Displaying publications 61 - 80 of 151 in total

Abstract:
Sort:
  1. Vengatesh Rao, Irfan Mohamad
    MyJurnal
    The unilateral nasal symptom should trigger a treating physician to a certain diagnosis. The differential
    diagnosis includes foreign body, rhinolith and tumour. The chronicity of symptom helps a lot with the diagnosis.
    Foreign body for example, tends to present with positive history of insertion, mainly by children or the acute
    symptom of local infection. In the presence of prolonged symptom, rhinolith should be suspected especially when
    the patient presents with pathognomonic nasal obstruction with foul smelly discharge. A referral should be made
    for a nasoendoscopy evaluation whenever a rhinitis-like symptoms remain after a period of medical treatment for
    allergy. We share a case of a missed diagnosis of a rhinolith after six years of symptoms.
    Matched MeSH terms: Foreign Bodies
  2. Khoo PJ, Tay KL, Jamaluddin AA, Gunasaker D
    Ann Med Surg (Lond), 2018 Sep;33:44-46.
    PMID: 30167303 DOI: 10.1016/j.amsu.2018.08.004
    Introduction: We present a case of broken peripheral intravenous catheter/cannula (PIVC), a well-known, underreported complication of PIVC placement. The fractured cannula could have resulted in intravascular foreign body retention, which is usually iatrogenic.

    Presentation of case: In this case, we conceded that both iatrogenic and self-infliction were culpable. The intoxicated, aggressive patient forcefully removed the inserted cannula after repeated attempts by medical personnel to place it. The same cannula was used for multiple attempts. After the location of the fractured catheter was reconfirmed with radiological imaging, venotomy and removal of the foreign body were performed.

    Conclusion: Due to potentially devastating consequences, early detection, adherence to standard operating procedures for peripheral venous access, management of aggressive patients, and meticulous teamwork must be upheld.

    Matched MeSH terms: Foreign Bodies
  3. Andrea, B.K., Safinaz, M.K., Umi Kalthum, M.N., Mushawiahti, M.
    MyJurnal
    Traumatic injury to the eye can occur due to various causes, most of which are avoidable. Here we report three cases of intrastromal corneal foreign bodies (FB) which required surgical removal. Most corneal FBs are removed easily at the slit lamp, however, these cases required surgical intervention due to the mechanism of which the FB penetrated into the stroma. Although the mechanism of injury was similar, with all three cases occurring at high velocity, we observed that the entry and level of penetration differed in each case. In the first case, the corneal FB penetrated the cornea and was embedded in the anterior stroma, whereas in the second case, the FB was embedded in the posterior stroma, but with an intact endothelium. In the third case, the FB caused a full thickness, self-sealed laceration wound but remained embedded in the stroma. Through further evaluation, we noted that several factors contribute towards the severity of the injury, namely, anatomy of the cornea, area affected, shape, size, mass and velocity of the object. We speak in depth about the mechanism of injury and physics associated with these injuries and why the penetration differed in each case.
    Matched MeSH terms: Eye Foreign Bodies
  4. Sinha KC
    Malaya Medical Journal, 1911;9:68-71.
    Matched MeSH terms: Foreign Bodies
  5. Philip R, Imran AG, Dinsuhaimi S, Shahid H
    Med J Malaysia, 2006 Jun;61(2):233-5.
    PMID: 16898319 MyJurnal
    Various complications are associated with the use of indwelling voice prostheses. We present problems faced by a patient with his Voice-Master prosthesis, the ingestion of the prosthesis followed by a potentially fatal aspiration. The Voice-Master is unique in that in can be re-inserted. The safety strap is removed after primary insertion once the prosthesis is secure. However, during re-insertions this safety mechanism is no longer present. Therefore we recommend the placement of a temporary stitch or tie to minimize the risks of ingestion or aspiration of the prosthesis during re-insertions.
    Matched MeSH terms: Foreign Bodies/complications*; Foreign Bodies/surgery
  6. Sharma HS, Sharma S
    J Accid Emerg Med, 1999 Mar;16(2):150-3.
    PMID: 10191459
    Foreign body aspiration is one of the leading causes of accidental death in children. Food items are the most common items aspirated in infants and toddlers, whereas older children are more likely to aspirate non-food items. Laryngeal impaction of a foreign body is very rare as most aspirated foreign bodies pass through the laryngeal inlet and get lodged lower down in the airway. Two rare cases of foreign body aspiration with subglottic impaction in very young children (under 2 years of age) are described. In both the cases subglottic impaction occurred consequent to attempted removal of foreign body by blind finger sweeping. The clinical presentation, investigations, and management of these rare cases are discussed.
    Matched MeSH terms: Foreign Bodies/diagnosis; Foreign Bodies/surgery*
  7. Abdullah BJ, Teong LK, Mahadevan J, Jalaludin A
    J Otolaryngol, 1998 Aug;27(4):190-4.
    PMID: 9711512
    Impacted foreign bodies in the trachea and esophagus are common. In the esophagus, these are usually bones, while for the trachea, it is commonly some form of seed or nut. The incidence of impacted dental prostheses is not highlighted in the literature. They usually have a definite history of ingestion, frequently during trauma, seizures, or sleep. Prompt management in a safe and effective manner is required if significant morbidity, and even mortality, is to be avoided.
    Matched MeSH terms: Foreign Bodies/complications; Foreign Bodies/radiography*
  8. Goh TH, Kuan BB
    Med J Malaysia, 1985 Mar;40(1):44-5.
    PMID: 3831735
    A retained Graefenberg , ring intrauterine. contraceptive device which looked like a fractured Lippes loop on pelvic radiography is presented, and its management outlined.
    Matched MeSH terms: Foreign Bodies/complications; Foreign Bodies/radiography*
  9. Teoh GH, Yow CS
    Med J Malaysia, 1982 Mar;37(1):7-10.
    PMID: 7121351
    A retrospective study of intraocular foreign bodies treated at the University Hospital over 10 years from 1970 - 1979 was carried out. Of the 48 cases reviewed, nine were anterior chamber foreign bodies while the rest were posterior segment foreign bodies. The anterior chamber foreign bodies had better visual prognosis as compared to the posterior segment foreign bodies. Most of the patients were young Chinese males and most of the injuries were due to accidents at work involving the 'hand hammer' (includes other implements used as a hammer).
    Matched MeSH terms: Eye Foreign Bodies/epidemiology*; Eye Foreign Bodies/therapy
  10. Tan PL
    Med J Malaysia, 1980 Sep;35(1):58-60.
    PMID: 7254000
    3 cases of perforating injury with retention of intra-ocular foreign body are presented. Their clinical presentation, management and final visual results are discussed. Despite the generally poor prognosis associated with these injuries, some cases surprisingly have good visual results.
    Matched MeSH terms: Eye Foreign Bodies/complications; Eye Foreign Bodies/therapy*
  11. Liew SK, Fong TS, Teh KK
    J Hand Surg Asian Pac Vol, 2021 Mar;26(1):103-106.
    PMID: 33559570 DOI: 10.1142/S2424835521720048
    Chronic embedded-ring injury is a rare and uncommon presentation. This is also known as "chronic ring erosion" or "embedded ring syndrome" in the literature. Injury of this type has been associated with psychological impairment causing neglect of such injury. We herein describe a case of double embedded rings on the right ring finger in a 30-year-old healthy construction worker. A primary amputation at the metacarpophalangeal joint was performed in view of the chronicity of his condition and associated neurovascular damage. Early removal of ring is of paramount importance in any ring-associated injuries. However, fear of losing a digit has been the reason of delay in seeking medical treatment, which in turn ended up in dire consequences.
    Matched MeSH terms: Foreign Bodies/complications*; Foreign Bodies/surgery
  12. Indudharan R, Ahamad M, Ho TM, Salim R, Htun YN
    Ann Trop Med Parasitol, 1999 Mar;93(2):163-7.
    PMID: 10474641
    Accidental entry of insects and other arthropods is a common aetiology of aural foreign bodies (FB) presenting to accident and emergency departments. A retrospective study revealed that the FB in almost half (148) of 348 cases of aural FB investigated at the Universiti Sains Malaysia Hospital was an arthropod. The most common arthropod encountered was the cockroach, followed by a cattle tick. The high prevalence of tick infestation of the human ear canal (i.e. human otoacariasis) currently appears to be unique to the Malaysian state of Kelantan. The presentation of patients with intra-aural ticks, the methods used to remove the ticks, the complications encountered, and recommendations for an appropriate course of action in such cases are discussed.
    Matched MeSH terms: Foreign Bodies/parasitology*; Foreign Bodies/therapy
  13. Shanmugham MS
    Singapore Med J, 1984 Feb;25(1):52-3.
    PMID: 6463665
    In this paper the incidence of inhaled foreign body in the tracheobronchial tree at the University Hospital Kuala Lumpur, West Malaysia, is reviewed. Children are the usual victims. Food·related substance (peanut) is the most common foreign body, Successful removal of foreign body by bronchoscopy is achieved in the great majority of cases (86%), Prevention can be achieved by educating the parents not to give nuts to children below the age of 3 years.
    Matched MeSH terms: Foreign Bodies/epidemiology*; Foreign Bodies/therapy
  14. Kah TA, Salowi MA, Tagal JM, Thanaraj A, Premsenthil M, Gudom Ia
    Cornea, 2009 Dec;28(10):1164-6.
    PMID: 19770717 DOI: 10.1097/ICO.0b013e31819aa9d9
    To demonstrate the role of ultrasonographic biomicroscopy in diagnosing occult open globe injury.
    Matched MeSH terms: Eye Foreign Bodies/etiology*; Eye Foreign Bodies/physiopathology; Eye Foreign Bodies/surgery; Eye Foreign Bodies/ultrasonography*
  15. Tan YL, Lo TS, Khanuengkitkong S, Dass AK
    Taiwan J Obstet Gynecol, 2013 Sep;52(3):435-6.
    PMID: 24075389 DOI: 10.1016/j.tjog.2013.01.027
    Matched MeSH terms: Foreign Bodies/complications*; Foreign Bodies/diagnosis
  16. Loch A, Singh RV, Abidin IZ, Han CK, Ahmad WA
    J Thorac Oncol, 2011 Jul;6(7):1292.
    PMID: 21847043 DOI: 10.1097/JTO.0b013e31821f9771
    Matched MeSH terms: Foreign Bodies/etiology; Foreign Bodies/therapy*
  17. Vairavan N, Tajunisah I, Subrayan V, Waran V
    Orbit, 2009;28(6):442-3.
    PMID: 19929682 DOI: 10.3109/01676830903103365
    Surgical approaches are becoming increasingly minimally invasive, without compromising either safety or ease. Penetrating ocular foreign bodies has traditionally been approached either by intraocular or supraorbital access. We successfully attempted a minimally invasive approach to remove a retrobulbar foreign body under computer-assisted image guidance in a 19-year-old man involved in an industrial mishap.
    Matched MeSH terms: Eye Foreign Bodies/radiography; Eye Foreign Bodies/surgery*
  18. Tie ST, Wong JL, Kannan SK, Rahman JA
    J Bronchology Interv Pulmonol, 2012 Jul;19(3):246-8.
    PMID: 23207471 DOI: 10.1097/LBR.0b013e31825c3228
    We report a case of a young man who presented with a left-sided pneumothorax after suffering an accidental penetrating injury by a sewing needle to the anterior chest wall. Chest radiograph and the computed tomography of the thorax revealed that the needle was in the pleural cavity and there was an associated pneumothorax. An attempt at retrieval by direct incision failed. The sewing needle was successfully retrieved by a medical pleuroscopy. The patient recovered without any consequences and was discharged home after 24 hours of observation.
    Matched MeSH terms: Foreign Bodies/radiography; Foreign Bodies/surgery*
  19. Hon SK, Izam TM, Koay CB, Razi A
    Med J Malaysia, 2001 Dec;56(4):463-70.
    PMID: 12014767
    The results of a prospective study of 94 patients with history of ear, nose or aerodigestive tract foreign bodies were analysed. Sixty six to 94% of patients presented within 24 hours to a primary care doctor, 80 to 94% was referred to the ENT Department within 24 hours and 89 to 93% of patients had their foreign bodies removed within 24 hours. Overall, 58% of aural foreign bodies, 67% nasal foreign bodies and 94% of aerodigestive tract foreign bodies were removed within 48 hours of insertion. As a result of the prompt removal of foreign bodies in the majority of patients, no significant complications occurred. Foreign bodies in the aerodigestive tract tend to present earlier and more promptly removed compared with ear and nose foreign bodies. There was a significantly higher proportion of foreign body in the right ear and nostril compared to the left.

    Study site: ENT Department, Hospital Kuala Lumpur
    Matched MeSH terms: Foreign Bodies/epidemiology*; Foreign Bodies/therapy*
  20. Beshay N, Keay L, Dunn H, Kamalden TA, Hoskin AK, Watson SL
    Injury, 2017 Jul;48(7):1348-1354.
    PMID: 28438416 DOI: 10.1016/j.injury.2017.04.035
    BACKGROUND: Open globe injuries (OGIs) account for 44% of the cost of ocular trauma within Australia. It is estimated that 90% of ocular trauma is preventable. However, there have been few epidemiological studies within Australia that have identified groups at risk of OGIs specifically. The aim of our study was to review the epidemiology of OGIs presenting to a tertiary referral eye hospital in Australia.

    METHODS: The Birmingham Eye Trauma Terminology (BETT) system was used to classify injuries as globe ruptures, penetrating eye injuries (PEIs), intraocular foreign bodies (IOFBs) or perforating injuries. Demographic data, past ocular history, mechanism of trauma, ocular injuries, and best-corrected visual acuity (BCVA) before and after treatment were recorded.

    RESULTS: The 205 OGIs included 80 globe ruptures, 71 PEIs, 48 IOFBs and six perforating injuries. Falls predominated in older age groups compared to the other mechanisms of injury (p<0.0001). A fall was responsible for 33 globe ruptures and 82% of these had a history of previous intraocular surgery. Globe rupture and perforating injuries had poorer visual outcomes (p<0.05), consistent with previous studies. Alcohol was implicated in 20 cases of OGI, with 11 of these due to assault. PEIs and IOFBs commonly occurred while working with metal. BCVA was significantly worse following removal of an intraocular foreign body. We found presenting BCVA to be a good predictor of BCVA at the time of discharge.

    CONCLUSIONS: The causes of OGI varied in association with age, with older people mostly incurring their OGI through falls and younger adults through assault and working with metal. Globe ruptures occurring after a fall often had a history of intraocular surgery. The initial BCVA is useful for non-ophthalmologists who are unfamiliar with the ocular trauma score to help predict the BCVA following treatment.

    Matched MeSH terms: Eye Foreign Bodies/epidemiology*; Eye Foreign Bodies/physiopathology
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links