Displaying publications 21 - 40 of 90 in total

Abstract:
Sort:
  1. Palaniappan R, Sundaraj K, Sundaraj S, Huliraj N, Revadi SS
    Clin Respir J, 2016 Jul;10(4):486-94.
    PMID: 25515741 DOI: 10.1111/crj.12250
    BACKGROUND: Monitoring respiration is important in several medical applications. One such application is respiratory rate monitoring in patients with sleep apnoea. The respiratory rate in patients with sleep apnoea disorder is irregular compared with the controls. Respiratory phase detection is required for a proper monitoring of respiration in patients with sleep apnoea.

    AIMS: To develop a model to detect the respiratory phases present in the pulmonary acoustic signals and to evaluate the performance of the model in detecting the respiratory phases.

    METHODS: Normalised averaged power spectral density for each frame and change in normalised averaged power spectral density between the adjacent frames were fuzzified and fuzzy rules were formulated. The fuzzy inference system (FIS) was developed with both Mamdani and Sugeno methods. To evaluate the performance of both Mamdani and Sugeno methods, correlation coefficient and root mean square error (RMSE) were calculated.

    RESULTS: In the correlation coefficient analysis in evaluating the fuzzy model using Mamdani and Sugeno method, the strength of the correlation was found to be r = 0.9892 and r = 0.9964, respectively. The RMSE for Mamdani and Sugeno methods are RMSE = 0.0853 and RMSE = 0.0817, respectively.

    CONCLUSION: The correlation coefficient and the RMSE of the proposed fuzzy models in detecting the respiratory phases reveals that Sugeno method performs better compared with the Mamdani method.

    Matched MeSH terms: Monitoring, Physiologic/methods
  2. Chan YK, Khan ZH
    Acta Anaesthesiol Taiwan, 2011 Dec;49(4):154-8.
    PMID: 22221689 DOI: 10.1016/j.aat.2011.11.002
    Hemodynamic monitoring provides us with refined details about the cardiovascular system. In spite of increased availability of the monitoring process and monitoring equipment, hemodynamic monitoring has not significantly improved survival outcome. Care providers should be cognizant of the role of the cardiovascular system and its importance in oxygen delivery to the cells in order to sustain life. Effective hemodynamic monitoring should be able to delineate how well the system is performing in carrying out this role. Different hemodynamic monitors serve in this role to a different extent; some provide very little information on this. The cardiovascular system is only one of the many systems that need to function optimally for survival; others of equal importance include the integrity of the airway, the breathing process, the adequacy of hemoglobin level, and the health of the tissue bed, especially in the brain and the heart. Advances in hemodynamic monitoring with focus on oxygen delivery at the cellular level may ultimately provide the edge to effective monitoring that can impact outcome.
    Matched MeSH terms: Monitoring, Physiologic*
  3. Manaf NA, Aziz MN, Ridzuan DS, Mohamad Salim MI, Wahab AA, Lai KW, et al.
    Med Biol Eng Comput, 2016 Jun;54(6):967-81.
    PMID: 27039402 DOI: 10.1007/s11517-016-1480-2
    Recently, there is an increasing interest in the use of local hyperthermia treatment for a variety of clinical applications. The desired therapeutic outcome in local hyperthermia treatment is achieved by raising the local temperature to surpass the tissue coagulation threshold, resulting in tissue necrosis. In oncology, local hyperthermia is used as an effective way to destroy cancerous tissues and is said to have the potential to replace conventional treatment regime like surgery, chemotherapy or radiotherapy. However, the inability to closely monitor temperature elevations from hyperthermia treatment in real time with high accuracy continues to limit its clinical applicability. Local hyperthermia treatment requires real-time monitoring system to observe the progression of the destroyed tissue during and after the treatment. Ultrasound is one of the modalities that have great potential for local hyperthermia monitoring, as it is non-ionizing, convenient and has relatively simple signal processing requirement compared to magnetic resonance imaging and computed tomography. In a two-dimensional ultrasound imaging system, changes in tissue microstructure during local hyperthermia treatment are observed in terms of pixel value analysis extracted from the ultrasound image itself. Although 2D ultrasound has shown to be the most widely used system for monitoring hyperthermia in ultrasound imaging family, 1D ultrasound on the other hand could offer a real-time monitoring and the method enables quantitative measurement to be conducted faster and with simpler measurement instrument. Therefore, this paper proposes a new local hyperthermia monitoring method that is based on one-dimensional ultrasound. Specifically, the study investigates the effect of ultrasound attenuation in normal and pathological breast tissue when the temperature in tissue is varied between 37 and 65 °C during local hyperthermia treatment. Besides that, the total protein content measurement was also conducted to investigate the relationship between attenuation and tissue denaturation level at different temperature ranges. The tissues were grouped according to their histology results, namely normal tissue with large predominance of cells (NPC), cancer tissue with large predominance of cells (CPC) and cancer with high collagen fiber content (CHF). The result shows that the attenuation coefficient of ultrasound measured following the local hyperthermia treatment increases with the increment of collagen fiber content in tissue as the CHF attenuated ultrasound at the highest rate, followed by NPC and CPC. Additionally, the attenuation increment is more pronounced at the temperature over 55 °C. This describes that the ultrasound wave experienced more energy loss when it propagates through a heated tissue as the tissue structure changes due to protein coagulation effect. Additionally, a significant increase in the sensitivity of attenuation to protein denaturation is also observed with the highest sensitivity obtained in monitoring NPC. Overall, it is concluded that one-dimensional ultrasound can be used as a monitoring method of local hyperthermia since its attenuation is very sensitive to the changes in tissue microstructure during hyperthermia.
    Matched MeSH terms: Monitoring, Physiologic*
  4. Khoo TH, Cardosa MS, Inbasegaran K
    Med J Malaysia, 1999 Mar;54(1):72-8.
    PMID: 10972008
    The Malaysian Society of Anaesthesiologists published a document entitled "Recommendations for Standards of Monitoring during Anaesthesia and Recovery" in 1993. This paper examines the results of two surveys, carried out in 1995 and 1996 respectively; to determine compliance with published Monitoring Standards in Malaysian public and private hospitals. In the private sector, compliance with the recommended standards during anaesthesia varied greatly. Of the 28 government hospitals surveyed in 1996, compliance with monitoring standards during anaesthesia was almost 100%. Standards in recovery areas were less than ideal. The majority of anaesthesiologists thought that the current recommended standards were adequate.
    Matched MeSH terms: Monitoring, Physiologic/standards*
  5. Ng KH
    Med J Malaysia, 1983 Dec;38(4):289-93.
    PMID: 6599984
    One of the important functions of the Coronary Care Unit (CCU) is the continuous and intensive monitoring of cardiac function. To date, many monitoring techniques have been developed and tested. In this paper, both the conventional and computerised monitoring techniques are reviewed and evaluated. It is shown that a computerised system has several defirute advantages over the conventional system, e.g. lower false alarm rate, accurate and fast data processing, retrospective studies. However one also ought to be aware of the limitations,
    Matched MeSH terms: Monitoring, Physiologic*
  6. Chowdhury MEH, Khandakar A, Alzoubi K, Mansoor S, M Tahir A, Reaz MBI, et al.
    Sensors (Basel), 2019 Jun 20;19(12).
    PMID: 31226869 DOI: 10.3390/s19122781
    One of the major causes of death all over the world is heart disease or cardiac dysfunction. These diseases could be identified easily with the variations in the sound produced due to the heart activity. These sophisticated auscultations need important clinical experience and concentrated listening skills. Therefore, there is an unmet need for a portable system for the early detection of cardiac illnesses. This paper proposes a prototype model of a smart digital-stethoscope system to monitor patient's heart sounds and diagnose any abnormality in a real-time manner. This system consists of two subsystems that communicate wirelessly using Bluetooth low energy technology: A portable digital stethoscope subsystem, and a computer-based decision-making subsystem. The portable subsystem captures the heart sounds of the patient, filters and digitizes, and sends the captured heart sounds to a personal computer wirelessly to visualize the heart sounds and for further processing to make a decision if the heart sounds are normal or abnormal. Twenty-seven t-domain, f-domain, and Mel frequency cepstral coefficients (MFCC) features were used to train a public database to identify the best-performing algorithm for classifying abnormal and normal heart sound (HS). The hyper parameter optimization, along with and without a feature reduction method, was tested to improve accuracy. The cost-adjusted optimized ensemble algorithm can produce 97% and 88% accuracy of classifying abnormal and normal HS, respectively.
    Matched MeSH terms: Monitoring, Physiologic*
  7. Mostafa SA, Mustapha A, Mohammed MA, Ahmad MS, Mahmoud MA
    Int J Med Inform, 2018 04;112:173-184.
    PMID: 29500017 DOI: 10.1016/j.ijmedinf.2018.02.001
    Autonomous agents are being widely used in many systems, such as ambient assisted-living systems, to perform tasks on behalf of humans. However, these systems usually operate in complex environments that entail uncertain, highly dynamic, or irregular workload. In such environments, autonomous agents tend to make decisions that lead to undesirable outcomes. In this paper, we propose a fuzzy-logic-based adjustable autonomy (FLAA) model to manage the autonomy of multi-agent systems that are operating in complex environments. This model aims to facilitate the autonomy management of agents and help them make competent autonomous decisions. The FLAA model employs fuzzy logic to quantitatively measure and distribute autonomy among several agents based on their performance. We implement and test this model in the Automated Elderly Movements Monitoring (AEMM-Care) system, which uses agents to monitor the daily movement activities of elderly users and perform fall detection and prevention tasks in a complex environment. The test results show that the FLAA model improves the accuracy and performance of these agents in detecting and preventing falls.
    Matched MeSH terms: Monitoring, Physiologic/methods*
  8. Palaniappan R, Sundaraj K, Sundaraj S
    Comput Methods Programs Biomed, 2017 Jul;145:67-72.
    PMID: 28552127 DOI: 10.1016/j.cmpb.2017.04.013
    BACKGROUND: The monitoring of the respiratory rate is vital in several medical conditions, including sleep apnea because patients with sleep apnea exhibit an irregular respiratory rate compared with controls. Therefore, monitoring the respiratory rate by detecting the different breath phases is crucial.

    OBJECTIVES: This study aimed to segment the breath cycles from pulmonary acoustic signals using the newly developed adaptive neuro-fuzzy inference system (ANFIS) based on breath phase detection and to subsequently evaluate the performance of the system.

    METHODS: The normalised averaged power spectral density for each segment was fuzzified, and a set of fuzzy rules was formulated. The ANFIS was developed to detect the breath phases and subsequently perform breath cycle segmentation. To evaluate the performance of the proposed method, the root mean square error (RMSE) and correlation coefficient values were calculated and analysed, and the proposed method was then validated using data collected at KIMS Hospital and the RALE standard dataset.

    RESULTS: The analysis of the correlation coefficient of the neuro-fuzzy model, which was performed to evaluate its performance, revealed a correlation strength of r = 0.9925, and the RMSE for the neuro-fuzzy model was found to equal 0.0069.

    CONCLUSION: The proposed neuro-fuzzy model performs better than the fuzzy inference system (FIS) in detecting the breath phases and segmenting the breath cycles and requires less rules than FIS.

    Matched MeSH terms: Monitoring, Physiologic/methods*
  9. Izneid BA, Fadhel MI, Al-Kharazi T, Ali M, Miloud S
    J Food Sci Technol, 2014 Nov;51(11):3244-52.
    PMID: 26396317 DOI: 10.1007/s13197-012-0880-z
    A portable infrared spectroscopy system has been designed and developed for assessment of quality of mango fruit. This paper describes the design and development of a fruit quality grading device using reflectance mode optical sensor. The experiment was conducted to obtain the best results from the system and the device was correlated according to the measured output. In the experiment, several samples of mango fruits have been monitored for six days to study the relation how fruit quality increases with time as fruit ripens. Between the unripe mango fruit and the ripest one, a range of 3.5 V to 4.2 V was measured by the developed system. The rate of quality increase was calculated as an average of 6.7 mV per day. These results were used to correlate the final hardware and software development of the device. The results demonstrate that, portable near infrared spectroscopy is feasible for evaluating mango quality non-destructively.
    Matched MeSH terms: Monitoring, Physiologic
  10. Tan I, Delilkan AE
    Med J Malaysia, 1993 Dec;48(4):381-91.
    PMID: 8183160
    Modern anaesthesia carries a definite although small risk. The risk from general and regional anaesthesia is reviewed, the causes explored, and preventive strategies discussed. Although anaesthesia may never be 100% safe, a knowledge of the risk and causes enables us to work towards this goal.
    Matched MeSH terms: Monitoring, Physiologic
  11. Alahnomi RA, Zakaria Z, Yussof ZM, Althuwayb AA, Alhegazi A, Alsariera H, et al.
    Sensors (Basel), 2021 Mar 24;21(7).
    PMID: 33804904 DOI: 10.3390/s21072267
    Recent developments in the field of microwave planar sensors have led to a renewed interest in industrial, chemical, biological and medical applications that are capable of performing real-time and non-invasive measurement of material properties. Among the plausible advantages of microwave planar sensors is that they have a compact size, a low cost and the ease of fabrication and integration compared to prevailing sensors. However, some of their main drawbacks can be considered that restrict their usage and limit the range of applications such as their sensitivity and selectivity. The development of high-sensitivity microwave planar sensors is required for highly accurate complex permittivity measurements to monitor the small variations among different material samples. Therefore, the purpose of this paper is to review recent research on the development of microwave planar sensors and further challenges of their sensitivity and selectivity. Furthermore, the techniques of the complex permittivity extraction (real and imaginary parts) are discussed based on the different approaches of mathematical models. The outcomes of this review may facilitate improvements of and an alternative solution for the enhancement of microwave planar sensors' normalized sensitivity for material characterization, especially in biochemical and beverage industry applications.
    Matched MeSH terms: Monitoring, Physiologic
  12. Mishu MK, Rokonuzzaman M, Pasupuleti J, Shakeri M, Rahman KS, Binzaid S, et al.
    Sensors (Basel), 2021 Apr 08;21(8).
    PMID: 33917665 DOI: 10.3390/s21082604
    In this paper, an integrated thermoelectric (TE) and photovoltaic (PV) hybrid energy harvesting system (HEHS) is proposed for self-powered internet of thing (IoT)-enabled wireless sensor networks (WSNs). The proposed system can run at a minimum of 0.8 V input voltage under indoor light illumination of at least 50 lux and a minimum temperature difference, ∆T = 5 °C. At the lowest illumination and temperature difference, the device can deliver 0.14 W of power. At the highest illumination of 200 lux and ∆T = 13 °C, the device can deliver 2.13 W. The developed HEHS can charge a 0.47 F, 5.5 V supercapacitor (SC) up to 4.12 V at the combined input voltage of 3.2 V within 17 s. In the absence of any energy sources, the designed device can back up the complete system for 92 s. The sensors can successfully send 39 data string to the webserver within this time at a two-second data transmission interval. A message queuing telemetry transport (MQTT) based IoT framework with a customised smartphone application 'MQTT dashboard' is developed and integrated with an ESP32 Wi-Fi module to transmit, store, and monitor the sensors data over time. This research, therefore, opens up new prospects for self-powered autonomous IoT sensor systems under fluctuating environments and energy harvesting regimes, however, utilising available atmospheric light and thermal energy.
    Matched MeSH terms: Monitoring, Physiologic
  13. Gill, Jesjeet Singh, Ahmad Hatim Sulaiman, Mohd Hussain Habil
    ASEAN Journal of Psychiatry, 2007;8(2):64-70.
    MyJurnal
    Objectives: To determine the best possible programme that suits our local setting, to determine the average dose required, and to determine possible problems that can arise from implementing such a programme locally and how best to address them. Methods: The inclusion criteria were those above 18, a positive urine test, the presence of a supportive carer and willing to engage in the programme. Methadone was initiated and observations relating to dose, adverse events, relationship with carers, work performance, crime and high risk behaviours were monitored for 18 weeks. Results: Two thirds of the 45 subjects completed the trial over the 18 week period. No significant adverse events occurred and improvement in relationship with carers and work performance were noted with reduction in crime and high risk behaviours. Conclusion: Methadone is a safe and effective drug that can be used in the local Malaysian setting.
    Matched MeSH terms: Monitoring, Physiologic
  14. Dahlan Mohd, Mahathir Mohamed
    MyJurnal
    Polymer blends of 60/40 NR/HDPE were prepared using Brabender PL2000 Plasticorder with 60g capacity. The blends were added with radiation-sensitive natural rubber (NR)-based compatibilizer, known as LENRA. They were irradiated with electron-beam radiation at various doses. The efficacy of the compatibilizer was monitored by measuring various properties of the blends such as physical and dynamic mechanical properties including morphological studies by electron microscopic technique. Early results show that the addition of LENRA improves the properties of the TPNR blends.
    Matched MeSH terms: Monitoring, Physiologic
  15. Ibrahim NFA, Sabani N, Johari S, Manaf AA, Wahab AA, Zakaria Z, et al.
    Sensors (Basel), 2022 Oct 10;22(19).
    PMID: 36236769 DOI: 10.3390/s22197670
    Sweat analysis offers non-invasive real-time on-body measurement for wearable sensors. However, there are still gaps in current developed sweat-sensing devices (SSDs) regarding the concerns of mixing fresh and old sweat and real-time measurement, which are the requirements to ensure accurate the measurement of wearable devices. This review paper discusses these limitations by aiding model designs, features, performance, and the device operation for exploring the SSDs used in different sweat collection tools, focusing on continuous and non-continuous flow sweat analysis. In addition, the paper also comprehensively presents various sweat biomarkers that have been explored by earlier works in order to broaden the use of non-invasive sweat samples in healthcare and related applications. This work also discusses the target analyte's response mechanism for different sweat compositions, categories of sweat collection devices, and recent advances in SSDs regarding optimal design, functionality, and performance.
    Matched MeSH terms: Monitoring, Physiologic
  16. Rahman NH, Tanaka H, Shin SD, Ng YY, Piyasuwankul T, Lin CH, et al.
    Int J Emerg Med, 2015;8:12.
    PMID: 25932052 DOI: 10.1186/s12245-015-0062-7
    One of the key principles in the recommended standards is that emergency medical service (EMS) providers should continuously monitor the quality and safety of their services. This requires service providers to implement performance monitoring using appropriate and relevant measures including key performance indicators. In Asia, EMS systems are at different developmental phases and maturity. This will create difficultly in benchmarking or assessing the quality of EMS performance across the region. An attempt was made to compare the EMS performance index based on the structure, process, and outcome analysis.
    Matched MeSH terms: Monitoring, Physiologic
  17. Ahamed NU, Sundaraj K, Poo TS
    Proc Inst Mech Eng H, 2013 Mar;227(3):262-74.
    PMID: 23662342
    This article describes the design of a robust, inexpensive, easy-to-use, small, and portable online electromyography acquisition system for monitoring electromyography signals during rehabilitation. This single-channel (one-muscle) system was connected via the universal serial bus port to a programmable Windows operating system handheld tablet personal computer for storage and analysis of the data by the end user. The raw electromyography signals were amplified in order to convert them to an observable scale. The inherent noise of 50 Hz (Malaysia) from power lines electromagnetic interference was then eliminated using a single-hybrid IC notch filter. These signals were sampled by a signal processing module and converted into 24-bit digital data. An algorithm was developed and programmed to transmit the digital data to the computer, where it was reassembled and displayed in the computer using software. Finally, the following device was furnished with the graphical user interface to display the online muscle strength streaming signal in a handheld tablet personal computer. This battery-operated system was tested on the biceps brachii muscles of 20 healthy subjects, and the results were compared to those obtained with a commercial single-channel (one-muscle) electromyography acquisition system. The results obtained using the developed device when compared to those obtained from a commercially available physiological signal monitoring system for activities involving muscle contractions were found to be comparable (the comparison of various statistical parameters) between male and female subjects. In addition, the key advantage of this developed system over the conventional desktop personal computer-based acquisition systems is its portability due to the use of a tablet personal computer in which the results are accessible graphically as well as stored in text (comma-separated value) form.
    Matched MeSH terms: Monitoring, Physiologic/instrumentation*; Monitoring, Physiologic/methods*
  18. Yang Y, Wei X, Zhang N, Zheng J, Chen X, Wen Q, et al.
    Nat Commun, 2021 08 12;12(1):4876.
    PMID: 34385436 DOI: 10.1038/s41467-021-25075-8
    While the printed circuit board (PCB) has been widely considered as the building block of integrated electronics, the world is switching to pursue new ways of merging integrated electronic circuits with textiles to create flexible and wearable devices. Herein, as an alternative for PCB, we described a non-printed integrated-circuit textile (NIT) for biomedical and theranostic application via a weaving method. All the devices are built as fibers or interlaced nodes and woven into a deformable textile integrated circuit. Built on an electrochemical gating principle, the fiber-woven-type transistors exhibit superior bending or stretching robustness, and were woven as a textile logical computing module to distinguish different emergencies. A fiber-type sweat sensor was woven with strain and light sensors fibers for simultaneously monitoring body health and the environment. With a photo-rechargeable energy textile based on a detailed power consumption analysis, the woven circuit textile is completely self-powered and capable of both wireless biomedical monitoring and early warning. The NIT could be used as a 24/7 private AI "nurse" for routine healthcare, diabetes monitoring, or emergencies such as hypoglycemia, metabolic alkalosis, and even COVID-19 patient care, a potential future on-body AI hardware and possibly a forerunner to fabric-like computers.
    Matched MeSH terms: Monitoring, Physiologic/instrumentation; Monitoring, Physiologic/methods
  19. Khalil SF, Mohktar MS, Ibrahim F
    Sensors (Basel), 2014;14(6):10895-928.
    PMID: 24949644 DOI: 10.3390/s140610895
    Bioimpedance analysis is a noninvasive, low cost and a commonly used approach for body composition measurements and assessment of clinical condition. There are a variety of methods applied for interpretation of measured bioimpedance data and a wide range of utilizations of bioimpedance in body composition estimation and evaluation of clinical status. This paper reviews the main concepts of bioimpedance measurement techniques including the frequency based, the allocation based, bioimpedance vector analysis and the real time bioimpedance analysis systems. Commonly used prediction equations for body composition assessment and influence of anthropometric measurements, gender, ethnic groups, postures, measurements protocols and electrode artifacts in estimated values are also discussed. In addition, this paper also contributes to the deliberations of bioimpedance analysis assessment of abnormal loss in lean body mass and unbalanced shift in body fluids and to the summary of diagnostic usage in different kinds of conditions such as cardiac, pulmonary, renal, and neural and infection diseases.
    Matched MeSH terms: Monitoring, Physiologic/instrumentation*; Monitoring, Physiologic/methods*
  20. Khan A, Khan M, Ahmed S, Abd Rahman MA, Khan M
    PLoS One, 2019;14(7):e0219459.
    PMID: 31314772 DOI: 10.1371/journal.pone.0219459
    Underwater sensor networks (UWSNs) are ad-hoc networks which are deployed at rivers, seas and oceans to explore and monitor the phenomena such as pollution control, seismic activities and petroleum mining etc. The sensor nodes of UWSNs have limited charging capabilities. UWSNs networks are generally operated under two deployment mechanisms i.e localization and non-localization based. However, in both the mechanisms, balanced energy utilization is a challenging issue. Inefficient usage of energy significantly affects stability period, packet delivery ratio, end-to-end delay, path loss and throughput of a network. To efficiently utilize and harvest energy, this paper present a novel scheme called EH-ARCUN (Energy Harvesting Analytical approach towards Reliability with Cooperation for UWSNs) based on cooperation with energy harvesting. The scheme employs Amplify-and-Forward (AF) technique at relay nodes for data forwarding and Fixed Combining Ratio (FCR) technique at destination node to select accurate signal. The proposed technique selects relay nodes among its neighbor nodes based on harvested energy level. Most cooperation-based UWSN routing techniques do not exhibit energy harvesting mechanism at the relay nodes. EH-ARCUN deploys piezoelectric energy harvesting at relay nodes to improve the working capabilities of sensors in UWSNs. The proposed scheme is an extension of our previously implemented routing scheme called ARCUN for UWSNs. Performance of the proposed scheme is compared with ARCUN and RACE (Reliability and Adaptive Cooperation for efficient Underwater sensor Networks) schemes in term of stability period, packet delivery ratio, network throughput and path loss. Extensive simulation results show that EH-ARCUN performs better than both previous schemes in terms of the considered parameters.
    Matched MeSH terms: Monitoring, Physiologic
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links