Displaying publications 41 - 60 of 84 in total

Abstract:
Sort:
  1. Anuar K, Hamdan S
    Talanta, 1992 Dec;39(12):1653-6.
    PMID: 18965586
    A new lead(II) electrode has been constructed with poly(hydroxamic acid) (PHXA) as the active material and silicone rubber as the supporting material. The electrode gave near Nerstian response over the concentration range 4 x 10(-5)-1 x 10(-2)M lead(II). The detection limit of the electrode is approximately 4 x 10(-6)M and the electrode works well in the pH range 4.5-6.0. The response time was 50-120 sec over the whole concentration range and the electrode has a working life of at least 4 weeks. Iron(III) severely poisoned the electrode membrane. Nickel(II) and mercury(II) gave very strong interference compared to copper(II), silver(I), cobalt(II), sodium(I), potassium(I), zinc(II) and cadmium(II) which gave some or little interference. Values determined with atomic absorption (AAS) and a commercial lead(II) electrode were in good agreement with those measured with the lead(II) electrode reported here.
  2. Haron MJ, Wan Md ZW, Desa MZ, Kassim A
    Talanta, 1994 May;41(5):805-7.
    PMID: 18966002
    Poly(hydroxamic acid) chelating ion-exchange resin was prepared from crosslinked poly(methacrylate) beads. The starting polymer was prepared by a suspension polymerization of methacrylate and divinyl benzene. Conversion of the ester groups into the hydroxamic acid was carried out by treatment with hydroxylamine in an alkaline solution. Hydroxamic acid capacity of the product was 2.71 mmol/g. The resin exhibited high affinity towards Fe(III) and Pb ions and its capacities for Fe(III), Pb, Cu, Ni and Co ions were pH dependent. The ability of the resin to carry out the separation of Fe(III)CuCo/Ni and PbNi ions is also reported.
  3. Poh BL, Khairuddean M
    Talanta, 1996 Oct;43(10):1727-31.
    PMID: 18966659
    A non-cyclic tetrameric structure has been suggested for calcichrome (calcion). This structure is consistent with its mass spectrum, proton NMR spectrum, elemental composition and complexing ability with polyaromatic hydrocarbons in water. The stability constants of the 1:1 complexes formed between calcichrome and seven polyaromatic hydrocarbons in water at room temperature have been measured.
  4. Ahmad M, Narayanaswamy R
    Talanta, 1995 Sep;42(9):1337-44.
    PMID: 18966361
    Chrome azurol S immobilised on XAD-2 has been used in this study as a reagent phase for the development of an optical fibre Al(III) sensor. Using a kinetic approach, this sensor was able to give a linear response in the Al(III) concentration range of 1.3 x 10(-5)-2.0 x 10(-4) M with a limit of detection of 1.0 x 10(-4) M. The optimum responses were obtained at pH 6.0 and when the solution was stirred. The sensor response was found to have a repeatability and reproducibility of 1.6% and 5.8%, respectively. The results obtained for Al(III) determination in aqueous sample were in good agreement with those obtained using graphite furnace-atomic absorption spectrometry.
  5. Saleh MI, Ahmad M, Darus H
    Talanta, 1990 Jul;37(7):757-9.
    PMID: 18965016
    A series of chelating reagents, 1-phenyl-3-methyl-4-(2-fluorobenzoyl)-5-pyrazolone, 1-phenyl-3-methyl-4-(3-fluorobenzoyl)-5-pyrazolone and 1-phenyl-3-methyl-4-(4-fluorobenzoyl)-5-pyrazolone, has been synthesized. The extraction of Ln(III), (Ln = La, Eu and Lu) into chloroform with these reagents at 30 +/- 1 degrees has been studied. The composition of the complexes extracted has been determined by the slope method, and the extraction constants K(ex), were measured. The presence of the fluorine atom in the reagents does not make the K(ex), values much different from those obtained with the parent pyrazolone.
  6. Chong C
    Talanta, 1986 Jan;33(1):91-4.
    PMID: 18964038
    A simple atomic-absorption spectrophotometry method is described for the determination of silver, bismuth, cadmium, copper, iron, nickel and zinc in lead- and tin-base solders and white-metal bearing alloys, with use of a single sample solution. The sample is dissolved in a mixture of hydrobromic acid and bromine, then fumed with sulphuric acid. The lead sulphate is dissolved in concentrated hydrochloric acid. The method is particularly suitable for the determination of silver and bismuth, which are co-precipitated with lead sulphate. The other elements can also be determined after removal of the lead sulphate by filtration.
  7. Saad B, Kanapathy K, Ahmad MN, Hussin AH, Ismail Z
    Talanta, 1991 Dec;38(12):1399-402.
    PMID: 18965315
    Three main types of PVC solvent polymeric membrane ion-selective electrodes for chloroquine are described. They are based on three ion-pairing agents namely dipicrylamine (DPA), tetraphenylborate (TPB) or tetrakis(4-chlorophenyl)borate (TCPB) with either dioctylphenyl phosphonate (DOPP) or trioctyl phosphate (TOP) solvent mediator. All electrodes exhibit Nernstian responses, fast dynamic response times and a wide useful pH range. The best all-round electrode is based on TPB and TOP plasticizing solvent mediators with a limit of detection of 7.1 x 10(-6)M and was utilized for the assay of chloroquine in tablets. Direct potentiometric determinations with either the analyte addition method or the normal calibration method gave results comparable to the official method.
  8. Mohd Yusop AY, Xiao L, Fu S
    Talanta, 2019 Nov 01;204:36-43.
    PMID: 31357306 DOI: 10.1016/j.talanta.2019.05.078
    As a widely consumed beverage, coffee tends to be a target for intentional adulteration. This study describes the application of modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) coupled to liquid chromatography-high-resolution mass spectrometry (LC-HRMS) for simultaneous screening, identification, and quantification of undeclared phosphodiesterase 5 (PDE5) inhibitors in instant coffee premixes (ICPs). The mass spectrometer was operated in auto MS/MS acquisition for simultaneous MS and MS/MS experiments. Qualitative establishments from the suspected-target screening and targeted identification processes led to an unambiguous analyte assignment from the protonated molecule ([M+H]+) precursor ion which is subsequently used for quantification of 23 targeted PDE5 inhibitors. The analytical method validation covered specificity, linearity, range, accuracy, limit of detection (LOD), limit of quantification (LOQ), precisions, matrix effect (ME), and extraction recovery (RE). The specificity was established using the optimised chromatographic separation as well as the distinguishable [M+H]+ precursor ion. The linearity of each target analyte was demonstrated with a coefficient of determination (r2) of >0.9960 over the expected range of sample concentrations. The accuracy ranged from 88.1%-119.3% with LOD and LOQ of <70 ng/mL and 80 ng/mL, respectively. Excellent precisions were established within 0.4%-9.1% of the relative standard deviation. An insignificant ME within -5.2% to +8.7% was achieved using three different strategies of chromatography, sample extraction, and sample dilution. The RE was good for all target analytes within 84.7%-123.5% except for N-desethylacetildenafil at low (53.8%) and medium (65.1%) quality control levels. The method was successfully applied to 25 samples of ICPs where 17 of them were found to be adulterated with PDE5 inhibitors and their analogues. Further quantification revealed the total amount of these adulterants ranged from 2.77 to 121.64 mg per sachet.
  9. Mohd NI, Gopal K, Raoov M, Mohamad S, Yahaya N, Lim V, et al.
    Talanta, 2019 May 01;196:217-225.
    PMID: 30683354 DOI: 10.1016/j.talanta.2018.12.043
    The non-ionic silicone surfactant (OFX 0309) has been applied in cloud point extraction for the extraction of triazine herbicides in food samples. Evidence has shown that the non-ionic silicone surfactant demonstrated a good performance as an extractor toward triazine herbicides. In this present study, OFX 0309 surfactant was combined with activated charcoal (AC) due to their valuable properties. Activated charcoal modified with non-ionic silicone surfactant coated with magnetic nanoparticles (AC-OFX MNPs) was synthesized and characterized by FT-IR, VSM, SEM, TEM and BET. This novel material was applied as a magnetic adsorbent for the pre-concentration and separation of triazine herbicides due to hydrophobic interaction between polysiloxane polyether of OFX 0309 surfactant and triazine herbicides. Under optimal conditions, the proposed magnetic solid phase extraction method using AC-OFX MNPs adsorbent was applied to extract triazine herbicides from selected milk and rice samples using high performance liquid chromatography coupled with diode array detector. The validation method revealed a good linearity (1 - 500 μg L-1) with the coefficient of determination (R2) in the range of 0.992-0.998 for the samples. The limits of detection (LOD) of the developed method were 0.04 - 0.05 µg L-1 (milk sample) and 0.02 - 0.05 µg L-1 (rice sample). The limits of quantification (LOQ) were 0.134 - 0.176 µg L-1 (milk sample) and 0.075 - 0.159 µg L-1 (rice sample). The recoveries of the triazine compounds ranged from 81% to 109% in spiked milk samples and from 81% to 111% in spiked rice samples, with relative standard deviations (RSD) values lower than 13.5% and 12.1% for milk and rice samples, respectively. To the best of our knowledge, this is the first study that have investigated the use of magnetic nanoparticles coated activated charcoal modified with OFX 0309 surfactant for pretreatment of triazine herbicides in food samples analysis for simultaneous separation of organic pollutants.
  10. Taib M, Tan LL, Abd Karim NH, Ta GC, Heng LY, Khalid B
    Talanta, 2020 Jan 15;207:120321.
    PMID: 31594568 DOI: 10.1016/j.talanta.2019.120321
    An optical aptasensor-based sensing platform for rapid insulin detection was fabricated. Aminated porous silica microparticles (PSiMPs) were synthesized via a facile mini-emulsion method to provide large surface area for covalent immobilization of insulin-binding DNA aptamer (IGA3) by glutaraldehyde cross-linking protocol. A Nickel-salphen type complex with piperidine side chain [Ni(II)-SP] was synthesized with a simple one-pot reaction, and functionalized as an optical label due to strong π-π interaction between aromatic carbons of G-quadruplex DNA aptamer and planar aromatic groups of Ni(II)-SP to form the immobilized IGA3-Ni(II)-SP complex, i.e. the dye-labeled aptamer, thereby bringing yellow colouration to the immobilized G-quartet plane. Optical characterization of aptasensor towards insulin binding was carried out with a fiber optic reflectance spectrophotometer. The maximum reflectance intensity of the immobilized IGA3-Ni(II)-SP complex at 656 nm decreased upon binding with insulin as aptasensor changed to brownish orange colouration in the background. This allows optical detection of insulin as the colour change of aptasensor is dependent on the insulin concentration. The linear detection range of the aptasensor is obtained from 10 to 50 μIU mL-1 (R2 = 0.9757), which conformed to the normal fasting insulin levels in human with a limit of detection (LOD) at 3.71 μIU mL-1. The aptasensor showed fast response time of 40 min and long shelf life stability of >3 weeks. Insulin detection using healthy human serums with informed consent provided by participants suggests the DNA aptamer biosensor was in good agreement with ELISA standard method using BIOMATIK Human INS (Insulin) ELISA Kit.
  11. Khoo HT, Leow CH
    Talanta, 2021 Mar 01;224:121777.
    PMID: 33379011 DOI: 10.1016/j.talanta.2020.121777
    Fast and efficient separation remains a big challenge in high performance liquid chromatography (HPLC). The need for higher efficiency and resolution in separation is constantly in demand. To achieve that, columns developed are rapidly moving towards having smaller particle sizes and internal diameters (i.d.). However, these parameters will lead to high back-pressure in the system and will burden the pumps of the HPLC instrument. To address this limitation, monolithic columns, especially silica-based monolithic columns have been introduced. These columns are being widely investigated for fast and efficient separation of a wide range of molecules. The present article describes the current methods developed to enhance the column efficiency of particle packed columns and how silica monolithic columns can act as an alternative in overcoming the low permeability of particle packed columns. The fundamental processes behind the fabrication of the monolith including the starting materials and the silica sol-gel process will be discussed. Different monolith derivatization and end-capping processes will be further elaborated and followed by highlights of the performance such monolithic columns in key applications in different fields with various types of matrices.
  12. Citartan M, Tang TH
    Talanta, 2019 Jul 01;199:556-566.
    PMID: 30952298 DOI: 10.1016/j.talanta.2019.02.066
    Aptamers are nucleic acid-based molecular recognition elements that are specific and have high binding affinity against their respective targets. On account of their target recognition capacity, aptamers are widely utilized in a number of applications including diagnostics. This review aims to highlight the recent developments of aptasensors expedient for point-of-care (POC) diagnostics. Significant focus is given on the primary assay formats of aptamers such as fluorescence, electrochemical, surface plasmon resonance (SPR) and colorimetric assays. A potpourri of platforms such as paper-based device, lateral flow assay, portable electrodes, portable SPR and smart phones expedient for point-of-care (POC) diagnostics are discussed. Emphasis is also given on the technicalities and assay configurations associated with the sensors.
  13. Rozaini MNH, Semail NF, Saad B, Kamaruzaman S, Abdullah WN, Rahim NA, et al.
    Talanta, 2019 Jul 01;199:522-531.
    PMID: 30952293 DOI: 10.1016/j.talanta.2019.02.096
    Molecularly imprinted silica gel (MISG) was incorporated through dispersion in agarose polymer matrix to form a mixed matrix membrane (MMM) and was applied for the determination of three sulfonamide antibiotic compounds (i.e. sulfamethoxazole (SMX), sulfamonomethoxine (SMM), and sulfadiazine (SDZ)) from environmental water samples. Several important microextraction conditions, such as type of desorption solvent, extraction time, amount of sorbent, sample volume, pH, and effect of desorption time, were comprehensively optimized. A preconcentration factors of ≥ 20 was achieved by the extraction of 12.5 mL of water samples using the developed method. This microextraction-HPLC method demonstrated good linearity (1-500 μg L-1) with a coefficient of determination (R2) of 0.9959-0.9999, low limits of detection (0.06-0.17 μg L-1) and limits of quantification (0.20-0.56 μg L-1), good analyte recoveries (80-96%), and acceptable relative standard deviations (< 10%) under the optimized conditions. The method is systematically compared to those reported in the literature.
  14. Citartan M
    Talanta, 2021 Sep 01;232:122436.
    PMID: 34074421 DOI: 10.1016/j.talanta.2021.122436
    Dot blot assays have always been associated with antibodies as the main molecular recognition element, which are widely employed in a myriad of diagnostic applications. With the rising of aptamers as the equivalent molecular recognition elements of antibodies, dot blot assays are also one of the diagnostic avenues that should be scrutinized for their amenability with aptamers as the potential surrogates of antibodies. In this review, the stepwise procedures of an aptamer-based dot blot assays are underscored before reviewing the existing aptamer-based dot blot assays developed so far. Most of the applications center on monitoring the progress of SELEX and as the validatory assays to assess the potency of aptamer candidates. For the purpose of diagnostics, the current effort is still languid and as such possible suggestions to galvanize the move to spur the aptamer-based dot blot assays to a point-of-care arena are discussed.
  15. Wong SF, Low KH, Khor SM
    Talanta, 2020 Oct 01;218:121169.
    PMID: 32797922 DOI: 10.1016/j.talanta.2020.121169
    Food contamination is a serious concern because of a high level of chemicals in food causes severe health issues. Safeguarding the public from the risk of adulterated foods has become a challenging mission. Chloropropanols are of importance to food safety and food security because they are common chemical food contaminants and believed to be carcinogenic to humans. In chemical sensing, chloropropanols are challenging analytes owing to the lacking diversity of functional groups and difficulty in targeting the hydroxyl group in aqueous environments. Moreover, because of their small molecular size, the compositions of chloropropanols remain challenging for achieving chromatographic determination. Herein, to simulate human smell and taste sensations, serum albumins, which are protein-based receptors, were introduced as low-selective receptors for differential sensing. Utilizing serum albumins, a fluorophore (PRODAN), and an additive (ascorbic acid), a differential-based optical biosensor array was developed to detect and differentiate chloropropanols. By integrating the sensor array with linear discriminant analysis (LDA), four chloropropanols were effectively differentiated based on their isomerism properties and the number of the hydroxyl groups, even at ultra-low concentration (5 nM). This concentration is far below the maximum tolerable level of 0.18 μM for chloropropanols. The sensing array was then employed for chloropropanols differentiation and quantification in the complex mixtures (e.g., synthetic soy and dark soy sauces). Leave-one-out cross-validation (LOOCV) analysis demonstrated 100% accurate classification for all tests. These results signify our differential sensing array as a practical and powerful tool to speedily identify, differentiate, and even quantify chloropropanols in food matrices.
  16. Hu J, Yew CT, Chen X, Feng S, Yang Q, Wang S, et al.
    Talanta, 2017 Apr 01;165:419-428.
    PMID: 28153277 DOI: 10.1016/j.talanta.2016.12.086
    The identification and quantification of chemicals play a vital role in evaluation and surveillance of environmental health and safety. However, current techniques usually depend on costly equipment, professional staff, and/or essential infrastructure, limiting their accessibility. In this work, we develop paper-based capacitive sensors (PCSs) that allow simple, rapid identification and quantification of various chemicals from microliter size samples with the aid of a handheld multimeter. PCSs are low-cost parallel-plate capacitors (~$0.01 per sensor) assembled from layers of aluminum foil and filter paper via double-sided tape. The developed PCSs can identify different kinds of fluids (e.g., organic chemicals) and quantify diverse concentrations of substances (e.g., heavy metal ions) based on differences in dielectric properties, including capacitance, frequency spectrum, and dielectric loss tangent. The PCS-based method enables chemical identification and quantification to take place much cheaply, simply, and quickly at the point-of-care (POC), holding great promise for environmental monitoring in resource-limited settings.
  17. Leong CL
    Talanta, 1971 Aug;18(8):845-8.
    PMID: 18960953
    A ternary complex between germanium, Catechol Violet (CV) and cetyltrimethylanunoniuni bromide is proposed for the determination of germanium. The stoichiometric ratio Ge:CV is 1:2. Beer's law is obeyed from 0.1 to 1.0 ppm of Ge. The method is highly selective. Interference from Sn(IV), Fe(III), Bi(III), Cr(VI), Mo(VI), V(V) and Sb(III) in mg amounts is eliminated by extracting the germanium into carbon tetrachloride from 9M HC1 and then stripping into water before the photometric determination.
  18. Maulidiani M, Mediani A, Abas F, Park YS, Park YK, Kim YM, et al.
    Talanta, 2018 Jul 01;184:277-286.
    PMID: 29674043 DOI: 10.1016/j.talanta.2018.02.084
    Persimmon (Diospyros kaki L.) is one of the most important fruits that has been consumed for its medicinal properties due to the presence of some active metabolites, particularly polyphenols and carotenoids. Previously described methods, including HPLC, were limited in the determination of metabolites in different persimmon varieties. The present study shows the evaluation and the differences among persimmon polar and non-polar extracts by 1H NMR-based metabolomics approach. The hierarchical clustering analysis (HCA) based on score values of principal component analysis (PCA) model was used to analyze the important compounds in investigated fruits. The 1H NMR spectrum of persimmon chloroform (CDCl3) extracts showed different types of compounds as compared to polar methanol-water (CD3OD-D2O) ones. Persimmons growing in Israel were clustered different from those growing in Korea with the abundance of phenolic compounds (gallic, caffeic and protocathecuic acids), carotenoids (β-cryptoxanthin, lutein, and zeaxanthin), amino acids (alanine), maltose, uridine, and fatty acids (myristic and palmitoleic acids). Glucose, choline and formic acid were more prominent in persimmon growing in Korea. In CD3OD-D2O and CDCl3 persimmon extracts, 43 metabolites were identified. The metabolic differences were shown as well on the results of bioactivities and antioxidant capacities determined by ABTS, FRAP, CUPRAC and DPPH assays. The presented methods can be widely used for quantitation of multiple compounds in many plant and biological samples especially in vegetables and fruits.
  19. Shalash M, Makahleh A, Salhimi SM, Saad B
    Talanta, 2017 Nov 01;174:428-435.
    PMID: 28738603 DOI: 10.1016/j.talanta.2017.06.039
    A vortex-assisted liquid-liquid-liquid microextraction method followed by high performance liquid chromatography-diode array detection for the determination of fourteen phenolic acids (cinnamic, m-coumaric, chlorogenic, syringic, ferulic, o-coumaric, p-coumaric, vanillic, p-hydroxybenzoic, caffeic, 2, 4-dihydroxybenzoic, sinapic, gentisic and gallic acids) in honey, iced tea and canned coffee drink samples has been developed. The separation was achieved using a Poroshell 120-EC-C18 column under a gradient elution at a flow rate of 0.6mLmin-1 and mobile phase composed of methanol and acetic acid (1%, v/v). Under the optimum chromatographic conditions, the fourteen phenolic acids were separated in less than 32min. The extraction was performed using a small volume (400µL) of ternary organic solvents (1-pentanol, propyl acetate and 1-hexanol) dispersed into the aqueous sample (10mL) and assisted by vortex agitation (2500rpm for 45s), the analytes were next back-extracted from the organic solvent using 0.02M KOH (40µL) with vortex speed and time of 2500rpm and 60s, respectively. Under these conditions, enrichment factors of 30-193-fold were achieved. The limits of detection (LODs) were 0.05-0.68µgL-1. Recoveries in honey, iced tea and canned coffee drinks were in the range 72.2-112%. The method was successfully applied for the determination of the phenolic acids in honey, iced tea and canned coffee drinks.
  20. Azmer MI, Aziz F, Ahmad Z, Raza E, Najeeb MA, Fatima N, et al.
    Talanta, 2017 Nov 01;174:279-284.
    PMID: 28738579 DOI: 10.1016/j.talanta.2017.06.016
    This research work demonstrates compositional engineering of an organic-inorganic hybrid nano-composites for modifying absolute threshold of humidity sensors. Vanadyl-2,9,16,23-tetraphenoxy-29H,31H-phthalocyanine (VOPcPhO), an organic semiconductor, doped with Titanium-dioxide nanoparticles (TiO2NPs) has been employed to fabricate humidity sensors. The morphology of the VOPcPhO:TiO2nano-composite films has been analyzed by atomic force microscopy (AFM) and field emission scanning electron microscopy (FESEM). The sensors have been examined over a wide range of relative humidity i.e. 20-99% RH. The sensor with TiO2(90nm) shows reduced sensitivity-threshold and improved linearity. The VOPcPhO:TiO2(90nm) nano-composite film is comprised of uniformly distributed voids which makes the surface more favorable for adsorption of moisture content from environment. The VOPcPhO:TiO2nano-composite based sensor demonstrates remarkable improvement in the sensing parameter when equated with VOPcPhO sensors.
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links