Displaying publications 41 - 60 of 173 in total

Abstract:
Sort:
  1. Srivastava G, Padhiary SK, Mohanty N, Patil PG, Panda S, Cobo-Vazquez C, et al.
    Acta Odontol Scand, 2024 Jun 19;83:392-403.
    PMID: 38895776 DOI: 10.2340/aos.v83.40870
    OBJECTIVES: To evaluate the current evidence of digital workflow feasibility based on the data acquisition methods and the software tools used to fabricate intraoral prostheses for patients with partial or total maxillary and mandibular defects.

    MATERIALS AND METHODS: An electronic search was performed in PubMed, SCOPUS, and Web of Science using a combination of relevant keywords: digital workflow, digital designing, computer-assisted design-computer aided manufacturing, 3D printing, maxillectomy, and mandibulectomy. The Joanna Briggs Institute Critical Appraisal Tool was used to assess the quality of evidence in the studies reviewed.

    RESULTS: From a total of 542 references, 33 articles were selected, including 25 on maxillary prostheses and 8 on mandibular prostheses. The use of digital workflows was limited to one or two steps of the fabrication of the prostheses, and only four studies described a complete digital workflow. The most preferred method for data acquisition was intraoral scanning with or without a cone beam computed tomography combination.

    CONCLUSION: Currently, the fabrication process of maxillofacial prostheses requires combining digital and conventional methods. Simplifying the data acquisition methods and providing user-friendly and affordable software may encourage clinicians to use the digital workflow more frequently for patients requiring maxillofacial prostheses.

    Matched MeSH terms: Prosthesis Design
  2. Keun Seon J, Anwar Ayob K, Giun Noh M, Yeol Yang H
    Acta Orthop Traumatol Turc, 2024 Jan;58(1):68-72.
    PMID: 38525513 DOI: 10.5152/j.aott.2024.23115
    Oxidized zirconium (OxiniumTM) prostheses, made up of a metallic alloy of zirconium with a ceramic surface formed by oxidizing the outer layer, were developed as an alternative bearing surface to reduce polyethylene wear and decrease failure of total knee arthroplasty (TKA). We report a unique catastrophic failure of an Oxinium TKA with consequent accelerated wear and severe metallosis. Intraoperatively, we observed extensive wear grooving of the femoral component with exposure of the underlying silver layers and the complete wear of polyethylene on the medial side. Metallic debris had a peculiar arthrogram appearance, noted within the cut surface of the femur and tibia, indicative of the osteolysis that occurred, leading up to the failure of the implants. The histopathologic examination revealed a collection of macrophages with foreign-body reactions and black-pigmented metal-induced wear particles. Oxinium has clear benefits regarding superior wear properties; however, surgeons need to be aware that there is a risk of exposure to the underlying layers that may precede accelerated wear, deformation, and metallosis. Uncovering the deeper layers could result in the appearance of an arthrogram on plain radiographs. Early identification of polyethylene wear and prompt revision is crucial to avoid the rapid progression of subsequent metallosis and catastrophic implant failure, specifically when using oxidized zirconium components for TKA. To the best of our knowledge, this is the first report presenting a detailed histologic analysis to provide insight into the mechanisms of the failed Oxinium components.
    Matched MeSH terms: Prosthesis Design
  3. Khamis T, Khamis AA, Al Kouzbary M, Al Kouzbary H, Mokayed H, AbdRazak NA, et al.
    Artif Intell Med, 2024 Oct;156:102966.
    PMID: 39197376 DOI: 10.1016/j.artmed.2024.102966
    This comprehensive systematic review critically analyzes the current progress and challenges in automating transtibial prosthesis alignment. The manual identification of alignment changes in prostheses has been found to lack reliability, necessitating the development of automated processes. Through a rigorous systematic search across major electronic databases, this review includes the highly relevant studies out of an initial pool of 2111 records. The findings highlight the urgent need for automated alignment systems in individuals with transtibial amputation. The selected studies represent cutting-edge research, employing diverse approaches such as advanced machine learning algorithms and innovative alignment tools, to automate the detection and adjustment of prosthesis alignment. Collectively, this review emphasizes the immense potential of automated transtibial prosthesis alignment systems to enhance alignment accuracy and significantly reduce human error. Furthermore, it identifies important limitations in the reviewed studies, serving as a catalyst for future research to address these gaps and explore alternative machine learning algorithms. The insights derived from this systematic review provide valuable guidance for researchers, clinicians, and developers aiming to propel the field of automated transtibial prosthesis alignment forward.
    Matched MeSH terms: Prosthesis Design
  4. Ali S, Osman NA, Razak A, Hussain S, Wan Abas WA
    Eur J Phys Rehabil Med, 2015 Feb;51(1):31-7.
    PMID: 24963603
    Lower limb amputee's are greatly affected in dealing with the environmental barriers such as ramps and stairs and reported high interface pressure between the residual limb and socket/liner. Interface pressure between the residual limb and socket/liner can affect the satisfaction and use of the prosthesis. Until now, little attention has been paid to interface pressure between socket and stump during ramp negotiation and its effect on amputee's satisfaction.
    Matched MeSH terms: Prosthesis Design*
  5. Buzayan MM
    Prosthet Orthot Int, 2014 Feb;38(1):62-7.
    PMID: 23625838 DOI: 10.1177/0309364613484052
    Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication.
    Matched MeSH terms: Prosthesis Design*
  6. Tarib NA, Seong TW, Chuen KM, Kun MS, Ahmad M, Kamarudin KH
    Eur J Prosthodont Restor Dent, 2012 Mar;20(1):35-9.
    PMID: 22474935
    This paper aims to evaluate the effect of splinting during implant impression. A master model with two fixtures at the sites of 45 and 47 was used. 20 impressions were made for all four techniques: (A) indirect; (B) direct, unsplinted; (C) direct, splinted; and (D) direct, splinted, sectioned, and re-splinted. Splinting was undertaken with autopolymerizing acrylic resin (AAR). Horizontal distance between fixtures was compared using a digital caliper. The difference in distance were analysed with one-way ANOVA. Group A showed a significantly lowest accuracy among all techniques (p < or = 0.05). There was no significant difference of accuracy among the groups using direct techniques (p > or = 0.05). Group D was more accurate compared to group B and C. We conclude that splinting of impression copings would be beneficial to obtain an accurate impression.
    Matched MeSH terms: Dental Prosthesis Design*
  7. Abd Razak NA, Abu Osman NA, Wan Abas WA
    Disabil Rehabil Assist Technol, 2013 May;8(3):255-60.
    PMID: 22830946 DOI: 10.3109/17483107.2012.704654
    This study examined the kinematic differences between a body-powered prosthesis and a biomechatronics prosthesis as a transradial amputee performed activities that involve flexion/extension and supination/pronation of the wrist.
    Matched MeSH terms: Prosthesis Design*
  8. Sockalingam S
    J Indian Soc Pedod Prev Dent, 2011 Jan-Mar;29(1):53-6.
    PMID: 21521920 DOI: 10.4103/0970-4388.79938
    Amelogenesis imperfecta represents a group of dental developmental conditions that are genomic in origin. Hypoplastic AI, hypomineralised AI or both in combination were the most common types seen clinically. This paper describes oral rehabilitation of a 9-year-old Malay girl with inherited hypoplastic AI using transparent thermoforming templates. The defective surface areas were reconstructed to their original dimensions on stone cast models of the upper and lower arches using composite, and transparent thermoform templates were fabricated on the models. The templates were used as crown formers to reconstruct the defective teeth clinically using esthetically matching composite. The usage of the templates allowed direct light curing of the composite, accurate reproducibility of the anatomic contours of the defective teeth, reduced chair-side time and easy contouring and placement of homogenous thickness of composite in otherwise inaccessible sites of the affected teeth.
    Matched MeSH terms: Dental Prosthesis Design*
  9. Baig MR, Tan KB, Nicholls JI
    J Prosthet Dent, 2010 Oct;104(4):216-27.
    PMID: 20875526 DOI: 10.1016/S0022-3913(10)60128-X
    The marginal fit of crowns is a concern for clinicians, and there is no conclusive evidence of any one margin configuration yielding better results than others in terms of marginal fit.
    Matched MeSH terms: Dental Prosthesis Design*
  10. Eshraghi A, Abu Osman NA, Karimi MT, Gholizadeh H, Ali S, Wan Abas WA
    Am J Phys Med Rehabil, 2012 Dec;91(12):1028-38.
    PMID: 23168378 DOI: 10.1097/PHM.0b013e318269d82a
    The objectives of this study were to compare the effects of a newly designed magnetic suspension system with that of two existing suspension methods on pistoning inside the prosthetic socket and to compare satisfaction and perceived problems among transtibial amputees.
    Matched MeSH terms: Prosthesis Design*
  11. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Sævarsson SK, Wan Abas WA, et al.
    J Rehabil Res Dev, 2012;49(9):1321-30.
    PMID: 23408214
    Poor suspension increases slippage of the residual limb inside the socket during ambulation. The main purpose of this article is to evaluate the pistoning at the prosthetic liner-socket interface during gait and assess patients' satisfaction with two different liners. Two prostheses with seal-in and locking liners were fabricated for each of the 10 subjects with transtibial amputation. The Vicon motion system was used to measure the pistoning during gait. The subjects were also asked to complete a Prosthesis Evaluation Questionnaire. The results revealed higher pistoning inside the socket during gait with the locking liner than with the seal-in liner (p < 0.05). The overall satisfaction with the locking liner was higher (p < 0.05) because of the relative ease with which the patients could don and doff the device. As such, pistoning may not be the main factor that determines patients' overall satisfaction with the prosthesis and other factors may also contribute to comfort and satisfaction with prostheses. The article also verifies the feasibility of the Vicon motion system for measuring pistoning during gait.
    Matched MeSH terms: Prosthesis Design*
  12. Shankargouda SB, Sidhu P, Kardalkar S, Desai PM
    J Prosthodont, 2017 Feb;26(2):168-171.
    PMID: 26479878 DOI: 10.1111/jopr.12385
    Residual ridge resorption is a rapid, progressive, irreversible, and inevitable process of bone resorption. Long-standing teeth and implants have been shown to have maintained the bone around them without resorption. Thus, overdenture therapy has been proven to be beneficial in situations where few remaining teeth are present. In addition to the various advantages seen with tooth-supported telescopic overdentures, a few shortcomings can also be expected, including unseating of the overdenture, increased bulk of the prosthesis, secondary caries, etc. The precise transfer of the secondary telescopic copings to maintain the spatial relationship, without any micromovement, remains the most critical step in ensuring the success of the tooth-supported telescopic prosthesis. Thus, a simple and innovative technique of splinting the secondary copings was devised to prevent distortion and micromovement and maintain its spatial relationship.
    Matched MeSH terms: Dental Prosthesis Design*
  13. Wahab AH, Kadir MR, Harun MN, Kamarul T, Syahrom A
    Med Biol Eng Comput, 2017 Mar;55(3):439-447.
    PMID: 27255451 DOI: 10.1007/s11517-016-1525-6
    The present study was conducted to compare the stability of four commercially available implants by investigating the focal stress distributions and relative micromotion using finite element analysis. Variations in the numbers of pegs between the implant designs were tested. A load of 750 N was applied at three different glenoid positions (SA: superior-anterior; SP: superior-posterior; C: central) to mimic off-center and central loadings during activities of daily living. Focal stress distributions and relative micromotion were measured using Marc Mentat software. The results demonstrated that by increasing the number of pegs from two to five, the total focal stress volumes exceeding 5 MPa, reflecting the stress critical volume (SCV) as the threshold for occurrence of cement microfractures, decreased from 8.41 to 5.21 % in the SA position and from 9.59 to 6.69 % in the SP position. However, in the C position, this change in peg number increased the SCV from 1.37 to 5.86 %. Meanwhile, micromotion appeared to remain within 19-25 µm irrespective of the number of pegs used. In conclusion, four-peg glenoid implants provide the best configuration because they had lower SCV values compared with lesser-peg implants, preserved more bone stock, and reduced PMMA cement usage compared with five-peg implants.
    Matched MeSH terms: Prosthesis Design*
  14. Noroozi S, Ong ZC, Khoo SY, Aslani N, Sewell P
    Prosthet Orthot Int, 2019 Feb;43(1):62-70.
    PMID: 30051756 DOI: 10.1177/0309364618789449
    BACKGROUND:: The current method of prescribing composite running-specific energy-storing-and-returning feet is subjective and is based only on the amputee's static body weight/mass.

    OBJECTIVES:: The aim was to investigate their dynamic characteristics and create a relationship between these dynamic data and the prescription of foot.

    STUDY DESIGN:: Experimental Assessment.

    METHODS:: This article presents the modal analysis results of the full range of Össur Flex-Run™ running feet that are commercially available (1LO-9LO) using experimental modal analysis technique under a constant mass at 53 kg and boundary condition.

    RESULTS:: It was shown that both the undamped natural frequency and stiffness increase linearly from the lowest to the highest stiffness category of foot which allows for a more informed prescription of foot when tuning to a matched natural frequency. The low damping characteristics determined experimentally that ranged between 1.5% and 2.0% indicates that the feet require less input energy to maintain the steady-state cyclic motion before take-off from the ground. An analysis of the mode shapes also showed a unique design feature of these feet that is hypothesised to enhance their performance.

    CONCLUSION:: A better understanding of dynamic characteristics of the feet can help tune the feet to the user's requirements in promoting a better gait performance.

    CLINICAL RELEVANCE: The dynamic data determined from this study are needed to better inform the amputees in predicting the natural frequency of the foot prescribed. The amputees can intuitively tune the cyclic body rhythm during walking or running to match with the natural frequency. This could eventually promote a better gait performance.

    Matched MeSH terms: Prosthesis Design/methods*
  15. Gholizadeh H, Lemaire ED, Eshraghi A
    Clin Biomech (Bristol, Avon), 2016 08;37:108-116.
    PMID: 27423025 DOI: 10.1016/j.clinbiomech.2016.06.005
    BACKGROUND: An optimal suspension system can improve comfort and quality of life in people with limb loss. To guide practice on prosthetic vacuum suspension systems, assessment of the current evidence and professional opinion are required.

    METHODS: PubMed, Web of Science, and Google Scholar databases were explored to find related articles. Search terms were amputees, artificial limb, prosthetic suspension, prosthetic liner, vacuum, and prosthesis. The results were refined by vacuum socket or vacuum assisted suspension or sub-atmospheric suspension. Study design, research instrument, sample size, and outcome measures were reviewed. An online questionnaire was also designed and distributed worldwide among professionals and prosthetists (www.ispoint.org, OANDP-L, LinkedIn, personal email).

    FINDINGS: 26 articles were published from 2001 to March 2016. The number of participants averaged 7 (SD=4) for transtibial and 6 (SD=6) for transfemoral amputees. Most studies evaluated the short-term effects of vacuum systems by measuring stump volume changes, gait parameters, pistoning, interface pressures, satisfaction, balance, and wound healing. 155 professionals replied to the questionnaire and supported results from the literature. Elevated vacuum systems may have some advantages over the other suspension systems, but may not be appropriate for all people with limb loss.

    INTERPRETATION: Elevated vacuum suspension could improve comfort and quality of life for people with limb loss. However, future investigations with larger sample sizes are needed to provide strong statistical conclusions and to evaluate long-term effects of these systems.

    Matched MeSH terms: Prosthesis Design*
  16. Abu Osman NA, Gholizadeh H, Eshraghi A, Wan Abas WAB
    Prosthet Orthot Int, 2017 Oct;41(5):476-483.
    PMID: 28946824 DOI: 10.1177/0309364616670396
    OBJECTIVES: This study aimed to evaluate and compare a newly designed suspension system with a common suspension in the market.

    STUDY DESIGN: Prospective study.

    METHODS: Looped liners with hook fastener and Iceross Dermo Liner with pin/lock system were mechanically tested using a tensile testing machine in terms of system safety. A total of 10 transtibial amputees participated in this study and were asked to use these two different suspension systems. The pistoning was measured between the liner and socket through a photographic method. Three static axial loading conditions were implemented, namely, 30, 60, and 90 N. Furthermore, subjective feedback was obtained.

    RESULTS: Tensile test results showed that both systems could safely tolerate the load applied to the prosthesis during ambulation. Clinical evaluation confirmed extremely low pistoning in both systems (i.e. less than 0.4 cm after adding 90 N traction load to the prosthesis). Subjective feedback also showed satisfaction with both systems. However, less traction at the end of the residual limb was reported while looped liner was used.

    CONCLUSION: The looped liner with hook fastener is safe and a good alternative for individuals with transtibial amputation as this system could solve some problems with the current systems. Clinical relevance The looped liner and hook fastener were shown to be good alternative suspension for people with lower limb amputation especially those who have difficulty to use and align the pin/lock systems. This system could safely tolerate centrifugal forces applied to the prosthesis during normal and fast walking.

    Matched MeSH terms: Prosthesis Design/methods*
  17. Baig MR, Buzayan MM, Yunus N
    J Investig Clin Dent, 2018 May;9(2):e12320.
    PMID: 29349910 DOI: 10.1111/jicd.12320
    AIM: The aim of the present study was to assess the accuracy of multi-unit dental implant casts obtained from two elastomeric impression materials, vinyl polyether silicone (VPES) and polyether (PE), and to test the effect of splinting of impression copings on the accuracy of implant casts.

    METHODS: Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05.

    RESULTS: The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05).

    CONCLUSIONS: The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions.

    Matched MeSH terms: Dental Prosthesis Design*
  18. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    PLoS One, 2014;9(5):e94520.
    PMID: 24827560 DOI: 10.1371/journal.pone.0094520
    The suction sockets that are commonly prescribed for transtibial amputees are believed to provide a better suspension than the pin/lock systems. Nevertheless, their effect on amputees' gait performance has not yet been fully investigated. The main intention of this study was to understand the potential effects of the Seal-in (suction) and the Dermo (pin/lock) suspension systems on amputees' gait performance.
    Matched MeSH terms: Prosthesis Design/instrumentation; Prosthesis Design/psychology*
  19. Gholizadeh H, Abu Osman NA, Kamyab M, Eshraghi A, Lúvíksdóttir AG, Wan Abas WA
    Am J Phys Med Rehabil, 2012 Oct;91(10):894-8.
    PMID: 22173083
    The effects of Seal-In X5 and Dermo liner (Össur) on suspension and patient's comfort in lower limb amputees are unclear. In this report, we consider the case of a 51-yr-old woman with bilateral transtibial amputation whose lower limbs were amputated because of peripheral vascular disease. The subject had bony and painful residual limbs, especially at the distal ends. Two prostheses that used Seal-In X5 liners and a pair of prostheses with Dermo liners were fabricated, and the subject wore each for a period of 2 wks. Once the 2 wks had passed, the pistoning within the socket was assessed and the patient was questioned as to her satisfaction with both liners. This study revealed that Seal-In X5 liner decreased the residual limb pain experienced by the patient and that 1-2 mm less pistoning occurred within the socket compared with the Dermo liner. However, the patient needed to put in extra effort for donning and doffing the prosthesis. Despite this, it is clear that the Seal-In X5 liner offers a viable alternative for individuals with transtibial amputations who do not have enough soft tissue around the bone, especially at the end of the residual limb.
    Matched MeSH terms: Prosthesis Design/instrumentation*; Prosthesis Design/methods
  20. Pirouzi G, Abu Osman NA, Oshkour AA, Ali S, Gholizadeh H, Abas WA
    Sensors (Basel), 2014;14(9):16754-65.
    PMID: 25207872 DOI: 10.3390/s140916754
    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded.
    Matched MeSH terms: Prosthesis Design