniffin' Sticks were translated into Malay language. It was then tested for familiarity and identifiability in 30 normosmic subjects. The descriptors were replaced until the familiarity of all descriptors and identification rates of odorants achieved ≥ 70%. The validity of the new cultural-adapted version was tested in 60 hypo-anosmic subjects and 60 normosmic subjects with Student t-test. The test-retest reliability was evaluated after two weeks with interclass correlation.
Results: Two odorant descriptors and nine distractors achieved familiarity <70% (13.3% - 66.7%) and were replaced. Another three culturally inappropriate distractors were also replaced. The mean score among the healthy subjects was significantly higher than the subject with smell dysfunction [13.7 (1.12) and 7.3 (3.42); t = 7.24 (df = 34.23), P<0.001]. The coefficient of correlation (r) between test and retest scores was 0.93 (P<0.001).
Conclusion: The cultural adapted Malaysian version of Sniffin' Sticks smell identification test is valid and has high test-retest reliability. This is the first smell identification test validated in Malaysia. It is effective for evaluation of olfactory function in local population.
OBJECTIVES: This study aims to develop a highly accurate, portable FMD and to demonstrate real-time monitoring of force applied by health professionals during JMT without altering its execution.
METHODS: The FMD was constructed using the FlexiForce sensor, potential divider, ATmega 328 microcontroller, custom-written software, and liquid crystal display. The calibration, accuracy, and cyclic repeatability of the FMD were tested from 0 to 90 N applied load with a gold standard universal testing machine. For practical demonstration, the FMD was tested for monitoring applied force by a physiotherapist while performing Maitland's grade I to IV over the 6th cervical vertebra among 30 healthy subjects.
RESULTS: The obtained Bland-Altman plot limits agreement for accuracy, and cyclic repeatability was -1.57 N to 1.22 N, and -1.26 N to 1.26 N, respectively with standard deviation and standard error of the mean values of 3.77% and 0.73% and 2.15% and 0.23%, respectively. The test-retest reliability of the FMD tested by the same researcher at an interval of one week showed an excellent intra-class correlation coefficient of r= 1.00. The obtained force readings for grade I to IV among 30 subjects ranged from 10.33 N to 45.24 N.
CONCLUSIONS: Appreciable performance of the developed FMD suggested that it may be useful to monitor force applied by clinicians during JMT among neck pain subjects and is a useful educational tool for academicians to teach mobilization skills.
DESIGN: Cross-sectional.
METHODS: Study was conducted among Iranian medical sciences students from April to May 2020. A total of 660 students participated in the online self-administrated questionnaire. Construct validity, convergent and divergent validity, and reliability of P-BMPN were evaluated.
RESULTS: The Exploratory factor analysis showed that the Persian version of the BMPN has 17 items with four factors: dissatisfaction, autonomy Satisfaction, relatedness satisfaction and competence satisfaction that explained 40.17% of the total variance. Based on confirmatory factor analysis, all goodness-of-fit indices confirmed the model fit.