Displaying publications 41 - 60 of 67 in total

Abstract:
Sort:
  1. Lo TS, Lin YH, Yusoff FM, Chu HC, Hsieh WC, Uy-Patrimonio MC
    Sci Rep, 2016 12 19;6:38960.
    PMID: 27991501 DOI: 10.1038/srep38960
    Our aim is to study the inflammatory response towards the collagen-coated and non-coated polypropylene meshes in rats and the urodynamic investigation post-operatively. Forty-two female Sprague Dawley were divided into 7 groups of 6 rats; Control, Day 7 and 30 for Sham, Avaulta Plus (MPC), Perigee (MP). UDS were taken at days 7 and 30. Mesh with the vagina and bladder wall was removed and sent for immunohistochemical examination. Results showed intense inflammatory reaction on day 7 in the study groups which decreased on day 30. IL-1, TNF-α, MMP-2 and CD31 were observed to decrease from day 7 to day 30. NGF was almost normal on day 30 in all groups. UDS showed no difference in voiding pressure. Both Study and Sham groups had shorter voiding interval (VI) on day 7 but significantly lower in MPC. VI had significantly increased on day 30 in all groups. Voided volume was significantly lower in the mesh groups even when an increase was seen on day 30. In conclusion, the higher levels of IL-1, TNF-α and MMP-2 in collagen-coated polypropylene mesh imply greater inflammation than the non-coated polypropylene mesh. Mesh implantation can lead to shorter voiding interval and smaller bladder capacity.
    Matched MeSH terms: Coated Materials, Biocompatible
  2. Linn YL, Wang JC, Pua U, Yahaya SA, Choke ET, Chong TT, et al.
    Vascular, 2023 Aug;31(4):767-776.
    PMID: 35410542 DOI: 10.1177/17085381221081969
    BACKGROUND: Results from the BIOLUX P-III registry have demonstrated favourable outcomes of Passeo-18 Lux™ (Biotronik®, Buelach, Switzerland) drug-coated balloon in treating obstructive infrainguinal peripheral artery disease, but it has not been established if Asians would benefit to the same extent as non-Asians.

    METHODS: A subgroup analysis was performed on the 24-month data comparing the Asian cohort (AC) to non-Asian cohort (NAC).

    RESULTS: AC included 49 patients with 77 lesions. AC was significantly younger (65.6 vs 70.3 years, p < 0.05), had more diabetes (87.8% vs 45.3%, p < 0.05), and was more likely to present with CLTI (73.5% vs 35.3%, p < 0.001) compared to NAC. They had significantly longer mean target lesions (115 vs 86.9 mm, p = 0.006), and received significantly higher paclitaxel doses (10.7 vs 7.2 mg, p = 0.0005). Device, technical and procedural successes were 125/125(100%), 95/97(97.5%) and 45/49(91.8%), respectively. There was no significant difference in target lesion revascularization rates between groups (10.5% vs 12%, p = 0.91). However, the AC had more major adverse events (30.2% vs 16.1%, p = 0.001), amputations (26.3% vs 6.2%, p < 0.05) and mortality (37.9% vs 10.6%, p < 0.05) at 24 months.

    CONCLUSION: Passeo-18 Lux™ use was efficacious in Asians, but was associated with higher adverse events, amputations and mortality rates, likely attributable to poorer patient comorbidities and more extensive PAD.

    Matched MeSH terms: Coated Materials, Biocompatible
  3. Laricchia A, Bossi I, Latini RA, Lee CY, Pérez IS, Tomai F, et al.
    Rev Esp Cardiol (Engl Ed), 2024 Jul;77(7):527-536.
    PMID: 38056772 DOI: 10.1016/j.rec.2023.11.010
    INTRODUCTION AND OBJECTIVES: The PEACE study (Performance of a sirolimus-eluting balloon strategy in acute and chronic coronary syndromes) investigated for the first time whether a sirolimus-coated balloon (SCB) (Magic Touch, Concept Medical, India) is associated with different outcomes depending on whether it is used in acute coronary syndromes (ACS) or chronic coronary syndromes (CCS).

    METHODS: This was a post-hoc analysis from the all-comers EASTBOURNE Registry (NCT03085823). Out of 2083 patients enrolled, an SCB was used to treat 968 (46.5%) ACS and 1115 (53.5%) CCS patients. The primary endpoint was target lesion revascularization at 12 months, while secondary endpoints were angiographic success and major adverse cardiovascular events.

    RESULTS: Baseline demographics, mean reference vessel diameter and mean lesion length were comparable between ACS and CCS. Predilatation was more commonly performed in ACS (P=.007). SCB was inflated at a standard pressure in both groups with a slight trend toward longer inflation time in ACS. Angiographic success was high in both groups (ACS 97.4% vs CCS 97.7%, P=.820) with limited bailout stenting. Similarly, at 12 months the cumulative incidence of target lesion revascularization (ACS 6.6% vs CCS 5.2%, P=.258) was comparable between ACS and CCS. Conversely, a higher rate of major adverse cardiovascular events in acute presenters was mainly driven by myocardial infarction recurrencies (ACS 10.4% vs CCS 8.3%, P=.009). In-stent restenosis showed a higher proportion of target lesion revascularization and major adverse cardiovascular events than de novo lesions, independently of the type of presentation at the index procedure.

    CONCLUSIONS: This SCB shows good performance in terms of acute and 1-year outcomes independently of the clinical presentation.

    Matched MeSH terms: Coated Materials, Biocompatible
  4. Seiffert J, Hussain F, Wiegman C, Li F, Bey L, Baker W, et al.
    PLoS One, 2015;10(3):e0119726.
    PMID: 25747867 DOI: 10.1371/journal.pone.0119726
    Particle size and surface chemistry are potential determinants of silver nanoparticle (AgNP) respiratory toxicity that may also depend on the lung inflammatory state. We compared the effects of intratracheally-administered AgNPs (20 nm and 110 nm; polyvinylpyrrolidone (PVP) and citrate-capped; 0.1 mg/Kg) in Brown-Norway (BN) and Sprague-Dawley (SD) rats. In BN rats, there was both a neutrophilic and eosinophilic response, while in SD rats, there was a neutrophilic response at day 1, greatest for the 20 nm citrate-capped AgNPs. Eosinophilic cationic protein was increased in bronchoalveolar lavage (BAL) in BN and SD rats on day 1. BAL protein and malondialdehyde levels were increased in BN rats at 1 and 7 days, and BAL KC, CCL11 and IL-13 levels at day 1, with increased expression of CCL11 in lung tissue. Pulmonary resistance increased and compliance decreased at day 1, with persistence at day 7. The 20 nm, but not the 110 nm, AgNPs increased bronchial hyperresponsiveness on day 1, which continued at day 7 for the citrate-capped AgNPs only. The 20 nm versus the 110 nm size were more proinflammatory in terms of neutrophil influx, but there was little difference between the citrate-capped versus the PVP-capped AgNPs. AgNPs can induce pulmonary eosinophilic and neutrophilic inflammation with bronchial hyperresponsiveness, features characteristic of asthma.
    Matched MeSH terms: Coated Materials, Biocompatible/toxicity*
  5. Mustafa A, Lung CY, Mustafa NS, Mustafa BA, Kashmoola MA, Zwahlen RA, et al.
    Clin Oral Implants Res, 2016 Mar;27(3):303-9.
    PMID: 25393376 DOI: 10.1111/clr.12525
    OBJECTIVES: To investigate the effect of eicosapentaenoic acid (EPA)-coated Ti implants on osteoconduction in white New Zealand rabbit mandibles.

    MATERIAL AND METHODS: Sandblasted and cleansed planar titanium specimens with a size of 5 × 5 × 1 mm were coated on one side with 0.25 vol% eicosapentaenoic acid (EPA). The other side of the specimens was kept highly polished (the control side). These specimens were inserted in rabbit mandibles. Twelve rabbits were randomly assigned into three study groups (n = 4). The rabbits were sacrificed at 4, 8, and 12 weeks. The harvested specimens with the implants were assessed for new bone formation on both sides of the implant using CBCT, conventional radiographs, and the biaxial pullout test. The results were statistically analyzed by a nonparametric Kruskal-Wallis test and Friedman's test as multiple comparisons and by Brunner-Langer nonparametric mixed model approach (R Software).

    RESULTS: A significant osteoconductive bone formation was found on the EPA-coated Ti implant surface (P < 0.05) at 8 weeks when compared to the polished surface (control). Biaxial pullout test results showed a significant difference (P < 0.05) after 8 and 12 weeks with a maximum force of 243.8 N, compared to 143.25 N after 4 week.

    CONCLUSION: EPA implant coating promoted osteoconduction on the Ti implant surfaces, enhancing the anchorage of the implant to the surrounding bone in white New Zealand rabbits.

    Matched MeSH terms: Coated Materials, Biocompatible/pharmacology*
  6. Salem SA, Hwei NM, Bin Saim A, Ho CC, Sagap I, Singh R, et al.
    J Biomed Mater Res A, 2013 Aug;101(8):2237-47.
    PMID: 23349110 DOI: 10.1002/jbm.a.34518
    The chief obstacle for reconstructing the bladder is the absence of a biomaterial, either permanent or biodegradable, that will function as a suitable scaffold for the natural process of regeneration. In this study, polylactic-co-glycolic acid (PLGA) plus collagen or fibrin was evaluated for its suitability as a scaffold for urinary bladder construct. Human adipose-derived stem cells (HADSCs) were cultured, followed by incubation in smooth muscle cells differentiation media. Differentiated HADSCs were then seeded onto PLGA mesh supported with collagen or fibrin. Evaluation of cell-seeded PLGA composite immersed in culture medium was performed under a light and scanning microscope. To determine if the composite is compatible with the urodynamic properties of urinary bladder, porosity and leaking test was performed. The PLGA samples were subjected to tensile testing was pulled until PLGA fibers break. The results showed that the PLGA composite is biocompatible to differentiated HADSCs. PLGA-collagen mesh appeared to be optimal as a cell carrier while the three-layered PLGA-fibrin composite is better in relation to its leaking/ porosity property. A biomechanical test was also performed for three-layered PLGA with biological adhesive and three-layered PLGA alone. The tensile stress at failure was 30.82 ± 3.80 (MPa) and 34.36 ± 2.57 (MPa), respectively. Maximum tensile strain at failure was 19.42 ± 2.24 (mm) and 23.06 ± 2.47 (mm), respectively. Young's modulus was 0.035 ± 0.0083 and 0.043 ± 0.012, respectively. The maximum load at break was 58.55 ± 7.90 (N) and 65.29 ± 4.89 (N), respectively. In conclusion, PLGA-Fibrin fulfils the criteria as a scaffold for urinary bladder reconstruction.
    Matched MeSH terms: Coated Materials, Biocompatible/chemistry*
  7. Miswan Z, Lukman SK, Abd Majid FA, Loke MF, Saidin S, Hermawan H
    Int J Pharm, 2016 Dec 30;515(1-2):460-466.
    PMID: 27793709 DOI: 10.1016/j.ijpharm.2016.10.056
    Active ingredients of ginsenoside, Rg1 and Re, are able to inhibit the proliferation of vascular smooth muscle cells and promote the growth of vascular endothelial cells. These capabilities are of interest for developing a novel drug-eluting stent to potentially solve the current problem of late-stent thrombosis and poor endotheliazation. Therefore, this study was aimed to incorporate ginsenoside into degradable coating of poly(lactic-co-glycolic acid) (PLGA). Drug mixture composed of ginseng extract and 10% to 50% of PLGA (xPLGA/g) was coated on electropolished stainless steel 316L substrate by using a dip coating technique. The coating was characterized principally by using attenuated total reflectance-Fourier transform infrared spectroscopy, scanning electron microscopy and contact angle analysis, while the drug release profile of ginsenosides Rg1 and Re was determined by using mass spectrometry at a one month immersion period. Full and homogenous coating coverage with acceptable wettability was found on the 30PLGA/g specimen. All specimens underwent initial burst release dependent on their composition. The 30PLGA/g and 50PLGA/g specimens demonstrated a controlled drug release profile having a combination of diffusion- and swelling-controlled mechanisms of PLGA. The study suggests that the 30PLGA/g coated specimen expresses an optimum composition which is seen as practicable for developing a controlled release drug-eluting stent.
    Matched MeSH terms: Coated Materials, Biocompatible/chemistry
  8. Rosenberg M, Waliszewski M, Chin K, Ahmad WAW, Caramanno G, Milazzo D, et al.
    Catheter Cardiovasc Interv, 2019 02 01;93(2):181-188.
    PMID: 30280482 DOI: 10.1002/ccd.27724
    OBJECTIVES: This prospective, observational all-comers registry assessed the safety and efficacy of a Drug Coated Balloon-only strategy (DCB-only) in patients with coronary lesions.

    BACKGROUND: Data regarding the performance of a DCB-only approach, especially in patients with previously untreated de-novo coronary artery disease (CAD), are still limited.

    METHODS: This study was conducted as an international, multicenter registry primarily enrolling patients with de-novo CAD. However, it was also possible to include patients with in-stent restenosis (ISR). The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) after 9 months.

    RESULTS: A total of 1,025 patients with a mean age of 64.0 ± 11.2 years were enrolled. The majority of treated lesions were de-novo (66.9%), followed by drug-eluting-stent ISR (DES-ISR; 22.6%) and bare-metal-stent ISR (BMS-ISR; 10.5%). The TLR rate was lower in the de-novo group (2.3%) when compared to BMS- (2.9%) and DES-ISR (5.8%) (P = 0.049). Regarding MACE, there was a trend toward fewer events in the de-novo group (5.6%) than in the BMS- (7.8%) and DES-ISR cohort (9.6%) (P = 0.131). Subgroup analyses revealed that lesion type (95% CI 1.127-6.587); P = 0.026) and additional stent implantation (95% CI 0.054-0.464; P = 0.001) were associated with higher TLR rates.

    CONCLUSIONS: Our results show that DCB-only angioplasty of de-novo coronary lesions is associated with low MACE and TLR rates. Thus, DCBs appear to be an attractive alternative for the interventional, stentless treatment of suitable de-novo coronary lesions.

    Matched MeSH terms: Coated Materials, Biocompatible*
  9. Hosseini S, Azari P, Farahmand E, Gan SN, Rothan HA, Yusof R, et al.
    Biosens Bioelectron, 2015 Jul 15;69:257-64.
    PMID: 25765434 DOI: 10.1016/j.bios.2015.02.034
    Electrospun polyhydroxybutyrate (PHB) fibers were dip-coated by polymethyl methacrylate-co-methacrylic acid, poly(MMA-co-MAA), which was synthesized in different molar ratios of the monomers via free-radical polymerization. Fabricated platfrom was employed for immobilization of the dengue antibody and subsequent detection of dengue enveloped virus in enzyme-linked immunosorbent assay (ELISA). There is a major advantage for combination of electrospun fibers and copolymers. Fiber structre of electrospun PHB provides large specific surface area available for biomolecular interaction. In addition, polymer coated parts of the platform inherited the premanent presence of surface carboxyl (-COOH) groups from MAA segments of the copolymer which can be effectively used for covalent and physical protein immobilization. By tuning the concentration of MAA monomers in polymerization reaction the concentration of surface -COOH groups can be carefully controlled. Therefore two different techniques have been used for immobilization of the dengue antibody aimed for dengue detection: physical attachment of dengue antibodies to the surface and covalent immobilization of antibodies through carbodiimide chemistry. In that perspective, several different characterization techniques were employed to investigate the new polymeric fiber platform such as scanning electron microscopy (SEM), atomic force microscopy (AFM), water contact angle (WCA) measurement and UV-vis titration. Regardless of the immobilization techniques, substantially higher signal intensity was recorded from developed platform in comparison to the conventional ELISA assay.
    Matched MeSH terms: Coated Materials, Biocompatible/chemical synthesis
  10. Dorniani D, Kura AU, Hussein-Al-Ali SH, Bin Hussein MZ, Fakurazi S, Shaari AH, et al.
    ScientificWorldJournal, 2014;2014:416354.
    PMID: 24737969 DOI: 10.1155/2014/416354
    The efficacy of two nanocarriers polyethylene glycol and polyvinyl alcohol magnetic nanoparticles coated with gallic acid (GA) was accomplished via X-ray diffraction, infrared spectroscopy, magnetic measurements, thermal analysis, and TEM. X-ray diffraction and TEM results showed that Fe3O4 nanoparticles were pure iron oxide having spherical shape with the average diameter of 9 nm, compared with 31 nm and 35 nm after coating with polyethylene glycol-GA (FPEGG) and polyvinyl alcohol-GA (FPVAG), respectively. Thermogravimetric analyses proved that after coating the thermal stability was markedly enhanced. Magnetic measurements and Fourier transform infrared (FTIR) revealed that superparamagnetic iron oxide nanoparticles could be successfully coated with two polymers (PEG and PVA) and gallic acid as an active drug. Release behavior of gallic acid from two nanocomposites showed that FPEGG and FPVAG nanocomposites were found to be sustained and governed by pseudo-second-order kinetics. Anticancer activity of the two nanocomposites shows that the FPEGG demonstrated higher anticancer effect on the breast cancer cell lines in almost all concentrations tested compared to FPVAG.
    Matched MeSH terms: Coated Materials, Biocompatible/toxicity
  11. Lo TS, Tan YL, Khanuengkitkong S, Dass AK, Cortes EF, Wu PY
    J Minim Invasive Gynecol, 2014 Sep-Oct;21(5):753-61.
    PMID: 24607796 DOI: 10.1016/j.jmig.2014.02.013
    STUDY OBJECTIVE: To assess the morphologic features of anterior armed transobturator collagen-coated polypropylene mesh and its clinical outcomes in pelvic reconstructive surgery to treat pelvic organ prolapse.
    DESIGN: Evidence obtained from several timed series with intervention (Canadian Task Force classification II-3).
    SETTING: Chang Gung Memorial Hospital, Taoyuan, Taiwan, China.
    PATIENTS: Between April 2010 and October 2012, 70 patients underwent surgery to treat symptomatic pelvic organ prolapse, stage III/IV according to the POP-Q (Pelvic Organ Quantification System).
    INTERVENTION: Anterior armed transobturator collagen-coated mesh.
    MEASUREMENT AND MAIN RESULTS: Morphologic findings and clinical outcome were measured. Morphologic features were assessed via 2-dimensional introital ultrasonography and Doppler studies. Clinical outcome was measured via subjective and objective outcome. Objective outcome was assessed via the 9-point site-specific staging method of the International Continence Society Pelvic Organ Prolapse Quantification before the operation and at 1-year postoperative follow-up. Subjective outcome was based on 4 validated questionnaires: the 6-item UDI-6 (Urogenital Distress Inventory), the 7-item IIQ-7 (Incontinence Impact Questionnaire), the 6-item POPDI-6 (Pelvic Organ Prolapse Distress Inventory 6), and the 12-item PISQ-12 (Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire), at baseline and at 12 months after the operation. Data were obtained for 65 patients who underwent the combined surgery and were able to comply with follow-up for >1 year. Ultrasound studies reveal that mesh length tends to shorten and decrease in thickness over the 1-year follow-up. Vagina thickness also was reduced. Neovascularization through the mesh was observed in <8.5% of patients in the first month and at 1 year, and was evident in approximately 83%. The mesh exposure rate was 6.4%. The recorded objective cure was 90.8% (59 of 65 patients), and subjective cure was 89.2% (58 of 65 patients) at mean (SD) follow-up of 19.40 (10.98) months. At 2 years, UDI-6, IIQ-7, and POPDI-6 scores were all significantly decreased (p < .001), whereas the PISQ-12 score was significantly increased (p = .01).
    CONCLUSIONS: Ultrasound features suggest that the degeneration of collagen barrier may be longer than expected and that integration of collagen-coated mesh could occur up to 1 year. A substantially good clinical outcome was noted.
    KEYWORDS: Anterior vaginal mesh; Collagen-coated mesh; Morphology; Outcome; Pelvic organ prolapse
    Matched MeSH terms: Coated Materials, Biocompatible/chemistry
  12. Chin K
    EuroIntervention, 2011 May;7 Suppl K:K43-6.
    PMID: 22027726 DOI: 10.4244/EIJV7SKA7
    In-stent restenosis remains an important issue even in the drug-eluting stent (DES) era today. In recent years, drug-eluting balloons (DEB) have emerged as a potential alternative to the treatment of in-stent restenosis. Paclitaxel was identified as the primary drug for DEB because of its rapid uptake and prolonged retention. Non-stent-based local drug delivery using DEB maintains the antiproliferation properties of DES, but without the limitations of DES such as subacute stent thrombosis, stent fractures, prolonged antiplatelet therapy and more importantly, avoiding a "stent-in-a-stent" approach. The first major impact of drug-eluting balloon (DEB) in the management of bare metal instent restenosis was the "PACCOCATH ISR I" randomised trial, comparing the efficacy of drug-eluting balloon versus uncoated balloon. The six months angiographic results showed a binary restenosis of 5% and 4% MACE in the drug-eluting balloon group, compared with 43% binary restenosis and 31% MACE, in the uncoated balloon group (p=0.002 and 0.02). The second major DEB trial is the "PEPCAD II Trial", comparing the efficacy of the SeQuent Please DEB with the Taxus drug-eluting stent in the treatment of bare-metal stent instent restenosis. At 6-month follow-up, in-segment late lumen loss was 0.38 ± 0.61 mm in the DES group versus 0.17 ± 0.42 mm (p=0.03) in the DEB group, resulting in a binary restenosis rate of 12/59 (20%) versus 4/57 (7%; p=0.06). At 12 months, MACE rates were 22% in the Taxus group and 9% in the DEB group (P=0.08). The TLR at 12 months was 15% in the Taxus group and 6% in the DEB group (p=0.15). Based on these two pivotal trials, the European Society of Cardiology Guidelines for Percutaneous Coronary Intervention (2010) recommended that DEB should be considered for the treatment of in-stent restenosis after prior bare-metal stent. This was accorded a class 2 IIa indication, with a level B evidence.
    Matched MeSH terms: Coated Materials, Biocompatible*
  13. Lau CP, Chee EK, Thirumal M
    Med J Malaysia, 2006 Dec;61 Suppl B:32-6.
    PMID: 17600990
    Antibiotic pouch technique is commonly used due to the high local antibiotic concentration and moist environment for wound healing. We used locally made gentamicin impregnated Plaster of Paris discs in treating wounds with exposed deep structures like tendons and bones. Out of 22 patients treated with this method, 19 completed treatment. Granulation tissue formed quickly and effectively covered the exposed structures. All wounds either healed by secondary intention or became suitable for split skin grafting. Gentamicin impregnated Plaster of Paris disc pouch dressing is safe, cost saving, and effective for management of deep open wounds.
    Matched MeSH terms: Coated Materials, Biocompatible*
  14. Isa ZM, Schneider GB, Zaharias R, Seabold D, Stanford CM
    Int J Oral Maxillofac Implants, 2006 Mar-Apr;21(2):203-11.
    PMID: 16634490
    PURPOSE: The objective of this study was to test the hypothesis that fluoride-modified titanium surfaces would enhance osteoblast differentiation. Osteoblast growth on a moderately rough etched fluoride-modified titanium surface (alteration in cellular differentiation) was compared to osteoblast growth on the same surface grit-blasted with titanium dioxide. The potential role of nanometer-level alterations on cell shape and subsequent differentiation was then compared.
    MATERIALS AND METHODS: Human embryonic palatal mesenchymal (HEPM) cultures were incubated on the respective surfaces for 1, 3, and 7 days, followed by analysis for cell proliferation, alkaline phosphatase (ALP) -specific activity, and mRNA steady-state expression for bone-related genes (ALP, type I collagen, osteocalcin, bone sialoprotein [BSP] II, Cbfa1, and osterix) by real-time polymerase chain reaction (PCR).
    RESULTS: The different surfaces did not alter the mRNA expression for ALP, type I collagen, osterix, osteocalcin, or BSP II. However, Cbfa1 expression on the fluoride-modified titanium surface was significantly higher (P < .001) at 1 week. The number of cells on this surface was 20% lower than the number of cells on the surface TiO2-blasted with 25-microm particles but not significantly different from the number of cells on the surface TiO2-blasted with 125-microm particles. Cells grown on all the titanium surfaces expressed similar levels of ALP activity.
    CONCLUSIONS: The results indicated that a fluoride-modified surface topography, in synergy with surface roughness, may have a greater influence on the level of expression of Cbfa1 (a key regulator for osteogenesis) than the unmodified titanium surfaces studied.
    Matched MeSH terms: Coated Materials, Biocompatible/pharmacology
  15. Haseeb A, Ajit Singh V, Teh CSJ, Loke MF
    J Orthop Surg (Hong Kong), 2019 5 30;27(2):2309499019850324.
    PMID: 31138005 DOI: 10.1177/2309499019850324
    BACKGROUND: Ceftaroline is a cephalosporin that is effective against methicillin-resistant Staphylococcus aureus (MRSA) infections. The objective of this study was to determine the feasibility of using ceftaroline-loaded Polymethyl methacrylate (PMMA) as antibiotic cement against MRSA versus vancomycin-loaded PMMA in an in vitro setting.

    METHODS: PMMA pellets were prepared with three separate concentrations of each of the two antibiotics tested. They were tested to determine the effect of increasing concentration of antibiotics on the biomechanical properties of PMMA and antibiotic activity by measuring the zone of inhibition and broth elution assay.

    RESULTS: Ceftaroline PMMA at 3 wt%, three-point bending was 37.17 ± 0.51 N ( p < 0.001) and axial loading was 41.95 N ± 0.51 ( p < 0.001). At 5-wt% vancomycin-PMMA, three-point bending was 41.65 ± 0.79 N ( p = 0.02) and axial loading was 49.49 ± 2.21 N ( p = 0.01). Stiffness of ceftroline-loaded PMMA in low and medium concentration was significantly higher than the vancomycin. The zone of inhibition for ceftaroline was higher than vancomycin. Ceftaroline at 3 wt% eluted up to 6 weeks (0.3 ± 0.1 μg/ml) above the minimum inhibitory concentration (MIC) and vancomycin at 2.5 wt% eluted up to 3 weeks, same as MIC, that is, 0.5 ± 0.0 μg/ml.

    CONCLUSIONS: Ceftaroline, loaded at similar concentrations as vancomycin into PMMA, is a more potent alternative based on its more favourable bioactivity and elution properties, while having a lesser effect on the mechanical properties of the cement. The use of 3-wt% ceftaroline as antibiotic laden PMMA against MRSA is recommended. It should be noted that this was an in vitro study and to determine the clinical efficacy would need prospective, controlled and randomized studies.

    Matched MeSH terms: Coated Materials, Biocompatible*
  16. Bakhsheshi-Rad HR, Ismail AF, Aziz M, Akbari M, Hadisi Z, Khoshnava SM, et al.
    Mater Sci Eng C Mater Biol Appl, 2020 Jun;111:110812.
    PMID: 32279830 DOI: 10.1016/j.msec.2020.110812
    Magnesium (Mg) alloys present great potential for the development of orthopedic implants, whereas, their high degradation rate and poor antibacterial performance have restricted orthopedic applications. In this work, PLLA/GO-AgNP (poly-L-lactic acid/graphene oxide- silver nanoparticle) with different concentration of GO-AgNPs were deposited on Mg alloy via electrospinning method for enhancement of corrosion resistance and antibacterial performance. The result revealed that incorporation of GO into PLLA fibrous considerably slowed down the degradation rate of Mg alloy substrate and reduced the H2 release rate from the substrate. Also, co-incorporation of GO and AgNPs into PLLA fibrous resulted in substantial escalate in compressive strength after immersion in simulated body fluid (SBF). Antibacterial activity test exhibited that Mg alloy and neat PLLA fibrous presented minimal inhibition area toward Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus). In contrast, using PLLA/GO-AgNPs fibrous improved antibacterial performance against both bacteria. Cytocompatibility results indicated that PLLA/GO-AgNPs fibrous with a low amount of GO-AgNPs enhanced cell proliferation and growth while high co-incorporation of GO-AgNPs showed a negative effect on cell proliferation. Taken together, PLLA/1GO-AgNPs fibrous coating shows suitable corrosion resistance, cytocompatibility, and antibacterial function for use in orthopedic applications.
    Matched MeSH terms: Coated Materials, Biocompatible/pharmacology*
  17. Khalajabadi SZ, Abu ABH, Ahmad N, Yajid MAM, Hj Redzuan NB, Nasiri R, et al.
    J Mech Behav Biomed Mater, 2018 Jan;77:360-374.
    PMID: 28985616 DOI: 10.1016/j.jmbbm.2017.09.032
    This study was aimed to improve of the corrosion resistance and mechanical properties of Mg/15TiO2/5HA nanocomposite by silicon and magnesium oxide coatings prepared using a powder metallurgy method. The phase evolution, chemical composition, microstructure and mechanical properties of uncoated and coated samples were characterized. Electrochemical and immersion tests used to investigate the in vitro corrosion behavior of the fabricated samples. The adhesion strength of ~36MPa for MgO and ~32MPa for Si/MgO coatings to substrate was measured by adhesion test. Fabrication a homogenous double layer coating with uniform thicknesses consisting micro-sized particles of Si as outer layer and flake-like particles of MgO as the inner layer on the surface of Mg/15TiO2/5HA nanocomposite caused the corrosion resistance and ductility increased whereas the ultimate compressive stress decreased. However, after immersion in SBF solution, Si/MgO-coated sample indicates the best mechanical properties compared to those of the uncoated and MgO-coated samples. The increase of cell viability percentage of the normal human osteoblast (NHOst) cells indicates the improvement in biocompatibility of Mg/15TiO2/5HA nanocomposite by Si/MgO coating.
    Matched MeSH terms: Coated Materials, Biocompatible/chemistry*
  18. Her AY, Shin ES, Bang LH, Nuruddin AA, Tang Q, Hsieh IC, et al.
    Cardiol J, 2021;28(1):136-149.
    PMID: 31565793 DOI: 10.5603/CJ.a2019.0093
    Coronary artery disease (CAD) is currently the leading cause of death globally, and the prevalence of this disease is growing more rapidly in the Asia-Pacific region than in Western countries. Although the use of metal coronary stents has rapidly increased thanks to the advancement of safety and efficacy of newer generation drug eluting stent (DES), patients are still negatively affected by some the inherent limitations of this type of treatment, such as stent thrombosis or restenosis, including neoatherosclerosis, and the obligatory use of dual antiplatelet therapy (DAPT) with unknown optimal duration. Drug-coated balloon (DCB) treatment is based on a leave-nothing-behind concept and therefore it is not limited by stent thrombosis and long-term DAPT; it directly delivers an anti-proliferative drug which is coated on a balloon after improving coronary blood flow. At present, DCB treatment is recommended as the first-line treatment option in metal stent-related restenosis linked to DES and bare metal stent. For de novo coronary lesions, the application of DCB treatment is extended further, for conditions such as small vessel disease, bifurcation lesions, and chronic total occlusion lesions, and others. Recently, several reports have suggested that fractional flow reserve guided DCB application was safe for larger coronary artery lesions and showed good long-term outcomes. Therefore, the aim of these recommendations of the consensus group was to provide adequate guidelines for patients with CAD based on objective evidence, and to extend the application of DCB to a wider variety of coronary diseases and guide their most effective and correct use in actual clinical practice.
    Matched MeSH terms: Coated Materials, Biocompatible
  19. Khalaf S, Ariffin Z, Husein A, Reza F
    J Prosthodont, 2017 Dec;26(8):664-669.
    PMID: 28177575 DOI: 10.1111/jopr.12460
    PURPOSE: To compare the adhesion of three microorganisms on modified and unmodified silicone elastomer surfaces with different surface roughnesses and porosities.

    MATERIALS AND METHODS: Candida albicans, Streptococcus mutans, and Staphylococcus aureus were incubated with modified and unmodified silicone groups (N = 35) for 30 days at 37°C. The counts of viable microorganisms in the accumulating biofilm layer were determined and converted to cfu/cm2 unit surface area. A scanning electron microscope (SEM) was used to evaluate the microbial adhesion. Statistical analysis was performed using t-test, one-way ANOVA, and post hoc tests as indicated.

    RESULTS: Significant differences in microbial adhesion were observed between modified and unmodified silicone elastomers after the cells were incubated for 30 days (p < 0.001). SEM showed evident differences in microbial adhesion on modified silicone elastomer compared with unmodified silicone elastomer.

    CONCLUSIONS: Surface modification of silicone elastomer yielding a smoother and less porous surface showed lower adhesion of different microorganisms than observed on unmodified surfaces.

    Matched MeSH terms: Coated Materials, Biocompatible
  20. Ali RM, Degenhardt R, Zambahari R, Tresukosol D, Ahmad WA, Kamar Hb, et al.
    EuroIntervention, 2011 May;7 Suppl K:K83-92.
    PMID: 22027736 DOI: 10.4244/EIJV7SKA15
    Coronary lesions in diabetics (DM) are associated with a high recurrence following percutaneous coronary intervention (PCI), even after drug-eluting stent (DES) deployment. Encouraging clinical data of the drug-eluting balloon catheter (DEB) SeQuent Please warrant its investigation in these patients.
    Matched MeSH terms: Coated Materials, Biocompatible*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links