Participants: This was a retrospective study involving premature infants with gestational age less than 32 weeks treated from September 2016 to March 2019 in Hospital Universiti Sains Malaysia. Clinical diagnosis was made based on Early Treatment Retinopathy of Prematurity study. Participants' weekly weight gain since birth was entered in the website (http://winrop.com), along with date of birth, gestational age and final clinical examination outcome. WINROP software signals an alarm if an infant is at high risk of developing ROP requiring treatment during weight data entry. By using the alarm status, the sensitivity and specificity of this algorithm for predicting ROP requiring treatment were obtained.
Results: Ninety-two infants were included in this study. An alarm was detected in 67 infants (72.8%). There were a total of 53 infants (54.6%) with no ROP, 15 (16.3%) of whom developed stage 1 ROP, 10 (10.8%) who developed stage 2 ROP and 14 infants (15.2%) who developed stage 3 ROP. In our study, WINROP sensitivity was 95.2% and specificity was 33.8%.
Conclusion: WINROP is recommended as an initial screening tool for premature infants at risk of developing treatment-requiring ROP in Malaysia. It may help to alert clinicians managing severely ill infants when clinical examinations are less possible.
OBJECTIVES: To assess the effects of reflective materials in combination with phototherapy compared with phototherapy alone for unconjugated hyperbilirubinaemia in neonates.
SEARCH METHODS: We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL; 2019, Issue 11), in the Cochrane Library; Ovid MEDLINE(R) and Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Daily and Versions(R); and the Cumulative Index of Nursing and Allied Health Literature (CINAHL), on 1 November 2019. We also searched clinical trials databases and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials.
SELECTION CRITERIA: We included randomised and quasi-randomised controlled trials if the participants, who were term or preterm infants, received phototherapy with curtains made of reflective materials of any type in the treatment arm, and if those in the comparison arm received similar phototherapy without curtains or other intensified phototherapy, such as a double bank of lights.
DATA COLLECTION AND ANALYSIS: We used standard methodological procedures expected by Cochrane. We used the GRADE approach to assess the certainty of evidence.
MAIN RESULTS: Of 15 studies identified, we included 12 (1288 babies) in the review - 11 comparing phototherapy with reflective materials and phototherapy alone, and one comparing a single phototherapy light bank with reflective materials with double phototherapy. All reflective materials consisted of curtains on three or four sides of the cot and were made of white plastic (five studies), white linen (two studies), or aluminium (three studies); materials were not specified in two studies. Only 11 studies (10 comparing reflective materials versus none and one comparing reflective curtains and a single bank of lights with a double (above and below) phototherapy unit) provided sufficient data to be included in the meta-analysis. Two excluded studies used the reflective materials in a way that did not meet our inclusion criteria, and we excluded one study because it compared four different phototherapy interventions not including reflective materials. The risk of bias of included studies was generally low, but all studies had high risk of performance bias due to lack of blinding of the intervention. Three studies (281 participants) reported a decline in serum bilirubin (SB) (μmol/L) at four to eight hours (mean difference (MD) -14.61, 95% confidence interval (CI) -19.80 to -9.42; I² = 57%; moderate-certainty evidence). Nine studies (893 participants) reported a decline in SB over 24 hours and showed a faster decline in SB in the intervention group, but heterogeneity (I² = 97%) was too substantial to permit a meaningful estimate of the actual effect size (very low-certainty evidence). Subgroup analysis by type of reflective material used did not explain the heterogeneity. Exchange transfusion was reported by two studies; both reported none in either group. Four studies (466 participants) reported the mean duration of phototherapy, and in each of these studies, it was reduced in the intervention group but there was substantial heterogeneity (I² = 88%), precluding meaningful meta-analysis of data. The only two studies that reported the mean duration of hospital stay in hours showed a meaningful reduction (MD -41.08, 95% CI -45.92 to -36.25; I² = 0; moderate-certainty evidence). No studies reported costs of the intervention, parental or medical staff satisfaction, breastfeeding outcomes, or neurodevelopmental follow-up. The only study that compared use of curtains with double phototherapy reported similar results for both groups. Studies that monitored adverse events did not report increased adverse events related to the use of curtains, including acute life-threatening events, but other rarer side effects could not be excluded.
AUTHORS' CONCLUSIONS: Moderate-certainty evidence shows that the use of reflective curtains during phototherapy may result in greater decline in SB. Very low-certainty evidence suggests that the duration of phototherapy is reduced, and moderate-certainty evidence shows that the duration of hospital stay is also reduced. Available evidence does not show any increase in adverse events, but further studies are needed.
METHODS: We performed a systematic literature search in PubMed, Embase, CINAHL and CENTRAL from inception to 30 June 2016 to identify studies investigating the use of early caffeine therapy (initiated at less than 3 days of life) in preterm infants. Effect estimates were combined using random-effects meta-analysis. The primary outcomes for this study were bronchopulmonary dysplasia and mortality.
RESULTS: The initial search found 4066 citations, of which 14 studies enrolling a total of 64 438 participants were included. The time of initiation of early caffeine therapy varied from the first 2 h to 3 days postnatal. Early caffeine therapy reduced the risk of bronchopulmonary dysplasia in both cohort studies (RR: 0.80, 95% CI: 0.66 to 0.96) and randomized controlled trials (RR: 0.67, 95% CI: 0.56 to 0.81). In cohort studies, neonates treated early with caffeine also showed decreased risks of patent ductus arteriosus, brain injury, retinopathy of prematurity and postnatal steroid use. However, the mortality rate was increased.
CONCLUSIONS: The findings suggest that early caffeine therapy is associated with reduced incidence of bronchopulmonary dysplasia and may help decrease the burden of morbidities in preterm infants.
OBJECTIVE: To examine the association between enteral supplementation with high-dose DHA during the neonatal period and the risk of BPD in preterm infants born at less than 29 weeks' gestation.
DATA SOURCES: PubMed, Embase, Web of Science, Cochrane Central Register of Controlled Trials, medRxiv, and ClinicalTrials.gov were searched from inception to August 1, 2022, for eligible articles with no language restrictions.
STUDY SELECTION: Randomized clinical trials (RCTs) were eligible for inclusion (1) if their interventions involved direct administration of a minimum DHA supplementation of 40 mg/kg/d or breast milk or formula feeding of at least 0.4% of total fatty acids, and (2) if they reported data on either BPD, death, BPD severity, or a combined outcome of BPD and death.
DATA EXTRACTION AND SYNTHESIS: Two investigators completed independent review of titles and abstracts, full text screening, data extraction, and quality assessment using the Cochrane Risk of Bias 2.0. Risk ratios (RRs) with 95% CIs were pooled using random-effect meta-analyses.
MAIN OUTCOMES AND MEASURES: Primary outcome was BPD using trial-specific definitions, which was further stratified for RCTs that used a more stringent BPD definition based on systematic pulse oximetry assessment at 36 weeks' postmenstrual age. Other outcomes were BPD, death, BPD severity, or combined BPD and death.
RESULTS: Among the 2760 studies screened, 4 RCTs were included, which involved 2304 infants (1223 boys [53.1%]; mean [SD] gestational age, 26.5 [1.6] weeks). Enteral supplementation with high-dose DHA was associated with neither BPD (4 studies [n = 2186 infants]; RR, 1.07 [95% CI, 0.86-1.34]; P = .53; I2 = 72%) nor BPD or death (4 studies [n = 2299 infants]; RR, 1.04 [95% CI, 0.91-1.18]; P = .59; I2 = 61%). However, an inverse association with BPD was found in RCTs that used a more stringent BPD definition (2 studies [n = 1686 infants]; RR, 1.20 [95% CI, 1.01-1.42]; P = .04; I2 = 48%). Additionally, DHA was inversely associated with moderate-to-severe BPD (3 studies [n = 1892 infants]; RR, 1.16 [95% CI, 1.04-1.29]; P = .008; I2 = 0%).
CONCLUSIONS AND RELEVANCE: Results of this study showed that enteral supplementation with high-dose DHA in the neonatal period was not associated overall with BPD, but an inverse association was found in the included RCTs that used a more stringent BPD definition. These findings suggest that high-dose DHA supplementation should not be recommended to prevent BPD in very preterm infants.
OBJECTIVES: 1. To assess the effects of CPAP on AoP in preterm infants (this may be compared to supportive care or mechanical ventilation). 2. To assess the effects of different CPAP delivery systems on AoP in preterm infants.
SEARCH METHODS: Searches were conducted in September 2022 in the following databases: Cochrane Library, MEDLINE, Embase, and CINAHL. We also searched clinical trial registries and the reference lists of studies selected for inclusion.
SELECTION CRITERIA: We included all randomised and quasi-randomised controlled trials (RCTs) in which researchers determined that CPAP was necessary for AoP in preterm infants (born before 37 weeks). Cross-over studies were also included, provided sufficient data were available for analysis.
DATA COLLECTION AND ANALYSIS: We used the standard methods of Cochrane and Cochrane Neonatal, including independent assessment of risk of bias and extraction of data by at least two review authors. Discrepancies were resolved by involvement of a third author. We used the GRADE approach to assess the certainty of evidence for the following outcomes: 1) failed CPAP; 2) apnoea; 3) adverse effects of CPAP.
MAIN RESULTS: We included four single-centre trials conducted in Malaysia, Spain, Germany, and North America, involving 138 infants with a mean/median gestation of 26 to 28 weeks. Two studies were parallel-group RCTs and two were cross-over trials. None of the studies compared CPAP with supportive care. All trials compared one form of CPAP with another. Two compared a variable flow device with ventilator CPAP, one compared two different variable flow devices, and one compared a variable flow device with bubble CPAP. Interventions were administered for periods ranging between six and 48 hours, with pressures between 4 and 6 cm H2O. We assessed all trials as having a high risk of bias for blinding of participants and personnel, and two studies for blinding of outcome assessors. We found a high risk of a carry-over effect in two studies where the washout period was not adequately described, and a high risk of bias in a study that appeared to use an analysis method not generally accepted for cross-over studies. Comparison 1. CPAP and supportive care compared to supportive care alone We did not identify any study for inclusion in this comparison. Comparison 2. CPAP delivered by different types of devices 2a. Variable flow compared to ventilator CPAP Two studies were included in this comparison. We are very uncertain whether there is any difference in the incidence of failed CPAP, defined as the need for mechanical ventilation (risk ratio (RR) 0.16, 95% confidence interval (CI) 0.01 to 2.90; 1 study, 26 participants; very low-certainty). We are very uncertain whether there is any difference in the frequency of apnoea events (mean difference (MD) per four-hour interval -0.10, 95% CI -1.30 to 1.10; 1 study, 26 participants; very low-certainty). We are uncertain whether there is any difference in adverse events. Neurodevelopmental outcomes were not reported. 2b. Variable flow compared to bubble CPAP We included one study in this comparison, but it did not report our pre-specified outcomes. 2c. Infant Flow variable flow CPAP compared to Medijet variable flow CPAP We are very uncertain whether there is any difference in the incidence of failed CPAP (RR 2.62, 95% CI 0.91 to 7.53; 1 study, 80 participants; very low-certainty). The frequency of apnoea was not reported, and we do not know whether there is any difference in adverse events. Neurodevelopmental outcomes were not reported. Comparison 3. CPAP compared to mechanical ventilation We did not identify any studies for inclusion in this comparison.
AUTHORS' CONCLUSIONS: Due to the limited available evidence, we are very uncertain whether any CPAP device is more effective than other forms of supportive care, other CPAP devices, or mechanical ventilation for the prevention and treatment of AoP. The devices used in these studies included two types of variable flow CPAP device: bubble CPAP and ventilator CPAP. For each comparison, data were only available from a single study. There are theoretical reasons why these devices might have different effects on AoP, therefore further trials are indicated.
OBJECTIVES: To determine the effect of continuous distending pressure in the form of CPAP on the need for IPPV and associated morbidity in spontaneously breathing preterm infants with respiratory distress.
SEARCH METHODS: We used the standard strategy of Cochrane Neonatal to search CENTRAL (2020, Issue 6); Ovid MEDLINE and Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Daily and Versions; and CINAHL on 30 June 2020. We also searched clinical trials databases and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials.
SELECTION CRITERIA: All randomised or quasi-randomised trials of preterm infants with respiratory distress were eligible. Interventions were CPAP by mask, nasal prong, nasopharyngeal tube or endotracheal tube, compared with spontaneous breathing with supplemental oxygen as necessary.
DATA COLLECTION AND ANALYSIS: We used standard methods of Cochrane and its Neonatal Review Group, including independent assessment of risk of bias and extraction of data by two review authors. We used the GRADE approach to assess the certainty of evidence. Subgroup analyses were planned on the basis of birth weight (greater than or less than 1000 g or 1500 g), gestational age (groups divided at about 28 weeks and 32 weeks), timing of application (early versus late in the course of respiratory distress), pressure applied (high versus low) and trial setting (tertiary compared with non-tertiary hospitals; high income compared with low income) MAIN RESULTS: We included five studies involving 322 infants; two studies used face mask CPAP, two studies used nasal CPAP and one study used endotracheal CPAP and continuing negative pressure for a small number of less ill babies. For this update, we included one new trial. CPAP was associated with lower risk of treatment failure (death or use of assisted ventilation) (typical risk ratio (RR) 0.64, 95% confidence interval (CI) 0.50 to 0.82; typical risk difference (RD) -0.19, 95% CI -0.28 to -0.09; number needed to treat for an additional beneficial outcome (NNTB) 6, 95% CI 4 to 11; I2 = 50%; 5 studies, 322 infants; very low-certainty evidence), lower use of ventilatory assistance (typical RR 0.72, 95% CI 0.54 to 0.96; typical RD -0.13, 95% CI -0.25 to -0.02; NNTB 8, 95% CI 4 to 50; I2 = 55%; very low-certainty evidence) and lower overall mortality (typical RR 0.53, 95% CI 0.34 to 0.83; typical RD -0.11, 95% CI -0.18 to -0.04; NNTB 9, 95% CI 2 to 13; I2 = 0%; 5 studies, 322 infants; moderate-certainty evidence). CPAP was associated with increased risk of pneumothorax (typical RR 2.48, 95% CI 1.16 to 5.30; typical RD 0.09, 95% CI 0.02 to 0.16; number needed to treat for an additional harmful outcome (NNTH) 11, 95% CI 7 to 50; I2 = 0%; 4 studies, 274 infants; low-certainty evidence). There was no evidence of a difference in bronchopulmonary dysplasia, defined as oxygen dependency at 28 days (RR 1.04, 95% CI 0.35 to 3.13; I2 = 0%; 2 studies, 209 infants; very low-certainty evidence). The trials did not report use of surfactant, intraventricular haemorrhage, retinopathy of prematurity, necrotising enterocolitis and neurodevelopment outcomes in childhood.
AUTHORS' CONCLUSIONS: In preterm infants with respiratory distress, the application of CPAP is associated with reduced respiratory failure, use of mechanical ventilation and mortality and an increased rate of pneumothorax compared to spontaneous breathing with supplemental oxygen as necessary. Three out of five of these trials were conducted in the 1970s. Therefore, the applicability of these results to current practice is unclear. Further studies in resource-poor settings should be considered and research to determine the most appropriate pressure level needs to be considered.