Displaying publications 101 - 120 of 136 in total

Abstract:
Sort:
  1. Gholizadeh H, Osman NA, Kamyab M, Eshraghi A, Abas WA, Azam MN
    Clin Biomech (Bristol, Avon), 2012 Jan;27(1):34-9.
    PMID: 21794965 DOI: 10.1016/j.clinbiomech.2011.07.004
    The method of attachment of prosthesis to the residual limb (suspension) and socket fitting is a critical issue in the process of providing an amputee with prosthesis. Different suspension methods try to minimize the pistoning movement inside the socket. The Seal-In(®) X5 and Dermo(®) Liner by Ossur are new suspension liners that intend to reduce pistoning between the socket and liner. Since the effects of these new liners on suspension are unclear, the objective of this study was to compare the pistoning effect of Seal-In(®) X5 and Dermo(®) Liner by using Vicon Motion System.
    Matched MeSH terms: Tibia/physiopathology*
  2. Alfaqeh H, Norhamdan MY, Chua KH, Chen HC, Aminuddin BS, Ruszymah BH
    Med J Malaysia, 2008 Jul;63 Suppl A:37-8.
    PMID: 19024972
    This study was to determine if autologous bone marrow mesenchymal stem cells (BMSCs) cultured in chondrogenic medium could repair surgically induced osteoarthritis. Sheep BMSCs were cultured in medium containing 5ng/ml TGFbeta3 + 50ng/ml IGF-1 for three weeks. The cultured cells were then suspended at density of 2x10(6) cell/ml and injected intraarticularly into the osteoarthritic knee joint. After six weeks, the distal head of the femur and the proximal tibial plateau were removed and stained with H&E. The results indicated that knee joints treated with autologous BMSCs cultured in chondrogenic medium showed clear evidence of articular cartilage regeneration in comparison with other groups.
    Matched MeSH terms: Tibia/pathology
  3. Lan GQ, Abdullah N, Jalaludin S, Ho YW
    Poult Sci, 2002 Oct;81(10):1522-32.
    PMID: 12412919
    We evaluated the efficacy of supplementation of active Mitsuokella jalaludinii culture (AMJC) on the growth performance, nutrient use, and mineral concentrations in tibia bone and plasma of broiler chickens fed corn-soybean meal diets. Dietary treatments included low-nonphytate P (NPP) feed (containing 0.24% and 0.232% NPP for chicks from 1 to 21 and 22 to 42 d of age, respectively), low-NPP feed added with different levels of AMJC (equivalent to 250, 500, 750, and 1,000 U phytase/kg of feed), and normal-NPP feed (containing 0.46 and 0.354% NPP for chicks from 1 to 21 and 22 to 42 d of age, respectively). Supplementation of AMJC to low-NPP feed increased (P < 0.05) weight gain and feed intake and decreased (P < 0.05) feed:gain ratio of chickens during the whole experiment (Days 1 to 42). Supplementation of AMJC increased (P < 0.05) the AME value, digestibility of DM and CP, and retention of P, Ca, and Cu. Mn retention in broilers was only increased (P < 0.05) by AMJC supplementation from 18 to 20 d of age, and Zn retention was improved (P < 0.05) only at a high level of AMJC (equivalent to 1,000 U phytase/kg of feed) supplementation. Chicks fed low-NPP feed added with AMJC had similar tibia ash percentages as those fed the normal-NPP diet. Generally, supplementing AMJC to low-NPP feed increased (P < 0.05) Ca, decreased significantly (P < 0.05) Mn and Cu, but did not affect Zn and P concentrations in tibia ash. Supplementing AMJC also increased (P < 0.05) plasma P but had no effect on plasma Ca or Mn. Plasma Zn concentration was increased only when a high level of AMJC (equivalent to 1,000 U phytase/kg of feed) was used. In conclusion, AMJC supplementation to low-NPP feed improved growth performance; AME value; digestibility of CP and DM; use of Ca, P, and Cu; and bone mineralization.
    Matched MeSH terms: Tibia/chemistry
  4. Saw A, Phang ZH, Alrasheed MK, Gunalan R, Albaker MZ, Shanmugam R
    J Orthop Surg (Hong Kong), 2019 9 19;27(3):2309499019873987.
    PMID: 31530084 DOI: 10.1177/2309499019873987
    PURPOSE: Management of Blount disease in adolescents and young adults is complex and associated with high risk of morbidities. Gradual correction with external fixator can minimize soft tissue injury and allow subsequent adjustment in degree of correction. This study investigates the surgical outcome and complication rate of gradual correction of neglected Blount disease through single-level extra-articular corticotomy.

    METHODS: Patients treated for Blount disease using external fixator from 2002 to 2016 were recruited for the study. We used Ilizarov and Taylor Spatial Frame (TSF) external fixator to perform simultaneous correction of all the metaphyseal deformities without elevating the tibia plateau. Surgical outcome was evaluated using mechanical axis deviation (MAD), tibial femoral angle (TFA), and femoral condyle tibial shaft angle (FCTSA).

    RESULTS: A total of 22 patients with 32 tibias have been recruited for the study. The mean MAD improved from 95 ± 51.4 mm to 9.0 ± 37.7 mm (medial to midpoint of the knee), mean TFA improved from 31 ± 15° varus to 2 ± 14° valgus, and mean FCTSA improved from 53 ± 14° to 86 ± 14°. Mean duration of frame application is 9.4 months. Two patients developed pathological fractures over the distracted bones, one developed delayed consolidation and other developed overcorrection.

    CONCLUSIONS: Correction of Blount disease can be achieved by gradual correction using Ilizarov or TSF external fixator with low risk of soft tissue complication. Longer duration of frame application should be considered to reduce the risk of pathological fracture or subsequent deformation of the corrected bone.

    Matched MeSH terms: Tibia/surgery
  5. Kim JE, Won S, Jaffar MSA, Lee JI, Kim TW, Lee YS
    Knee, 2020 Jun;27(3):940-948.
    PMID: 32331827 DOI: 10.1016/j.knee.2020.04.008
    BACKGROUND: Open-wedge high tibial osteotomy (OWHTO) produces three- dimensional (3D) geometric changes. Among them, increased posterior tibial slope (PTS), and altered coronal inclination that induces unintended tibial translation may affect anterior cruciate ligament (ACL) status. The purpose of current study was to evaluate the geometric changes following OWHTO, such as increasing PTS and decreasing tibial subluxation, which may affect the status of ACL.

    METHODS: From April 2014 to December 2015, a total of 72 knees in 64 patients that underwent OWHTO, second-look arthroscopy, and magnetic resonance imaging (MRI) assessment, were enrolled. Preoperative and postoperative coronal and sagittal translation, joint line orientation angle, the distance between medial femoral notch marginal line and medial tibial spine, and PTS were evaluated. ACL status was arthroscopically graded from grade 1 (best) to 4 (worst). The MRI signal of the graft in three portions (proximal, middle, and distal) was graded from grade 1 (best) to 4 (worst).

    RESULTS: High grade (3: partial, and 4: complete rupture) was noted in 28 cases (38.9%) at the second-look arthroscopy compared with 10 cases (13.9%) at index arthroscopy. The MRI signal grade significantly increased at follow up MRI compared with preoperative MRI (P<0.01). An increased signal was commonly noted in the middle and distal portions of the graft.

    CONCLUSIONS: Geometric changes after OWHTO were related to ACL deterioration. The ACL was commonly affected at the middle and distal portions and rarely at the proximal portion. There is a possibility of impingement because of the geometric changes.

    LEVEL OF EVIDENCE: Level IV.

    Matched MeSH terms: Tibia/surgery
  6. Ng CK, Chen JY, Yeh JZY, Ho JPY, Merican AM, Yeo SJ
    J Arthroplasty, 2018 06;33(6):1936-1944.
    PMID: 29395720 DOI: 10.1016/j.arth.2017.12.025
    BACKGROUND: We hypothesized that there is a correlation between the distal femoral rotation and proximal tibial joint line obliquity in nonarthritic knees. This has significance for kinematic knee arthroplasty, in which the target knee alignment desired approximates the knee before disease.

    METHODS: Fifty computed tomography scans of nonarthritic knees were evaluated using three-dimensional image processing software. Four distal femoral rotational axes were determined in the axial plane: the transepicondylar axis (TEA), transcondylar axis (TCA), posterior condylar axis (PCA), and a line perpendicular to Whiteside's anterior-posterior axis. Then, angles were measured relative to the TEA. Tibial joint line obliquity was measured as the angle between the proximal tibial plane and a line perpendicular to the axis of the tibia.

    RESULTS: There was a strong positive correlation between PCA-TEA and tibial joint line obliquity (r = 0.68, P < .001) as well as TCA-TEA and tibial joint line obliquity (r = 0.69, P < .001). In addition, the tibial joint line obliquity and TCA-TEA angles were similar, 3.7° ± 2.2° (mean ± standard deviation) and 3.5° ± 1.7°, respectively (mean difference, 0.2° ± 0.2°; P = .369).

    CONCLUSION: Both PCA-TEA and TCA-TEA strongly correlated with proximal tibial joint line obliquity indicating a relationship between distal femoral rotational geometry and proximal tibial inclination. These findings could imply that the native knee in flexion attempts to balance the collateral ligaments toward a rectangular flexion space. A higher tibial varus inclination is matched with a more internally rotated distal femur relative to the TEA.

    Matched MeSH terms: Tibia/surgery*
  7. Al-Fakih EA, Osman NA, Eshraghi A, Adikan FR
    Sensors (Basel), 2013 Aug 12;13(8):10348-57.
    PMID: 23941909 DOI: 10.3390/s130810348
    This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.
    Matched MeSH terms: Tibia/physiopathology
  8. Muhammad Abdul Jamil MK, Abdul Rashid AH, Ibrahim S
    J Pediatr Orthop B, 2013 May;22(3):207-12.
    PMID: 22182834 DOI: 10.1097/BPB.0b013e32834ecc01
    This preliminary report is on two patients with congenital pseudoarthrosis of the tibia who had a persistent nonunion following intramedullary rodding and bone grafting. We do not advocate repeated surgery to achieve union. When limb length discrepancy becomes greater than 5 cm, we proceeded with an Ilizarov procedure with the primary aim of equalizing limb length rather than achieving union. Healing of the pseudoarthrosis occurred in both patients after lengthening over the intramedullary rod without compression of the nonunion site. We believe that union occurs because of hyperaemia during the lengthening. This approach minimizes the repeated surgeries that are usually needed and thus ensures a more normal childhood without frequent hospitalizations.
    Matched MeSH terms: Tibia/radiography; Tibia/surgery*; Tibial Fractures/etiology; Tibial Fractures/radiography; Tibial Fractures/surgery
  9. Chin KY, Ima-Nirwana S
    Clin Interv Aging, 2014;9:1247-59.
    PMID: 25120355 DOI: 10.2147/CIA.S67016
    BACKGROUND: Previous animal models have demonstrated that tocotrienol is a potential treatment for postmenopausal osteoporosis. This study evaluated the antiosteoporotic effects of annatto-derived tocotrienol (AnTT) using a testosterone-deficient osteoporotic rat model.
    METHODS: Forty rats were divided randomly into baseline, sham, orchidectomized, AnTT, and testosterone groups. The baseline group was euthanized without undergoing any surgical treatment or intervention. The remaining groups underwent orchidectomy, with the exception of the sham group. AnTT 60 mg/kg/day was given orally to the AnTT group, while the testosterone group received testosterone enanthate 7 mg/kg per week intramuscularly for 8 weeks. Structural changes in trabecular bone at the proximal tibia were examined using microcomputed tomography. Structural and dynamic changes at the distal femur were examined using histomorphometric methods. Serum osteocalcin and C-terminal of type 1 collagen crosslinks were measured. Bone-related gene expression in the distal femur was examined.
    RESULTS: There were significant degenerative changes in structural indices in the orchidectomized group (P<0.05), but no significant changes in dynamic indices, bone remodeling markers, or gene expression (P>0.05) when compared with the sham group. The AnTT group showed significant improvement in structural indices at the femur (P<0.05) and significantly increased expression of bone formation genes (P<0.05). Testosterone was more effective than AnTT in preventing degeneration of bone structural indices in the femur and tibia (P<0.05).
    CONCLUSION: AnTT supplementation improves bone health in testosterone-deficient rats by enhancing bone formation. Its potential should be evaluated further by varying the dosage and treatment duration.
    KEYWORDS: bone remodeling; osteoporosis; testosterone; tocotrienol
    Matched MeSH terms: Tibia/radiography
  10. Gholizadeh H, Abu Osman NA, Kamyab M, Eshraghi A, Lúvíksdóttir AG, Wan Abas WA
    Am J Phys Med Rehabil, 2012 Oct;91(10):894-8.
    PMID: 22173083
    The effects of Seal-In X5 and Dermo liner (Össur) on suspension and patient's comfort in lower limb amputees are unclear. In this report, we consider the case of a 51-yr-old woman with bilateral transtibial amputation whose lower limbs were amputated because of peripheral vascular disease. The subject had bony and painful residual limbs, especially at the distal ends. Two prostheses that used Seal-In X5 liners and a pair of prostheses with Dermo liners were fabricated, and the subject wore each for a period of 2 wks. Once the 2 wks had passed, the pistoning within the socket was assessed and the patient was questioned as to her satisfaction with both liners. This study revealed that Seal-In X5 liner decreased the residual limb pain experienced by the patient and that 1-2 mm less pistoning occurred within the socket compared with the Dermo liner. However, the patient needed to put in extra effort for donning and doffing the prosthesis. Despite this, it is clear that the Seal-In X5 liner offers a viable alternative for individuals with transtibial amputations who do not have enough soft tissue around the bone, especially at the end of the residual limb.
    Matched MeSH terms: Tibia/surgery*
  11. Kwan MK, Penafort R, Saw A
    Med J Malaysia, 2004 Dec;59 Suppl F:39-41.
    PMID: 15941159
    Joint stiffness is one of the complications of limb procedure. It developes as a result of failure of knee flexors to lengthen in tandem with the bone, especially when there is inadequate physical therapy to provide active and passive mobilization of the affected joint. We are reporting four patients who developed fixed flexion contracture of their knees during bone lengthening procedure for the tibia with Ilizarov external fixator. Three of them were treated for congenital pseudoarthrosis and one was for fibular hemimelia. None of them were able to visit the physiotherapist even on a weekly basis. A splint was constructed from components of Ilizarov external fixator and applied on to the existing frame to passively extend the affected knee. Patients and their family members were taught to perform this exercise regularly and eventually near complete correction were achieved. With this result, we would like to recommend the use of this "Passive Knee Extension Splint" to avoid knee flexion Contracture during limb lengthening procedures with Ilizarov external fixators.
    Matched MeSH terms: Tibia/surgery*
  12. Imran Y, Zulmi W, Halim AS
    Med J Malaysia, 2004 Dec;59 Suppl F:35-8.
    PMID: 15941158
    Long bone reconstruction using vascularized fibula graft is becoming more popular despite the difficulties and its post-operative complications. We reviewed our early experience dealing with vascularized fibula graft for the management of massive long bone defect. Thirteen patients had undergone long bone reconstruction using vascularized fibula graft. Early complications that had been encountered include superficial wound infection (23%), transient common peroneal nerve palsy (23%), stage 1 bed sore (7.7%), anastomotic venous thrombosis (30.8%), DIVC (15.4%), flap loss and amputation (7.7%), and reactive psychiatric problem (7.7%). The early complications following this procedure are comparable with other major orthopaedic surgery and most of them are minor and treatable. The complication rates are also comparable with similar surgery done elsewhere.
    Matched MeSH terms: Tibia/surgery
  13. Makinejad MD, Abu Osman NA, Abu Bakar Wan Abas W, Bayat M
    Clinics (Sao Paulo), 2013 Sep;68(9):1180-8.
    PMID: 24141832 DOI: 10.6061/clinics/2013(09)02
    This study provides an experimental and finite element analysis of knee-joint structure during extended-knee landing based on the extracted impact force, and it numerically identifies the contact pressure, stress distribution and possibility of bone-to-bone contact when a subject lands from a safe height.
    Matched MeSH terms: Tibia/physiology
  14. Ali S, Osman NA, Razak A, Hussain S, Wan Abas WA
    Eur J Phys Rehabil Med, 2015 Feb;51(1):31-7.
    PMID: 24963603
    Lower limb amputee's are greatly affected in dealing with the environmental barriers such as ramps and stairs and reported high interface pressure between the residual limb and socket/liner. Interface pressure between the residual limb and socket/liner can affect the satisfaction and use of the prosthesis. Until now, little attention has been paid to interface pressure between socket and stump during ramp negotiation and its effect on amputee's satisfaction.
    Matched MeSH terms: Tibia
  15. Faisham W, Azman W, Muzaffar T, Muslim D, Azhar A, Yahya M
    Malays Orthop J, 2012 Nov;6(3):37-9.
    PMID: 25279054 MyJurnal DOI: 10.5704/MOJ.1207.002
    Traumatic hemipelvectomy is an uncommon and life threatening injury. We report a case of a 16-year-old boy involved in a traffic accident who presented with an almost circumferential pelvic wound with wide diastasis of the right sacroiliac joint and symphysis pubis. The injury was associated with complete avulsion of external and internal iliac vessels as well as the femoral and sciatic nerves. He also had ipsilateral open comminuted fractures of the femur and tibia. Emergency debridement and completion of amputation with preservation of the posterior gluteal flap and primary anastomosis of the inferior gluteal vessels to the internal iliac artery stump were performed. A free fillet flap was used to close the massive exposed area.
    Matched MeSH terms: Tibia
  16. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Sævarsson SK, Wan Abas WA, et al.
    J Rehabil Res Dev, 2012;49(9):1321-30.
    PMID: 23408214
    Poor suspension increases slippage of the residual limb inside the socket during ambulation. The main purpose of this article is to evaluate the pistoning at the prosthetic liner-socket interface during gait and assess patients' satisfaction with two different liners. Two prostheses with seal-in and locking liners were fabricated for each of the 10 subjects with transtibial amputation. The Vicon motion system was used to measure the pistoning during gait. The subjects were also asked to complete a Prosthesis Evaluation Questionnaire. The results revealed higher pistoning inside the socket during gait with the locking liner than with the seal-in liner (p < 0.05). The overall satisfaction with the locking liner was higher (p < 0.05) because of the relative ease with which the patients could don and doff the device. As such, pistoning may not be the main factor that determines patients' overall satisfaction with the prosthesis and other factors may also contribute to comfort and satisfaction with prostheses. The article also verifies the feasibility of the Vicon motion system for measuring pistoning during gait.
    Matched MeSH terms: Tibia
  17. Chilmi MZ, Desnantyo AT, Widhiyanto L, Wirashada BC
    Malays Orthop J, 2020 Jul;14(2):145-148.
    PMID: 32983392 DOI: 10.5704/MOJ.2007.025
    In Indonesia, arthrodesis becomes a choice of treatment in the absence of ankle arthroplasty implants for young adults. Arthrodesis on ankle osteoarthritis (OA) often leads to functional impairment. Low tibiofibular osteotomy is an alternative and it has been known to be the preferable option for those in the productive-ages. A 22-year-old male with a previous history of a motorbike accident, operated eight years ago, came with persistent pain on the left ankle that has worsened over the years. Plain radiography with a tibial-ankle surface angle (TAS) of 74o (normally 88o-93o) indicated varus deformity. Osteotomy was performed on distal tibia above the syndesmotic joint, as well as on the middle third of fibula. Open wedge osteotomy of the tibia was corrected until the normal TAS angle was reached by fluoroscopy. Cortical allograft was used to fill the osteotomy gap. Instrumentation was performed using a clover leaf® plate with 6 screws insertion for fixation stability. All results were satisfactory. Twelve weeks post-operatively, the patient was performing activities normally. Four-month post-operative radiological evaluation showed fusion of graft and the angle of TAS of 89°. Post-operative functional assessment using the American Academy of Orthopaedic Surgeon (AAOS) Foot and Ankle Measurement (FAM) questionnaires showed significant improvement (pre 89, post 38).
    Matched MeSH terms: Tibia
  18. Yuce A, Dedeoglu SS, Imren Y, Yerli M, Gurbuz H
    Malays Orthop J, 2020 Nov;14(3):90-97.
    PMID: 33403067 DOI: 10.5704/MOJ.2011.014
    Introduction: The selection of the stage where fibular plate was performed in two-stage surgery of the intra-articular distal tibiofibular fractures with soft tissue injury is still controversial. The aim of the study was to compare the complications, radiological and functional outcomes between the patients who had fibular plate at initial or second phase during surgical management of such fractures.

    Materials and Methods: In this study, medical records of 47 patients who underwent a two-stage surgical procedure for intra-articular distal tibia fractures accompanying soft tissue injury were retrospectively examined. Delta frame was applied in all cases within 24 hours following admission to the emergency department in accordance with AO principles. Those cases where fibular plate was applied during the initial stage and the second stage were classified as Group 1 and Group 2 in order to compare recorded data between the two groups.

    Results: According to the results of the study, there were 25 cases in Group 1 and 22 cases in Group 2 in which fibular plate was applied at the first stage and the second stage, respectively. The mean follow-up was found as 27.7±7.0 months in Group 1 and 28.2±6.2 months in Group 2 (p=0.778). No difference was found between the two groups in terms of the age, sex, hospital stay, the time between two surgical procedures, tibiofibular angle and AOFAS scoring (p>0.05).These two groups were also similar in mechanism of injury, Denise-Weber or AO classification, rates of tibiofibular malalignment on post-operative CT, fibular rotation, intra-articular tibial step-off, tibial varus-valgus duration of union, rate of infection, fibular angulation and the presence of the flap/graft/debridement (p>0.05).

    Conclusion: In conclusion, two-stage surgical procedure in intra-articular distal tibiofibular fractures may be an effective method decreasing soft tissue complications. The timing of the open reduction and internal fixation of the fibula at different stages may not necessarily have an impact on the success of the post-operative tibial reduction, the total duration of surgery, syndesmosis malalignment or soft tissue complications.

    Matched MeSH terms: Tibia; Tibial Fractures
  19. Rushdi I, Che-Ahmad A, Abdul-Ghani K, Mohd-Rus R
    Malays Orthop J, 2020 Nov;14(3):57-65.
    PMID: 33403063 DOI: 10.5704/MOJ.2011.010
    Introduction: Distal tibia fractures are frequently associated with an extensive soft tissue injury which then leads to a higher risk of complications such as infection, non-union and eventually poor overall outcome. The purpose of this study is to measure the outcome of distal tibia fractures treated with internal fixation, external fixator or Ilizarov external fixator(IEF). We aim to propose an algorithm for management of distal tibia fractures by evaluating the treatment options, outcomes and risk factors present.

    Material and Methods: This study is a cross-sectional study of all distal tibia fractures treated surgically in Tengku Ampuan Rahimah Hospital, Klang from 1st January 2016 till 30th June 2018. Patient records were reviewed to analyse the outcomes of surgical treatment and risk factors associated with it.

    Results: Ninety-one patients were included with a mean age of 41.5 years (SD = 16.4). Thirty-nine cases (42.9%) were open fractures. Thirty-eight patients (41.8%) were treated with internal fixation, 27 patients (29.7%) were treated with IEF and 26 patients (28.6%) were treated with an external fixator. Among open fractures cases, no significant finding can be concluded when comparing each surgical option and its outcome, although one option was seen better than the other in a particular outcome. Initial skeletal traction or temporary spanning external fixator in close fractures reduced the risk of mal-alignment (p value=0.001). Internal fixation is seen superior to IEF and external fixator in close fractures in term of articular surface reduction (p value = 0.043) and risk of mal-alignment (p value = 0.007).

    Conclusion: There is no single method of fixation that is ideal for all pilon fractures and suitable for all patients. This proposed algorithm can help surgeons in deciding treatment strategies in the challenging management of distal tibia fractures to reduce associated complications.

    Matched MeSH terms: Tibia; Tibial Fractures
  20. Gupta R, Singhal A, Malhotra A, Soni A, Masih GD, Raghav M
    Malays Orthop J, 2020 Nov;14(3):50-56.
    PMID: 33403062 DOI: 10.5704/MOJ.2011.009
    Introduction: Few authors have addressed risk factors related to an ipsilateral graft rupture and contralateral anterior cruciate ligament (ACL) injury after return to sports (RTS) following primary ACL reconstruction.

    Material and Methods: Patients with ACL re-injury to either knee after successful primary ACLR were included in Group I and those with no further re-injury were included in Group II. Variables including age, gender, side, body mass index (BMI), thigh atrophy, anterior knee laxity difference between both knees measured by KT-1000 arthrometer, mean time of return to sports (RTS), graft type, type of game, mode of injury, Tegner Activity Score, hormone levels, femoral tunnel length (FTL), posterior tibial slope (PTS) and notch width index (NWI) were studied. Binary logistic regression was used to measure the relative association.

    Results: A total of 128 athletes were included with 64 in each group. Mean age in Group I and II were 24.90 and 26.47 years respectively. Mean follow-up of Group I and Group II were 24.5 and 20.11 months respectively. Significant correlation was present between ACL re-injury and following risk factors; PTS of >10º, KT difference of >3.0mm, thigh atrophy of >2.50cm and time to RTS <9.50 months P value <0.05). No correlation was found with age, sex, BMI, type of game, Tegner Activity Score, mode of injury, NWI, size of graft, FTL and hormone levels.

    Conclusion: Possible risk factors include PTS of ≥ 10º, KT difference of ≥ 3.0mm at 1 year follow-up, thigh atrophy of ≥ 2.50cm at 1 year follow-up and RTS <9.5 months after primary ACLR.

    Matched MeSH terms: Tibia
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links