Displaying publications 41 - 60 of 1883 in total

Abstract:
Sort:
  1. Delilkan AE, Sannasi RV
    Singapore Med J, 1983 Feb;24(1):23-6.
    PMID: 6346504
    The practice of continuing ventilation into the post·operatlve period in certain poor risk patients resulted in a reduction in morbidity and mortality. So much more surgery can be performed on many patients which otherwise would not be justified without this back·up services provided by the intensive therapy unit. From 1970 - 80, 763 patients were electively ventilated following surgery (both elective and emergency) of which 115 died, giving a mortality incidence of 15.01%
    Matched MeSH terms: Intermittent Positive-Pressure Ventilation*
  2. Park S, Buranakitjaroen P, Chen CH, Chia YC, Divinagracia R, Hoshide S, et al.
    J Hum Hypertens, 2018 Apr;32(4):249-258.
    PMID: 29386668 DOI: 10.1038/s41371-017-0025-y
    Hypertension is the leading cause of mortality throughout Asia. Home blood pressure monitoring has the potential to improve hypertension control and is a useful adjunct to conventional office blood pressure measurements due to its diagnostic accuracy and prognostic value in predicting cardiovascular outcomes. At present, there are no region-specific guidelines addressing the use of home blood pressure monitoring in Asia. Therefore, an expert panel was convened to address the use of home blood pressure monitoring and develop key recommendations to help guide clinical practice throughout the Asia region. The resulting recommendations support the use of home blood pressure monitoring with a validated device as an accurate adjunct for diagnosing hypertension and predicting cardiovascular outcome. Diagnosis and treatment of hypertension should still be guided by conventional office/clinic blood pressure measurements. The expert panel encourages the incorporation of home blood pressure monitoring into local clinical guidelines and offers practical recommendations to ensure continuity of care where a validated home blood pressure device is not available.
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory*
  3. Najmul Hejaz Azmi S, Aqib Nasir Al Rawahi W, Ibrahim Al Yahyai A, Ali Al Qasimi A, Saif Al Fuliti K, Said Al Qalhati O, et al.
    PMID: 38309045 DOI: 10.1016/j.jchromb.2024.124035
    A UV-HPLC method optimized by Box-Behnken design model was developed to determine caffeine in pharmaceutical preparations and urine samples. The chromatographic conditions followed were mobile phase: methanol/water/ citrate buffer (pH 4.6) (40:25:35, v/v/v),AcclaimTMDionex C18 column (ODS 100A˚, 5 µm; 4.6 × 250 mm),flow rate (0.9 mL min-1), column temperature (30 °C) and UV-detection wavelength (204 nm). The chromatographic variables: pH (A), % methanol fraction (B), flow rate(C) and column temperature (D) were optimized at 50 μg mL-1caffeine using BBD model. The chromatogram resulted in the asymmetry factor (1.23), theoretical plate 13,786 and retention time (5.79 min). The proposed HPLC method's greenness point was assessed byAnalytical Eco-scale and found to be 78 (as per guidelines, ranked as excellent). The linearity was ranged from2.0 to 70 µg mL-1 with coefficient of correlation (r = 0.999) and detection limit of 0.19 µg mL-1. The proposedmethod was developed successfully and applied for the assay of active caffeine in pharmaceutical preparations and urine samples. The % recovery obtained by both (proposed and reference) methods ranged from 99.98 to 100.05 % followed the compliance (100 ± 2 %) with Canadian Health Protection regulatory guidelines. The performance of the proposed method was compared with published papers and found to be acceptable and superior. The proposed method was quite effective as the reference method, and hence can be used as an alternative method for the assay of active caffeine in pharmaceutical preparations and urine samples.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  4. Tomitani N, Hoshide S, Buranakitjaroen P, Chia YC, Park S, Chen CH, et al.
    J Clin Hypertens (Greenwich), 2021 03;23(3):606-613.
    PMID: 33694262 DOI: 10.1111/jch.14239
    Increased heart rate is a predictor of cardiovascular disease, heart failure, and all-cause mortality. In those with high heart rates, interventions for heart rate reduction have been associated with reductions in coronary events. Asia is a diverse continent, and the prevalences of hypertension and cardiovascular disease differ among its countries. The present analysis of AsiaBP@Home study data investigated differences among resting heart rates (RHRs) in 1443 hypertensive patients from three Asian regions: East Asia (N = 595), Southeast Asia (N = 680), and South Asia (N = 168). This is the first study to investigate self-measured RHR values in different Asian countries/regions using the same validated home BP monitoring device (Omron HEM-7130-AP/HEM-7131-E). Subjects in South Asia had higher RHR values compared with the other two regions, and the regional tendency found in RHR values was different from that found in BP values. Even after adjusting for age, sex, BMI, habitual alcohol consumption, current smoking habit, shift worker, hyperlipidemia, diabetes, chronic kidney disease, history of heart failure, and beta-blocker use, both office and home RHR values in South Asia were the highest among Asia (mean values ± SE of office: East Asia [E] 75.2 ± 1.5 bpm, Southeast Asia [Se] 76.7 ± 1.5 bpm, South Asia [S] 81.9 ± 1.4 bpm; home morning: [E] 69.0 ± 1.2 bpm, [Se] 72.9 ± 1.2 bpm, [S] 74.9 ± 1.1 bpm; home evening: [E] 74.6 ± 1.2 bpm, [Se] 78.3 ± 1.2 bpm, [S] 83.8 ± 1.1 bpm). Given what is known about the impact of RHR on heart disease, our findings suggest the possible benefit of regionally tailored clinical strategies for cardiovascular disease prevention.
    Matched MeSH terms: Blood Pressure Determination; Blood Pressure Monitoring, Ambulatory
  5. Chia YC, Kario K, Tomitani N, Park S, Shin J, Turana Y, et al.
    J Clin Hypertens (Greenwich), 2020 03;22(3):407-414.
    PMID: 31891447 DOI: 10.1111/jch.13731
    Blood pressure variability (BPV) has been shown to be independently associated with cardiovascular (CV) mortality and morbidity. Patients with type 2 diabetes mellitus (T2DM) have also been shown to have increased BPV. We aimed to compare BPV in hypertensive patients with diabetes with those without diabetes. A total of 1443 hypertensive patients measured their blood pressure (BP) twice in the morning and twice before bed at home for a week. Demographic data, history of T2DM, and anti-hypertensive use were captured. Clinic BP was measured twice in the clinic. Control of BP was defined as clinic systolic BP (SBP) <140 mm Hg and home SBP 
    Matched MeSH terms: Blood Pressure; Blood Pressure Monitoring, Ambulatory
  6. Xi B, Zong X, Kelishadi R, Hong YM, Khadilkar A, Steffen LM, et al.
    Circulation, 2016 Jan 26;133(4):398-408.
    PMID: 26671979 DOI: 10.1161/CIRCULATIONAHA.115.017936
    Several distributions of country-specific blood pressure (BP) percentiles by sex, age, and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limits international comparisons of the prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents by using 7 nationally representative data sets (China, India, Iran, Korea, Poland, Tunisia, and the United States).
    Matched MeSH terms: Blood Pressure/physiology*; Blood Pressure Determination/methods; Blood Pressure Determination/standards*
  7. Saaid M, Saad B, Ali AS, Saleh MI, Basheer C, Lee HK
    J Chromatogr A, 2009 Jul 3;1216(27):5165-70.
    PMID: 19481215 DOI: 10.1016/j.chroma.2009.04.091
    Hollow fibre liquid-phase microextraction with in situ derivatization using dansyl chloride has been successfully developed for the high-performance liquid chromatography-ultraviolet (HPLC-UV) determination of the biogenic amines (tryptamine, putrescine, cadaverine, histamine, tyramine, spermidine) in food samples. Parameters affecting the performance of the in situ derivatization process such as type of extraction solvent, temperature, extraction time, stirring speed and salt addition were studied and optimized. Under the optimized conditions (extraction solvent, dihexyl ether; acceptor phase, 0.1M HCl; extraction time, 30 min; extraction temperature, 26 degrees C; without addition of salt), enrichment factors varying from 47 to 456 were achieved. Good linearity of the analytes was obtained over a concentration range of 0.1-5 microg mL(-1) (with correlation coefficients of 0.9901-0.9974). The limits of detection and quantification based on a signal-to-noise ratio of 3-10, ranged from 0.0075 to 0.030 microg mL(-1) and 0.03 to 0.10 microg mL(-1), respectively. The relative standard deviations based on the peak areas for six replicate analysis of water spiked with 0.5 microg mL(-1) of each biogenic amine were lower than 7.5%. The method was successfully applied to shrimp sauce and tomato ketchup samples, offering an interesting alternative to liquid-liquid extraction and solid phase extraction for the analysis of biogenic amines in food samples.
    Matched MeSH terms: Chromatography, High Pressure Liquid/instrumentation; Chromatography, High Pressure Liquid/methods*
  8. Abdullah A, Liew SM, Hanafi NS, Ng CJ, Lai PS, Chia YC, et al.
    Patient Prefer Adherence, 2016;10:99-106.
    PMID: 26869773 DOI: 10.2147/PPA.S94687
    BACKGROUND: Telemonitoring of home blood pressure (BP) is found to have a positive effect on BP control. Delivering a BP telemonitoring service in primary care offers primary care physicians an innovative approach toward management of their patients with hypertension. However, little is known about patients' acceptance of such service in routine clinical care.
    OBJECTIVE: This study aimed to explore patients' acceptance of a BP telemonitoring service delivered in primary care based on the technology acceptance model (TAM).
    METHODS: A qualitative study design was used. Primary care patients with uncontrolled office BP who fulfilled the inclusion criteria were enrolled into a BP telemonitoring service offered between the period August 2012 and September 2012. This service was delivered at an urban primary care clinic in Kuala Lumpur, Malaysia. Twenty patients used the BP telemonitoring service. Of these, 17 patients consented to share their views and experiences through five in-depth interviews and two focus group discussions. An interview guide was developed based on the TAM. The interviews were audio-recorded and transcribed verbatim. Thematic analysis was used for analysis.
    RESULTS: Patients found the BP telemonitoring service easy to use but struggled with the perceived usefulness of doing so. They expressed confusion in making sense of the monitored home BP readings. They often thought about the implications of these readings to their hypertension management and overall health. Patients wanted more feedback from their doctors and suggested improvement to the BP telemonitoring functionalities to improve interactions. Patients cited being involved in research as the main reason for their intention to use the service. They felt that patients with limited experience with the internet and information technology, who worked out of town, or who had an outdoor hobby would not be able to benefit from such a service.
    CONCLUSION: Patients found BP telemonitoring service in primary care easy to use but needed help to interpret the meanings of monitored BP readings. Implementations of BP telemonitoring service must tackle these issues to maximize the patients' acceptance of a BP telemonitoring service.
    Matched MeSH terms: Blood Pressure; Blood Pressure Determination*
  9. Muhammad J, Jamial MM, Ishak A
    Korean J Fam Med, 2019 Sep;40(5):335-343.
    PMID: 30636386 DOI: 10.4082/kjfm.18.0026
    BACKGROUND: Home blood pressure monitoring is recommended to achieve controlled blood pressure. This study evaluated home blood pressure monitoring-improvement of office blood pressure control and treatment compliance among hypertensive patients.

    METHODS: A randomized controlled trial was conducted from December 2014 to April 2015. The home blood pressure monitoring group used an automatic blood pressure device along with standard hypertension outpatient care. Patients were seen at baseline and after 2 months. Medication adherence was measured using a novel validated Medication Adherence Scale (MAS) questionnaire. Office blood pressure and MAS were recorded at both visits. The primary outcomes included evaluation of mean office blood pressure and MAS within groups and between groups at baseline and after 2 months.

    RESULTS: Mean changes in systolic blood pressure (SBP) and diastolic blood pressure (DBP) and MAS differed significantly within groups. The home blood pressure monitoring group showed greater mean changes (SBP 17.6 mm Hg, DBP 9.5 mm Hg, MAS 1.5 vs. SBP 14.3 mm Hg, DBP 6.4 mm Hg, MAS 1.3), while between group comparisons showed no significant differences across all variables. The adjusted mean difference for mean SBP was 4.74 (95% confidence interval [CI], -0.65 to 10.13 mm Hg; P=0.084), mean DBP was 1.41 (95% CI, -2.01 to 4.82 mm Hg; P=0.415), and mean MAS was 0.05 (95% CI, -0.29 to 0.40 mm Hg; P=0.768).

    CONCLUSION: Short-term home blood pressure monitoring significantly reduced office blood pressure and improved medication adherence, albeit similarly to standard care.

    Matched MeSH terms: Blood Pressure; Blood Pressure Determination; Blood Pressure Monitoring, Ambulatory
  10. Beth, Mini Rani Mary, Shin, Yan Low, Poh, Yoke Chung
    MyJurnal
    Self-blood pressure monitoring (SBPM) at home creates greater awareness and patient participation in their treatment prevents hypertensive complications and helps facilitate doctors to make decisions on treatment. A study was conducted to assess the knowledge on self-blood pressure monitoring (SBPM) among hypertensive patients in selected wards of Hospital Lam Wah Ee, Malaysia. The results showed only 21 (32.3%) respondents monitored their blood pressure and 44 (67.7%) did not monitor their blood pressure at home. A total of 12 (18.4%) respondents reported that they monitored their blood pressure at home because they were aware of complications of hypertension. From those respondents who did not monitor blood pressure at home, only 13 (29.5%) respondents planned to carry out SBPM at home in the future. The overall knowledge score results for self-blood pressure monitoring showed that 6 (9.2%) subjects scored 8 and above, 42 (64.6%) scored 5-7, and 17 (26.1%) scored less than 4. The findings from the study will help the nurses understand the level of knowledge on SBPM among hypertensive patients, and include training and health education during hospitalisation reinforcing the importance and the technique of performing SBPM at home. It also helps to identify patients with poor control of blood pressure so that they can be referred to the physician for further treatment.
    Matched MeSH terms: Blood Pressure; Blood Pressure Determination; Blood Pressure Monitoring, Ambulatory
  11. Lapidaire W, Forkert ND, Williamson W, Huckstep O, Tan CM, Alsharqi M, et al.
    Neuroimage Clin, 2023;37:103337.
    PMID: 36709637 DOI: 10.1016/j.nicl.2023.103337
    IMPORTANCE: Cerebrovascular changes are already evident in young adults with hypertension and exercise is recommended to reduce cardiovascular risk. To what extent exercise benefits the cerebrovasculature at an early stage of the disease remains unclear.

    OBJECTIVE: To investigate whether structured aerobic exercise increases brain vessel lumen diameter or cerebral blood flow (CBF) and whether lumen diameter is associated with CBF.

    DESIGN: Open, parallel, two-arm superiority randomized controlled (1:1) trial in the TEPHRA study on an intention-to-treat basis. The MRI sub-study was an optional part of the protocol. The outcome assessors remained blinded until the data lock.

    SETTING: Single-centre trial in Oxford, UK.

    PARTICIPANTS: Participants were physically inactive (<150 min/week moderate to vigorous physical activity), 18 to 35 years old, 24-hour ambulatory blood pressure 115/75 mmHg-159/99 mmHg, body mass index below 35 kg/m2 and never been on prescribed hypertension medications. Out of 203 randomized participants, 135 participated in the MRI sub-study. Randomisation was stratified for sex, age (<24, 24-29, 30-35 years) and gestational age at birth (<32, 32-37, >37 weeks).

    INTERVENTION: Study participants were randomised to a 16 week aerobic exercise intervention targeting 3×60 min sessions per week at 60 to 80 % peak heart rate.

    MAIN OUTCOMES AND MEASURES: cerebral blood flow (CBF) maps from ASL MRI scans, internal carotid artery (ICA), middle cerebral artery (MCA) M1 and M2 segments, anterior cerebral artery (ACA), basilar artery (BA), and posterior cerebral artery (PCA) diameters extracted from TOF MRI scans.

    RESULTS: Of the 135 randomized participants (median age 28 years, 58 % women) who had high quality baseline MRI data available, 93 participants also had high quality follow-up data available. The exercise group showed an increase in ICA (0.1 cm, 95 % CI 0.01 to 0.18, p =.03) and MCA M1 (0.05 cm, 95 % CI 0.01 to 0.10, p =.03) vessel diameter compared to the control group. Differences in the MCA M2 (0.03 cm, 95 % CI 0.0 to 0.06, p =.08), ACA (0.04 cm, 95 % CI 0.0 to 0.08, p =.06), BA (0.02 cm, 95 % CI -0.04 to 0.09, p =.48), and PCA (0.03 cm, 95 % CI -0.01 to 0.06, p =.17) diameters or CBF were not statistically significant. The increase in ICA vessel diameter in the exercise group was associated with local increases in CBF.

    CONCLUSIONS AND RELEVANCE: Aerobic exercise induces positive cerebrovascular remodelling in young people with early hypertension, independent of blood pressure. The long-term benefit of these changes requires further study.

    TRIAL REGISTRATION: Clinicaltrials.gov NCT02723552, 30 March 2016.

    Matched MeSH terms: Blood Pressure; Blood Pressure Monitoring, Ambulatory*
  12. Subramaniam P, Ho JJ, Davis PG
    Cochrane Database Syst Rev, 2021 Oct 18;10(10):CD001243.
    PMID: 34661278 DOI: 10.1002/14651858.CD001243.pub4
    BACKGROUND: Cohort studies have suggested that nasal continuous positive airway pressure (CPAP) starting in the immediate postnatal period before the onset of respiratory disease (prophylactic CPAP) may be beneficial in reducing the need for intubation and intermittent positive pressure ventilation (IPPV), and in preventing bronchopulmonary dysplasia (BPD), in preterm or low birth weight infants.

    OBJECTIVES: To determine if prophylactic nasal CPAP (started within the first 15 minutes) or very early nasal CPAP regardless of respiratory status (started within the first hour of life), reduces the use of mechanical ventilation and the incidence of bronchopulmonary dysplasia without any adverse effects in preterm infants.

    SEARCH METHODS: A comprehensive search was run on 6 November 2020 in the Cochrane Central Register of Controlled Trials (CENTRAL via CRS Web) and MEDLINE via Ovid. We also searched the reference lists of retrieved studies.

    SELECTION CRITERIA: We included all randomised controlled trials (RCTs) and quasi-RCTs in preterm infants (under 37 weeks of gestation). We included trials if they compared prophylactic nasal CPAP (started within the first 15 minutes) or very early nasal CPAP (started within the first hour of life) in infants with minimal signs of respiratory distress with 'supportive care', such as supplemental oxygen therapy, standard nasal cannula, or mechanical ventilation. We excluded studies where prophylactic CPAP was compared with CPAP along with co-interventions.

    DATA COLLECTION AND ANALYSIS: We used the standard methods of Cochrane Neonatal, including independent study selection, assessment of trial quality, and extraction of data by two review authors.

    MAIN RESULTS: We included eight trials (seven from the previous version of the review and one new study), recruiting 3201 babies, in the meta-analysis. Four trials, involving 765 babies, compared CPAP with supportive care, and three trials (2364 babies) compared CPAP with mechanical ventilation. One trial (72 babies) compared prophylactic CPAP with very early CPAP. Apart from a lack of blinding of the intervention, we judged seven studies to have a low risk of bias. However, one study had a high risk of selection bias. Prophylactic or very early CPAP compared to supportive care There may be a reduction in failed treatment (risk ratio (RR) 0.6, 95% confidence interval (CI) 0.49 to 0.74; risk difference (RD) -0.16, 95% CI -0.34 to 0.02; 4 studies, 765 infants; very low certainty evidence). CPAP possibly reduces BPD at 36 weeks (RR 0.76, 95% CI 0.51 to 1.14; 3 studies, 683 infants, moderate certainty evidence); there may be little or no difference in death (RR 1.04, 95% CI 0.56 to 1.93; 4 studies, 765 infants; moderate certainty evidence). Prophylactic CPAP may reduce the composite outcome of death or BPD (RR 0.69, 95% CI 0.40 to 1.19; 1 study, 256 infants; low certainty evidence). There may be no difference in pulmonary air leak (pneumothorax) (RR 0.75, 95% CI 0.35 to 1.16; 3 studies, 568 infants; low certainty evidence), or intraventricular haemorrhage (IVH) Grade 3 or 4 (RR 0.96, 95% CI 0.39 to 2.37; 2 studies, 486 infants; moderate certainty evidence). Neurodevelopmental impairment was not reported in any of the studies. Prophylactic or very early CPAP compared to mechanical ventilation There was probably a reduction in the incidence of BPD at 36 weeks (RR 0.89, 95% CI 0.8 to 0.99; RD -0.04, 95% CI -0.08 to 0.00; 3 studies, 2150 infants; moderate certainty evidence); and death or BPD (RR 0.89, 95% CI 0.81 to 0.97; RD -0.05, 95% CI -0.09 to 0.01; 3 studies, 2358 infants; moderate certainty evidence). There was also probably a reduction in the need for mechanical ventilation (failed treatment) (RR 0.49, 95% CI 0.45 to 0.54; RD -0.50, 95% CI -0.54 to -0.45; 2 studies, 1042 infants; moderate certainty evidence). There was probably a reduction in the incidence of death (RR 0.82, 95% CI 0.66 to 1.03; 3 studies, 2358 infants; moderate certainty evidence); pulmonary air leak (pneumothorax) (RR 1.24, 95% CI 0.91 to 1.69; 3 studies, 2357 infants; low certainty evidence); and IVH Grade 3 or 4 (RR 1.09, 95% CI 0.86 to 1.39; 3 studies, 2301 infants; moderate certainty evidence). One study in this comparison reported that there was probably little or no difference between the groups in the incidence of neurodevelopmental impairment at 18 to 22 months (RR 0.91, 95% CI 0.62 to 1.32; 976 infants; moderate certainty evidence). Prophylactic CPAP compared with very early CPAP There was one study in this comparison. We are very uncertain whether there is any difference in the incidence of BPD (RR 0.5, 95% CI 0.05 to 5.27; very low certainty evidence). The combined outcome of death and BPD was not reported, and failed treatment was reported but without data. There may have been little to no effect on death (RR 0.75, 95% CI 0.29 to1.94; 1 study, 72 infants; very low certainty evidence). Intraventricular haemorrhage Grade 3 or 4 and neurodevelopmental outcomes were not reported in this study. Pulmonary air leak (pneumothorax) was reported in this study, but there were no events in either group.

    AUTHORS' CONCLUSIONS: For preterm and very preterm infants, there is insufficient evidence to evaluate prophylactic CPAP compared to oxygen therapy and other supportive care. When compared to mechanical ventilation, prophylactic nasal CPAP in very preterm infants reduces the incidence of BPD, the combined outcome of death and BPD, and mechanical ventilation. There is probably no difference in neurodevelopmental impairment at 18 to 22 months of age. When prophylactic CPAP is compared to early CPAP, we are very uncertain about whether there is any difference between prophylactic and very early CPAP. There is no information about the effect of prophylactic or very early CPAP in late preterm infants. There is one study awaiting classification.

    Matched MeSH terms: Intermittent Positive-Pressure Ventilation; Continuous Positive Airway Pressure*
  13. Wang TD, Ohkubo T, Bunyi ML, Chadachan VM, Chia YC, Kario K, et al.
    Hypertens Res, 2023 Jul;46(7):1638-1649.
    PMID: 37041412 DOI: 10.1038/s41440-023-01259-1
    Uncontrolled hypertension is a significant problem in many parts of Asia. Effective management is essential to reduce the burden of hypertension. Home blood pressure monitoring (HBPM) is a promising tool that can aid in the diagnosis and management of hypertension. Experts from 11 countries/regions in Asia conceptualized a large-scale survey to examine the current realities of HBPM. A cross-sectional survey was conducted among health care professionals from China, India, Indonesia, Japan, Malaysia, the Philippines, Singapore, South Korea, Taiwan, Thailand, and Vietnam between November 2019 and June 2021. Physicians' responses were summarized using descriptive statistics. A total of 7945 physicians participated in the survey. Among all respondents, 50.3% and 33.5% viewed HBPM as highly recognized by physicians and patients in their country/region, respectively. Lack of understanding of HBPM and concern with the accuracy and reliability of HBPM devices were identified as key barriers to HBPM recognition. Nearly all physicians (95.9%) reported recommending HBPM to their patients; however, they reported less than 50% of their patients measured home blood pressure (HBP). Among physicians who recommended HBPM, only 22.4% and 54.1% cited HBP diagnostic threshold values and timing of taking antihypertensive drugs that were consistent with available guidelines, respectively. The survey reveals that the recognition of HBPM as a valuable tool to diagnose and manage hypertension is suboptimal in most parts of Asia. Despite high recommendation of HBPM to hypertensive patients by physicians, there are considerable discrepancies between guidelines recommendations and practice realities. The recognition of HBPM as a valuable tool for the diagnosis and management of hypertension is suboptimal among both physicians and patients in Asia. A clear and consistent guidance for proper HBPM practice and use of validated and calibrated HBP monitors are among the top priorities to support the integration of HBPM into daily patient care. HBPM: home blood pressure monitoring, HBP: home blood pressure.
    Matched MeSH terms: Blood Pressure/physiology; Blood Pressure Monitoring, Ambulatory
  14. Atasoy S, Henningsen P, Johar H, Middeke M, Sattel H, Linkohr B, et al.
    J Hypertens, 2024 Mar 01;42(3):521-529.
    PMID: 38088424 DOI: 10.1097/HJH.0000000000003629
    BACKGROUND: The risk of cardiovascular disease (CVD) mortality in individuals with an alerting reaction, assessed by hypertension in the first blood pressure (BP) reading but normal BP in further readings, remains unknown in the general population.

    METHODS AND RESULTS: In a sample of 11 146 adults (51.5% men and 48.5% women) with a mean age of 47.1 years (SD ± 12.3) from a German population-based cohort, we analyzed risk factors and CVD mortality risk associated with an alerting reaction. An alerting reaction was prevalent in 10.2% of the population and associated with sociodemographic, lifestyle, and somatic CVD risk factors. Within a mean follow-up period of 22.7 years (SD ± 7.05 years; max: 32 years; 253 201 person years), 1420 (12.7%) CVD mortality cases were observed. The CVD mortality rate associated with an alerting reaction was significantly higher than in normotension (64 vs. 32 cases/10 000 person-years), but lower than hypertension (118 cases/10 000 person-years). Correspondingly, the alerting reaction was associated with a 23% higher hazard ratio of CVD mortality than normal blood pressure [hazard ratio 1.23 (95% confidence interval 1.02-1.49), P  = 0.04]. However, adjustment for antihypertensive medication use attenuated this association [1.19 (0.99-1.44), P  = 0.06].

    CONCLUSION: The results may warrant monitoring of an alerting reaction as a preventive measure of CVD mortality in untreated individuals with elevated first BP readings, as well as optimized treatment in treated individuals.

    Matched MeSH terms: Blood Pressure/physiology; Blood Pressure Determination
  15. Kario K, Wang JG, Chia YC, Wang TD, Li Y, Siddique S, et al.
    J Clin Hypertens (Greenwich), 2022 Sep;24(9):1112-1120.
    PMID: 36196465 DOI: 10.1111/jch.14555
    Morning hypertension is an important clinical target in the management of hypertension for perfect 24-h blood pressure (BP) control. Morning hypertension is generally categorized into two types: "morning surge" type and "sustained nocturnal and morning hypertension" type. The "morning surge" type is characterized by an exaggerated morning blood pressure surge (MBPS), and the "sustained nocturnal and morning hypertension" type with continuous hypertension from nighttime to morning (non-dipper/riser type). They can be detected by home and ambulatory blood pressure measurements (HBPM and ABPM). These two forms of morning hypertension both increase the risk of cardiovascular and renal diseases, but may occur via different pathogenic mechanisms and are associated with different conditions. Morning hypertension should be treated to achieve a morning BP level of 
    Matched MeSH terms: Blood Pressure/physiology; Blood Pressure Monitoring, Ambulatory
  16. Wang JG, Bunyi ML, Chia YC, Kario K, Ohkubo T, Park S, et al.
    J Clin Hypertens (Greenwich), 2021 Jan;23(1):3-11.
    PMID: 33043574 DOI: 10.1111/jch.14074
    Hypertension is one of the most powerful modifiable risk factors for cardiovascular disease. It is usually asymptomatic and therefore essential to measure blood pressure regularly for the detection of hypertension. Home blood pressure monitoring (HBPM) is recognized as a valuable tool to monitor blood pressure and facilitate effective diagnosis of hypertension. It is useful to identify the masked or white-coat hypertension. There is also increasing evidence that supports the role of HBPM in guiding antihypertensive treatment, and improving treatment compliance and hypertension control. In addition, HBPM has also shown prognostic value in predicting cardiovascular events. Despite these benefits, the use of HBPM in many parts of Asia has been reported to be low. An expert panel comprising 12 leading experts from 10 Asian countries/regions convened to share their perspectives on the realities of HBPM. This article provides an expert summary of the current status of HBPM and the key factors hindering its use. It also describes HBPM-related initiatives in the respective countries/regions and presents strategies that could be implemented to better support the use of HBPM in the management of hypertension.
    Matched MeSH terms: Blood Pressure; Blood Pressure Monitoring, Ambulatory*
  17. Chidambaram R
    J Coll Physicians Surg Pak, 2018 Feb;28(2):169.
    PMID: 29394983 DOI: 10.29271/jcpsp.2018.02.169
    Matched MeSH terms: Blood Pressure/physiology*; Blood Pressure Determination/instrumentation*; Blood Pressure Determination/methods; Blood Pressure Monitors
  18. Razak NA, Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014;13:108.
    PMID: 25085005 DOI: 10.1186/1475-925X-13-108
    The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system.
    Matched MeSH terms: Pressure*
  19. Gholizadeh H, Osman NA, Eshraghi A, Abd Razak NA
    Biomed Eng Online, 2014;13:89.
    PMID: 24981801 DOI: 10.1186/1475-925X-13-89
    Prosthesis suspension systems can alter the distribution of pressure within the prosthetic socket. This study evaluates a new suspension system for lower limb prostheses, and aims to compare the interface pressure and amputees' satisfaction with the new system compared with a common prosthetic suspension system (pin/lock).
    Matched MeSH terms: Pressure*
  20. Al-Faqheri W, Ibrahim F, Thio TH, Moebius J, Joseph K, Arof H, et al.
    PLoS One, 2013;8(3):e58523.
    PMID: 23505528 DOI: 10.1371/journal.pone.0058523
    This paper introduces novel vacuum/compression valves (VCVs) utilizing paraffin wax. A VCV is implemented by sealing the venting channel/hole with wax plugs (for normally-closed valve), or to be sealed by wax (for normally-open valve), and is activated by localized heating on the CD surface. We demonstrate that the VCV provides the advantages of avoiding unnecessary heating of the sample/reagents in the diagnostic process, allowing for vacuum sealing of the CD, and clear separation of the paraffin wax from the sample/reagents in the microfluidic process. As a proof of concept, the microfluidic processes of liquid flow switching and liquid metering is demonstrated with the VCV. Results show that the VCV lowers the required spinning frequency to perform the microfluidic processes with high accuracy and ease of control.
    Matched MeSH terms: Pressure*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links