Displaying publications 41 - 60 of 368 in total

Abstract:
Sort:
  1. Wong XY, Quesada-González D, Manickam S, Muthoosamy K
    Anal Chim Acta, 2021 Aug 29;1175:338745.
    PMID: 34330444 DOI: 10.1016/j.aca.2021.338745
    Metal ions homeostasis plays an important role in biological processes. The ability to detect the concentration of metal ions in biological fluids is often challenged by the obvious interference or competitive binding nature of other alkaline metals ions. Common analytical techniques employed for metal ions detection are electrochemical, fluorescence and colorimetric methods. However, most reported metal ions sensors are complicated, time-consuming and involve costly procedures with limited effectiveness. Herein, a nanobiosensor for detecting sodium and potassium ions using folic acid-functionalised reduced graphene oxide-modified RNase A gold nanoclusters (FA-rGO-RNase A/AuNCs) based on fluorescence "turn-off/turn-on" is presented. Firstly, a facile and optimised protocol for the fabrication of RNase A/AuNCs is developed. The activity of RNase A protein after the formation of RNase A/AuNCs is studied. RNase A/AuNCs is then loaded onto FA-rGO, in which FA-rGO is used as a potential carrier and fluorescence quencher for RNase A/AuNCs. Finally, a fluorescence "turn-on" sensing strategy is developed using the as-synthesised FA-rGO-RNase A/AuNCs to detect sodium and potassium ions. The developed nanobiosensor revealed an excellent sensing performance and meets the sensitivity required to detect both sodium and potassium ions. To the best of our knowledge, this is the first work done on determining the RNase A protein activity in RNase A/AuNCs and exploring the potential application of RNase A/AuNCs as a metal ion sensor. This work serves as a proof-of-concept for combining the potential of drug delivery, active targeting and therapy on cancer cells, as well as biosensing of metal ions into a single platform.
    Matched MeSH terms: Biosensing Techniques*
  2. Ng CL, Reaz MBI, Crespo ML, Cicuttin A, Chowdhury MEH
    Sci Rep, 2020 09 10;10(1):14891.
    PMID: 32913303 DOI: 10.1038/s41598-020-71709-0
    A capacitive electromyography (cEMG) biomedical sensor measures the EMG signal from human body through capacitive coupling methodology. It has the flexibility to be insulated by different types of materials. Each type of insulator will yield a unique skin-electrode capacitance which determine the performance of a cEMG biomedical sensor. Most of the insulator being explored are solid and non-breathable which cause perspiration in a long-term EMG measurement process. This research aims to explore the porous medical bandages such as micropore, gauze, and crepe bandage to be used as an insulator of a cEMG biomedical sensor. These materials are breathable and hypoallergenic. Their unique properties and characteristics have been reviewed respectively. A 50 Hz digital notch filter was developed and implemented in the EMG measurement system design to further enhance the performance of these porous medical bandage insulated cEMG biomedical sensors. A series of experimental verifications such as noise floor characterization, EMG signals measurement, and performance correlation were done on all these sensors. The micropore insulated cEMG biomedical sensor yielded the lowest noise floor amplitude of 2.44 mV and achieved the highest correlation coefficient result in comparison with the EMG signals captured by the conventional wet contact electrode.
    Matched MeSH terms: Biosensing Techniques*
  3. Taniselass S, Arshad MKM, Gopinath SCB
    Biosens Bioelectron, 2019 Apr 01;130:276-292.
    PMID: 30771717 DOI: 10.1016/j.bios.2019.01.047
    Graphene is a 2-dimensional nanomaterial with an atomic thickness has attracted a strong scientific interest owing to their remarkable optical, electronic, thermal, mechanical and electrochemical properties. Graphene-based materials particularly graphene oxide and reduced graphene oxide are widely utilized in various applications ranging from food industry, environmental monitoring and biomedical fields as well as in the development of various types of biosensing devices. The richness in oxygen functional groups in the materials serves as a catalysis for the development of biosensors/electrochemical biosensors which promotes for an attachment of biological recognition elements, surface functionalization and compatible with micro- and nano- bio-environment. In this review, the graphene-based materials application in electrochemical biosensors based on recent advancement (e.g; the surface modification and analytical performances) and the utilization of such biosensors to monitor the noncommunicable diseases are presented. The detection performances of the graphene-based electrochemical biosensors are in the range of ng/mL and have reached up to fg/mL in detecting the targets of NCDs with higher selectivity, sensitivity and stability with good reproducibility attributes. We have discussed the advances while addressing the very specific biomarkers for the NCDs detection. Challenges and possible future research directions for the NCDs detection based on graphene nanocomposite with other 2D nanomaterials are outlined.
    Matched MeSH terms: Biosensing Techniques*
  4. Alkhadher SAA, Kadir AA, Zakaria MP, Al-Gheethi A, Asghar BHM
    Mar Pollut Bull, 2020 May;154:111115.
    PMID: 32319929 DOI: 10.1016/j.marpolbul.2020.111115
    The current study aimed to develop a suitable molecular marker [Linear alkylbenzenes (LABs)] approach for pollution determination in mangrove oysters of peninsular Malaysia. C. belcheri species were collected from rivers of Merbok, Perai, Klang, Muar and PulauMerambong (An Island). The LABs were extracted from C. belcheri and determined using GC-MS. The LABs indices which included I/E, L/S and C13/C12 were applied to describe the sources and biodegradation of LABs. The results revealed that the maximum concentrations were detected in oysters from Klang (27.91 ng g-1dw), while the lowest concentrations were detected in oysters from Merbok (8.12 ng g-1dw). Moreover, I/E ratios varied between 2.83 and 6.40, indicating the secondary treatment effluents being discharged to coastal zones. The results of this study suggested that the oysters absorbed LABs mainly in dissolved phase. Therefore, mangrove oysters are a good biosensor for LABs contamination in the aquatic environment.
    Matched MeSH terms: Biosensing Techniques*
  5. Khalil I, Hashem A, Nath AR, Muhd Julkapli N, Yehye WA, Basirun WJ
    Mol Cell Probes, 2021 10;59:101758.
    PMID: 34252563 DOI: 10.1016/j.mcp.2021.101758
    Authentication, detection and quantification of ingredients, and adulterants in food, meat, and meat products are of high importance these days. The conventional techniques for the detection of meat species based on lipid, protein and DNA biomarkers are facing challenges due to the poor selectivity, sensitivity and unsuitability for processed food products or complex food matrices. On the other hand, DNA based molecular techniques and nanoparticle based DNA biosensing strategies are gathering huge attention from the scientific communities, researchers and are considered as one of the best alternatives to the conventional strategies. Though nucleic acid based molecular techniques such as PCR and DNA sequencing are getting greater successes in species detection, they are still facing problems from its point-of-care applications. In this context, nanoparticle based DNA biosensors have gathered successes in some extent but not to a satisfactory stage to mark with. In recent years, many articles have been published in the area of progressive nucleic acid-based technologies, however there are very few review articles on DNA nanobiosensors in food science and technology. In this review, we present the fundamentals of DNA based molecular techniques such as PCR, DNA sequencing and their applications in food science. Moreover, the in-depth discussions of different DNA biosensing strategies or more specifically electrochemical and optical DNA nanobiosensors are presented. In addition, the significance of DNA nanobiosensors over other advanced detection technologies is discussed, focusing on the deficiencies, advantages as well as current challenges to ameliorate with the direction for future development.
    Matched MeSH terms: Biosensing Techniques*
  6. Chen TY, Mani V, Huang ST, Chang PC, Huang CH, Huang NM
    Anal Chim Acta, 2017 Oct 16;990:78-83.
    PMID: 29029745 DOI: 10.1016/j.aca.2017.08.051
    An electrochemical latent redox probe, SAF 5 was designed, synthesized and characterized. A rapid and sensitive solution-based assay was demonstrated for salicylate hydroxylase (SHL). In presence of NADH at aerobic conditions, SHL catalyzed the decarboxylative hydroxylation of SAF and released a redox reporter amino ferrocene (AF 6). The release of AF 6 was monitored at interference free potential region (-50 mV vs. Ag|AgCl) using differential pulse voltammetry as signal read-out. The current signal generated by this process is highly specific, and insensitive to other biological interfering compounds. Next, the SAF incorporated SHL assay was extended to fabricate immobilization-free biosensors for rapid sensing of salicylic acid (SA) and β-hydroxybutyrate (β-HB) in whole blood. The described method rapidly detects SA in a linear range of 35-560 μM with detection limit of 5.0 μM. For β-HB determination, the linear range was 10-600 μM and detection limit was 2.0 μM. Besides, the assay protocols are simple, fast, reliable, selective, sensitive and advantageous over existing methods. The whole blood assay did not required cumbersome steps such as, enzyme immobilization, pre-treatments and holds great practical potential in clinical diagnosis.
    Matched MeSH terms: Biosensing Techniques*
  7. Alahnomi RA, Zakaria Z, Ruslan E, Ab Rashid SR, Mohd Bahar AA, Shaaban A
    PLoS One, 2017;12(9):e0185122.
    PMID: 28934301 DOI: 10.1371/journal.pone.0185122
    A novel symmetrical split ring resonator (SSRR) based microwave sensor with spurline filters for detecting and characterizing the properties of solid materials has been developed. Due to the weak perturbation in the interaction of material under test (MUT) and planar microwave sensor, spurline filters were embedded to the SSRR microwave sensor which effectively enhanced Q-factor with suppressing the undesired harmonic frequency. The spurline filter structures force the presented sensor to resonate at a fundamental frequency of 2.2 GHz with the capabilities of suppressing rejected harmonic frequency and miniaturization in circuit size. A wide bandwidth rejection is achieved by using double spurlines filters with high Q-factor achievement (up to 652.94) compared to single spurline filter. The new SSRR sensor with spurline filters displayed desired properties such as high sensitivity, accuracy, and performance with a 1.3% typical percentage error in the measurement results. Furthermore, the sensor has been successfully applied for detecting and characterizing solid materials (such as Roger 5880, Roger 4350, and FR4) and evidently demonstrated that it can suppress the harmonic frequency effectively. This novel design with harmonic suppression is useful for various applications such as food industry (meat, fruit, vegetables), biological medicine (derived from proteins and other substances produced by the body), and Therapeutic goods (antiseptics, vitamins, anti-psychotics, and other medicines).
    Matched MeSH terms: Biosensing Techniques/instrumentation*
  8. Azizi MMF, Romeli S, Razali H, Ariffin EY, Tajol Ariffin MA, Heng LY, et al.
    Sci Rep, 2022 Nov 11;12(1):19324.
    PMID: 36369187 DOI: 10.1038/s41598-022-20998-8
    More than 200 different cultivars of durian exist worldwide but Durio zibethinus or Musang King (MK) is the most premium and prized durian fruit among the recommended varieties. Early identification of this premium variety is critical to protect from non-authentic MK durian cultivars. However, the MK variety's morphological traits are nearly identical to other varieties. Currently, the identification of durian varieties is mostly performed via evaluation of leaf shape, fruit shape, aroma, taste and seed shape and this requires trained personnel for the morphology observation. To enable the rapid identification of the MK variety, PCR amplification of ten durian varieties using six gene candidates from the chloroplast genome was first performed to obtain DNA probes that were specific to the MK durian variety. PCR amplification of ten durian varieties using primers designed confirmed that the nadhA gene sequence showed an obvious difference in the MK variety from other durian varieties. The unique sequence of MK was used as a DNA probe to develop an electrochemical biosensor for the direct identification of the MK durian variety. The electrochemical biosensor was based on the hybridization response of the immobilized DNA probe with the target DNA from the MK variety and was monitored via differential pulse voltammetry technique. Under optimal conditions, the DNA electrochemical biosensor showed a low detection limit at 10% of MK genomic DNA concentration with a wide linear calibration range of 0.05-1.5 µM (R2 = 0.9891) and RSD value of 3.77% (n = 3). The results of the developed DNA biosensor provide high promise for the development of portable sensors employed in the determination of MK variety in the field.
    Matched MeSH terms: Biosensing Techniques*
  9. Zhao X, Gopinath SCB, Zhao W
    Biotechnol Appl Biochem, 2023 Apr;70(2):502-508.
    PMID: 35661417 DOI: 10.1002/bab.2372
    Abdominal aortic aneurysm (AAA), a medical complication, occurs when the aortic area becomes swollen and very large. It is mandatory to identify AAA to avoid the breakdown of aneurysms. C-reactive protein (CRP) has been recognized as one of the biomarkers for identifying AAA due to the possibility of CRP produced in vascular tissue, which contributes to the formation of an aneurysm, and it is elevated in patients with a ruptured AAA. This research work was designed to develop an immunosensor on a multiwalled carbon nanotube (MWCNT)-modified surface to quantify the CRP level. Anti-CRP specificity was constructed on the MWCNT surface through a silane linker to interact with CRP. The detection limit of CRP was calculated as 100 pM with an R2 (determination coefficient) value of 0.9855 (y = 2.3446x - 1.9922) on a linear regression graph. The dose-dependent linear pattern was registered from 200 to 3000 pM and attained the saturation level during binding at 3000 pM. Furthermore, serum-spiked CRP showed a clear increase in the current response, proving the specific recognition of CRP in biological samples. This designed biosensor identifies CRP at a lower level and can help diagnose AAA.
    Matched MeSH terms: Biosensing Techniques*
  10. Meliana C, Liu J, Show PL, Low SS
    Bioengineered, 2024 Dec;15(1):2310908.
    PMID: 38303521 DOI: 10.1080/21655979.2024.2310908
    The burden of food contamination and food wastage has significantly contributed to the increased prevalence of foodborne disease and food insecurity all over the world. Due to this, there is an urgent need to develop a smarter food traceability system. Recent advancements in biosensors that are easy-to-use, rapid yet selective, sensitive, and cost-effective have shown great promise to meet the critical demand for onsite and immediate diagnosis and treatment of food safety and quality control (i.e. point-of-care technology). This review article focuses on the recent development of different biosensors for food safety and quality monitoring. In general, the application of biosensors in agriculture (i.e. pre-harvest stage) for early detection and routine control of plant infections or stress is discussed. Afterward, a more detailed advancement of biosensors in the past five years within the food supply chain (i.e. post-harvest stage) to detect different types of food contaminants and smart food packaging is highlighted. A section that discusses perspectives for the development of biosensors in the future is also mentioned.
    Matched MeSH terms: Biosensing Techniques*
  11. Kausar AS, Reza AW, Latef TA, Ullah MH, Karim ME
    Sensors (Basel), 2015 Apr 15;15(4):8787-831.
    PMID: 25884787 DOI: 10.3390/s150408787
    The concept of optical antennas in physical optics is still evolving. Like the antennas used in the radio frequency (RF) regime, the aspiration of optical antennas is to localize the free propagating radiation energy, and vice versa. For this purpose, optical antennas utilize the distinctive properties of metal nanostructures, which are strong plasmonic coupling elements at the optical regime. The concept of optical antennas is being advanced technologically and they are projected to be substitute devices for detection in the millimeter, infrared, and visible regimes. At present, their potential benefits in light detection, which include polarization dependency, tunability, and quick response times have been successfully demonstrated. Optical antennas also can be seen as directionally responsive elements for point detectors. This review provides an overview of the historical background of the topic, along with the basic concepts and parameters of optical antennas. One of the major parts of this review covers the use of optical antennas in biosensing, presenting biosensing applications with a broad description using different types of data. We have also mentioned the basic challenges in the path of the universal use of optical biosensors, where we have also discussed some legal matters.
    Matched MeSH terms: Biosensing Techniques/methods*
  12. Parkash O, Shueb RH
    Viruses, 2015 Oct 19;7(10):5410-27.
    PMID: 26492265 DOI: 10.3390/v7102877
    Dengue is an arthropod-borne viral disease caused by four antigenically different serotypes of dengue virus. This disease is considered as a major public health concern around the world. Currently, there is no licensed vaccine or antiviral drug available for the prevention and treatment of dengue disease. Moreover, clinical features of dengue are indistinguishable from other infectious diseases such as malaria, chikungunya, rickettsia and leptospira. Therefore, prompt and accurate laboratory diagnostic test is urgently required for disease confirmation and patient triage. The traditional diagnostic techniques for the dengue virus are viral detection in cell culture, serological testing, and RNA amplification using reverse transcriptase PCR. This paper discusses the conventional laboratory methods used for the diagnosis of dengue during the acute and convalescent phase and highlights the advantages and limitations of these routine laboratory tests. Subsequently, the biosensor based assays developed using various transducers for the detection of dengue are also reviewed.
    Matched MeSH terms: Biosensing Techniques/methods*
  13. Yunos MFAM, Manczak R, Guines C, Mansor AFM, Mak WC, Khan S, et al.
    Biosensors (Basel), 2021 Dec 03;11(12).
    PMID: 34940251 DOI: 10.3390/bios11120494
    Diabetes has become a major health problem in society. Invasive glucometers, although precise, only provide discrete measurements at specific times and are unsuitable for long-term monitoring due to the injuries caused on skin and the prohibitive cost of disposables. Remote, continuous, self-monitoring of blood sugar levels allows for active and better management of diabetics. In this work, we present a radio frequency (RF) sensor based on a stepped impedance resonator for remote blood glucose monitoring. When placed on top of a human hand, this RF interdigital sensor allows detection of variation in blood sugar levels by monitoring the changes in the dielectric constant of the material underneath. The designed stepped impedance resonator operates at 3.528 GHz with a Q factor of 1455. A microfluidic device structure that imitates the blood veins in the human hand was fabricated in PDMS to validate that the sensor can measure changes in glucose concentrations. To test the RF sensor, glucose solutions with concentrations ranging from 0 to 240 mg/dL were injected into the fluidic channels and placed underneath the RF sensor. The shifts in the resonance frequencies of the RF sensor were measured using a network analyzer via its S11 parameters. Based on the change in resonance frequencies, the sensitivity of the biosensor was found to be 264.2 kHz/mg·dL-1 and its LOD was calculated to be 29.89 mg/dL.
    Matched MeSH terms: Biosensing Techniques*
  14. Ku Abd Rahim KN, Elamvazuthi I, Izhar LI, Capi G
    Sensors (Basel), 2018 Nov 26;18(12).
    PMID: 30486242 DOI: 10.3390/s18124132
    Increasing interest in analyzing human gait using various wearable sensors, which is known as Human Activity Recognition (HAR), can be found in recent research. Sensors such as accelerometers and gyroscopes are widely used in HAR. Recently, high interest has been shown in the use of wearable sensors in numerous applications such as rehabilitation, computer games, animation, filmmaking, and biomechanics. In this paper, classification of human daily activities using Ensemble Methods based on data acquired from smartphone inertial sensors involving about 30 subjects with six different activities is discussed. The six daily activities are walking, walking upstairs, walking downstairs, sitting, standing and lying. It involved three stages of activity recognition; namely, data signal processing (filtering and segmentation), feature extraction and classification. Five types of ensemble classifiers utilized are Bagging, Adaboost, Rotation forest, Ensembles of nested dichotomies (END) and Random subspace. These ensemble classifiers employed Support vector machine (SVM) and Random forest (RF) as the base learners of the ensemble classifiers. The data classification is evaluated with the holdout and 10-fold cross-validation evaluation methods. The performance of each human daily activity was measured in terms of precision, recall, F-measure, and receiver operating characteristic (ROC) curve. In addition, the performance is also measured based on the comparison of overall accuracy rate of classification between different ensemble classifiers and base learners. It was observed that overall, SVM produced better accuracy rate with 99.22% compared to RF with 97.91% based on a random subspace ensemble classifier.
    Matched MeSH terms: Biosensing Techniques/methods*
  15. Zheng J, Wai JL, Lake RJ, New SY, He Z, Lu Y
    Anal Chem, 2021 Aug 10;93(31):10834-10840.
    PMID: 34310132 DOI: 10.1021/acs.analchem.1c01077
    DNAzymes have emerged as an important class of sensors for a wide variety of metal ions, with florescence DNAzyme sensors as the most widely used in different sensing and imaging applications because of their fast response time, high signal intensity, and high sensitivity. However, the requirements of an external excitation light source and its associated power increase the cost and size of the fluorometer, making it difficult to be used for portable detections. To overcome these limitations, we report herein a DNAzyme sensor that relies on chemiluminescence resonance energy transfer (CRET) without the need for external light. The sensor is constructed by combining the functional motifs from both Pb2+-dependent 8-17 DNAzyme conjugated to fluorescein (FAM) and hemin/G-quadruplex that mimics horseradish peroxidase to catalyze the oxidation of luminol by H2O2 to yield chemiluminescence. In the absence of Pb2+, the hybridization between the enzyme and substrate strands bring the FAM and hemin/G-quadruplex in close proximity, resulting in CRET. The presence of Pb2+ ions can drive the cleavage on the substrate strand, resulting in a sharp decrease in the melting temperature of hybridization and thus separation of the FAM from hemin/G-quadruplex. The liberated CRET pair causes a ratiometric increase in the donor's fluorescent signal and a decrease in the acceptor signal. Using this method, Pb2+ ions have been measured rapidly (<15 min) with a low limit of detection at 5 nM. By removing the requirement of exogenous light excitation, we have demonstrated a simple and portable detection using a smartphone, making the DNAzyme-CRET system suitable for field tests of lake water. Since DNAzymes selective for other metal ions or targets, such as bacteria, can be obtained using in vitro selection, the method reported here opens a new avenue for rapid, portable, and ratiometric detection of many targets in environmental monitoring, food safety, and medical diagnostics.
    Matched MeSH terms: Biosensing Techniques*
  16. Anboo S, Lau SY, Kansedo J, Yap PS, Hadibarata T, Jeevanandam J, et al.
    Biotechnol Bioeng, 2022 Oct;119(10):2609-2638.
    PMID: 35851660 DOI: 10.1002/bit.28185
    Over the past decade, nanotechnology has been developed and employed across various entities. Among the numerous nanostructured material types, enzyme-incorporated nanomaterials have shown great potential in various fields, as an alternative to biologically derived as well as synthetically developed hybrid structures. The mechanism of incorporating enzyme onto a nanostructure depends on several factors including the method of immobilization, type of nanomaterial, as well as operational and environmental conditions. The prospects of enzyme-incorporated nanomaterials have shown promising results across various applications, such as biocatalysts, biosensors, drug therapy, and wastewater treatment. This is due to their excellent ability to exhibit chemical and physical properties such as high surface-to-volume ratio, recovery and/or reusability rates, sensitivity, response scale, and stable catalytic activity across wide operating conditions. In this review, the evolution of enzyme-incorporated nanomaterials along with their impact on our society due to its state-of-the-art properties, and its significance across different industrial applications are discussed. In addition, the weakness and future prospects of enzyme-incorporated nanomaterials were also discussed to guide scientists for futuristic research and development in this field.
    Matched MeSH terms: Biosensing Techniques*
  17. Nur Akmar Jamil, Gan SM, Burhanuddin Yeop Majlis, Susthitha Menon P
    Sains Malaysiana, 2018;47:1033-1038.
    Artikel ini menganalisis biosensor resonans plasmon permukaan (SPR) dengan lapisan grafin yang meningkatkan
    kecekapan biosensor urea kerana penerapannya yang tinggi. Tatasusunan Kretschmann merupakan teknik yang paling
    berkesan digunakan untuk pengujaan plasmon. Dalam kajian ini, kami menganalisis kesan ekalapisan MoS2 dengan
    lapisan grafin yang didepositkan pada bahan plasmon, iaitu logam emas (Au), di dalam tatasusunan ini. Simulasi untuk
    menganalisis tatasusunan ini adalah berdasarkan kepada kaedah perbezaan terhingga domain masa (FDTD). Prestasi
    biosensor SPR dapat dipantau dengan menganalisis kepekaan dan lebar penuh pada separuh maksimum (FWHM) spektrum
    SPR. Pengukuran diperhatikan pada panjang gelombang 670 nm dan 785 nm untuk pengesanan urea. Indeks molar dan
    indeks biasan berbeza (RI) daripada 1.335 sehingga 1.342 untuk lapisan penderiaan. Keputusan menunjukkan peratus
    peningkatan kepekaan biosensor Au/MoS2
    /grafin berbanding biosensor Au konvensional adalah 98% dan 202% masingmasing
    pada panjang gelombang 670 nm dan 785 nm. Ini menunjukkan bahawa cadangan biosensor SPR yang novel ini
    adalah lebih sensitif untuk pengesanan urea.
    Matched MeSH terms: Biosensing Techniques
  18. Muniandy S, Teh SJ, Thong KL, Thiha A, Dinshaw IJ, Lai CW, et al.
    Crit Rev Anal Chem, 2019;49(6):510-533.
    PMID: 30648398 DOI: 10.1080/10408347.2018.1561243
    The development of easy to use, rapid and sensitive methods for direct detection of foodborne bacterial pathogens has become significantly important due to their impact on human health. In recent years, carbon nanomaterials have been adapted in the fabrication of electrochemical biosensors due to their exceptional combination of intrinsic properties such as high conductivity, stability and biocompatibility that render them as a promising candidate for bio-sensing material. The scope of this review is to provide a brief history of the current methods and different types of electrochemical biosensors used for the detection of bacterial pathogens. We primarily focus on the recent progress and applications of graphene, carbon nanotubes and their derivatives in electrochemical biosensors for foodborne bacterial pathogens detection. Finally, the status and future prospects of carbon-based electrochemical biosensors are also reviewed and discussed.
    Matched MeSH terms: Biosensing Techniques
  19. Nadzirah S, Gopinath SCB, Parmin NA, Hamzah AA, Mohamed MA, Chang EY, et al.
    Crit Rev Anal Chem, 2020 Sep 30.
    PMID: 32997522 DOI: 10.1080/10408347.2020.1816447
    Biosensors operating based on electrical methods are being accelerated toward rapid and efficient detection that improve the performance of the device. Continuous study in nano- and material-sciences has led to the inflection with properties of nanomaterials that fit the trend parallel to the biosensor evolution. Advancements in technology that focuses on nano-hybrid are being used to develop biosensors with better detection strategies. In this sense, titanium dioxide (TiO2) nanomaterials have attracted extensive interest in the construction of electrical biosensors. The formation of TiO2 nano-hybrid as an electrical transducing material has revealed good results with high performance. The modification of the sensing portion with a combination (nano-hybrid form) of nanomaterials has produced excellent sensors in terms of stability, reproducibility, and enhanced sensitivity. This review highlights recent research advancements with functional TiO2 nano-hybrid materials, and their victorious story in the construction of electrical biosensors are discussed. Future research directions with commercialization of these devices and their extensive utilizations are also discussed.
    Matched MeSH terms: Biosensing Techniques
  20. Syamimi Haslan, Lee YH, Goh CT, Ling LT
    Sains Malaysiana, 2018;47:2027-2033.
    Biosensor optik berasaskan hemoglobin (Hb) terpegun pada mikrosfera poli(n-butil akrilat-co-N-akriloksisuksinimida)
    [poli(nBA-NAS)] telah dibangunkan bagi mengesan kepekatan ion nitrit (NO2
    -
    ). Kompleks HEM ferum dalam Hb
    memangkinkan tindak balas penurunan ion NO2
    -
    kepada nitrik oksida (NO) lalu bergabung dengan deoksihemoglobin
    (HbFe2+) membentuk kompleks ferum-nitrosil-hemoglobin (HbFe2+-NO) yang berwarna hijau kekuningan. Spektrofotometer
    pantulan gentian optik digunakan untuk memantau kepekatan ion NO2
    -
    secara kuantitatif berdasarkan perubahan warna
    Hb terpegun pada mikrosfera poliakrilat daripada perang kemerahan ke hijau kekuningan pada panjang gelombang
    pantulan maksimum 668 nm. Pencirian terhadap biosensor nitrit reflektometrik melibatkan ujian kesan pH, kesan
    kepekatan Hb, julat rangsangan linear, kebolehasilan, jangka hayat dan kesan gangguan ion telah dijalankan. Biosensor
    ion NO2
    - optik terbangun memaparkan julat linear dinamik daripada 5 hingga 50 mg mL-1 (R2
    =0.9894) pada pH7.0 dengan
    had pengesanan (LOD) sebanyak 3.3 mg mL-1 dan nilai sisihan piawai relatif (RSD) kebolehasilan biosensor sebanyak
    5.8%. Jangka hayat biosensor optik nitrit tersebut adalah selama 36 hari dan majoriti ion asing yang sering wujud
    bersama ion NO2
    - dalam sampel air semula jadi tidak menunjukkan kesan gangguan yang bererti terhadap penentuan
    ion NO2
    -
    menggunakan biosensor optik terbangun kecuali ion Hg2+, Ag+, Br-
    dan S2-.
    Matched MeSH terms: Biosensing Techniques
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links